Catalog   /   Climate, Heating, Water Heating   /   Heating & Cooling   /   Recuperators & Ventilation Recovery   /   ASPIRA

ASPIRA Ecocomfort 160 RF (AP19981S1)

Photos - Recuperator / Ventilation Recovery ASPIRA Ecocomfort 160 RF
Photos 4
Outdated Product
Wall-mounted supply and exhaust unit with heat recovery. The device is supposed to be mounted in walls with a thickness of 24 to 58 cm, and with the use of a special extension - up to 1 m. The angle of inclination towards the street should be 1.5 - 3 °. When operating in the recirculation mode with heat recovery, air flows pass through a ceramic heat exchanger inside the device, which restores the heat or cold contained in the outgoing air masses. Then they are returned to the supply air. The efficiency of the heat exchanger is about 90%. The EC fan in the ASPIRA Ecocomfort 160 RF design has three impeller rotation speeds with an air exchange capacity of 24 to 68 m³/h. From the standard remote control, it is supposed to adjust the fan speeds, turn on the automatic cycle adjustment mode acc...ording to the temperature sensor, activate the low-noise night mode of the recuperator. Additionally, the model is equipped with humidity and light sensors (the latter is needed for the Sleep function). The recuperator is designed to operate at outside air temperatures down to -20 °C.
add to listmy lists
ASPIRA Ecocomfort 160 RF
30 m³/h
68 m³/h
System type
decentralized
Ventilation type
recuperator
Mounting
wall
Mounting diameter
160 mm
Air filters
G3
Minimum air flow (recuperation)
24 m³/h
Maximum air flow (recuperation)
68 m³/h
Number of fan speeds
3
Minimum noise level
27 dB
Maximum noise level
38 dB
Type of heat exchanger
enthalpy
Heat exchanger material
ceramics
Heat exchanger efficiency
90 %
Minimum operating temperature
-20 °C
Remote control
EC fan
Power consumption in ventilation mode
6.6 W
Power consumption (reheater + ventilation)
6.6 W
Mains voltage
230 В
Minimum wall thickness
280 mm
Maximum wall thickness
520 mm
Decorative panel thickness
47 mm
Country of origin
Italy
Added to E-Catalog
October 2020
P/N
AP19981S1

Comes with a wireless remote control.

Wall-mounted supply and exhaust unit with heat recovery. The device is supposed to be mounted in walls with a thickness of 24 to 58 cm, and with the use of a special extension - up to 1 m. The angle of inclination towards the street should be 1.5 - 3 °. When operating in the recirculation mode with heat recovery, air flows pass through a ceramic heat exchanger inside the device, which restores the heat or cold contained in the outgoing air masses.

Then they are returned to the supply air. The efficiency of the heat exchanger is about 90%. The EC fan in the ASPIRA Ecocomfort 160 RF design has three impeller rotation speeds with an air exchange capacity of 24 to 68 m³/h. From the standard remote control, it is supposed to adjust the fan speeds, turn on the automatic cycle adjustment mode according to the temperature sensor, activate the low-noise night mode of the recuperator. Additionally, the model is equipped with humidity and light sensors (the latter is needed for the Sleep function). The recuperator is designed to operate at outside air temperatures down to -20 °C.

The information in the model description is for reference purposes.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog ASPIRA 2026 - new arrivals, bestsellers, and the most relevant models ASPIRA.
need a centralized ventilation system or already open the windows
26 May 2021 
So, they say this is the quietest thing on the market. If so, then I conclude that recuperators, in principle, cannot be used.
no merits
So, they have a cool feature that they synchronize with each other so that everyone does not blow IN or OUT of the house at the same time. This is good. But what is bad is that they cannot be controlled SEPARATELY. And they make noise, oh, how loud they make noise. In night mode, it is almost inaudible, but the air quality indicators are not too different from when there were none at all and all the windows were closed. In the first mode, it is noisy but tolerable, but the CO2 level is slowly but growing, they can not even cope with 1 person in the room. 2nd and 3rd speed is a helicopter and a turbojet, respectively. At the second speed, 1-2 people somewhere consume as much as they come in and CO2 does not increase and does not fall by 3 already falls. As a result, we have a situation, in one room a person wants to sleep, work or do anything, and in the other it is stuffy and the other wants to turn on the ventilation. And they cannot be controlled separately. As a result, either one listens to the helicopter under his ear or the other sits without ventilation. In addition to all of the above, the control panel deserves a separate description. If you just want to switch the mode, it will take a few minutes. Hold the I button until he wakes up, then he thinks for a long time and communicates with the base, then you can change the speed or mode, wait until they talk again for a long time and after that you can change the speed or mode again if you need to change this and that at a time ( as often happens).
Stepan Ordause ASPIRA Ecocomfort 160 RF less than month
Add Review