System type: centralized; Ventilation type: recuperator; Mounting: suspended; Mounting diameter: 200; heater; Air filters: F7; Max. noise level (dB): 59; Type of heat exchanger: plate; Heater type: electric afterheater; Heater power: 2000; EC fan; Power consumption in ventilation mode (W): 233
add to listmy lists
2VV HRDA1-050UXCBE75-EE1C-0A0
2VV HRDA1-050UXCBE75-EE1C-0A0
System type
centralized
Ventilation type
recuperator
Mounting
suspended
Mounting diameter
200 mm
Features
heater
Air filters
F7 / exhaust, F5 - supply /
Maximum air flow (recuperation)
535 m³/h
Maximum noise level
59 dB
Type of heat exchanger
plate
Heat exchanger efficiency
93 %
Heater type
electric afterheater
Heater power
2000 W / 1200+800W (preheater and afterheater) /
Remote control
/ electronic /
EC fan
Power consumption in ventilation mode
233 W
Mains voltage
230 V
Country of origin
Czechia
Dimensions
792x1022x629 mm
Weight
92 kg