Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   UPS   /   RUCELF

RUCELF UPI-400-12-EL 400 VA

Photos - UPS RUCELF UPI-400-12-EL 400 VA
Outdated Product
Type: smart; Form factor: standard (Tower); Full load operating time (min): 7; Half load operating time (min): 14; Switching to battery (ms): 4; Input voltage: 1 phase (230V); Input voltage range (V): 140-270; Peak output power (VA): 400; Rated output power (W): 320; Output waveform: pure sine wave (PSW)
add to listmy lists
RUCELF UPI-400-12-EL 400 VA
Main
Typesmart
Form factorstandard (Tower)
Full load operating time7 min
Half load operating time14 min
Switching to battery4 ms
Input
Input voltage1 phase (230V)
Input voltage range140-270 В
Bypass (direct connection)in absent
Output
Output voltage1 phase (230V)
Peak output power400 VA
Rated output power320 W
Output voltage accuracy8 %
Output waveformpure sine wave (PSW)
Output frequency50 Hz
Redundant sockets1
Socket typetype F (Schuko)
Battery
Battery includedno battery
Battery(ies) connection to UPS12 В
External battery connection
Protection
Protectionoverload protection
sound alarm
Fusemelting
Control interfacesUSB type B
General
Screen
Operating temperature-15 – 55 °C
Dimensions (HxWxD)100x150x320 mm
Weight4.5 kg
Added to E-CatalogMarch 2014
The information in the model description is for reference purposes.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog RUCELF 2026 - new arrivals, bestsellers, and the most relevant models RUCELF.
Model overview based on user reviews  
The RUCELF UPI-400-12-EL 400 VA is an interactive UPS designed for reliable power backup with a pure sine wave output. It offers a full load operating time of 7 minutes and a half load operating time of 14 minutes, making it suitable for short-term power outages. The UPS features a fast switching time of 4 ms to battery mode, ensuring minimal disruption. Users appreciate its performance, noting it worked without problems for a year. However, the absence of a battery in the set and the lack of service support are significant drawbacks, as highlighted by a user who experienced a battery failure and found it difficult to repair. Despite its functionality, the UPS is considered expensive by some users.
Pros

Cons

good model, like it
18 November 2015 
I use a year. Worked without problems. However, the battery stopped working. I think that the cause of the breakdown was the battery that failed. No one knows where to repair the block
Service is missing.
use RUCELF UPI-400-12-EL month or more i recommend it should buy