Vulkan SCD8000 (34410)
![]() | Outdated Product Fuel: petrol; Output voltage: 230 B; Rated power (kW): 6; Max. power (kW): 6.5; Alternator: synchronous; Engine size (cm³): 499; Fuel consumption (50% load) (l/h): 2.57; Fuel tank volume (L): 18; Motor cooling: air; Total number of sockets: 2; automatic voltage regulator (AVR); display |
Vulkan SCD8000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The information in the model description is for reference purposes.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog Vulkan 2026 - new arrivals, bestsellers, and the most relevant models Vulkan.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog Vulkan 2026 - new arrivals, bestsellers, and the most relevant models Vulkan.

How to choose a backup power generatorKey points to consider when choosing your own stand-alone mini-power plant

How to connect a generator to a house: via an outlet, a switch, and an ATS unitThree ways to connect a backup power station to a household electrical grid
I bought in a hurry, as winter came and interruptions began, I bought with the expectation of a private house with a well, an electroctol, a boiler and all home care appliances. The reason for the purchase is rather that it was available, before that I bought myself a three-phase Honda for 7 kW, but alas, my well pump did not start on it, the pump is single-phase at 2.3 kilowatts, but at start-up it takes 5-6 kW for the share of the sikindu, and everything is just dull. The option was one replacement for a single-phase one, but it was all postponed until later ... and then it came quickly and took what was. In fact, I have been using it for a year already, it was 5-6 days a year when it worked for half a day, there is an auto-start from the battery, but there is also a jerk, but the auto-start here is hemorrhagic, the battery does not charge when the generator is running, that is, in fact, you need to have a charger to charge it at least once a year, it didn’t sit down for me in a year ... well, I understand that I need to do exercises so that he doesn’t just die. They write that there is an AVR, but in reality it is not, I have protection inside the house, and always one phase is loaded more than the others and protection against phase imbalance works, it’s not critical, but it doesn’t work, although it writes an equal voltage on the output in all three phases (this is already inside the house, the generator is single-phase.) It makes decent noise, but here you need to choose either light or noise))) He eats very decently, 2.5 liters per hour, I would even say more .... just by buying it I filled a full tank and already topped up 5 liters twice, the insole on the gas tank just falls before my eyes ... by the way, a three-phase Honda didn’t have this ... most likely the quality speaks for itself. Price with installation of mulsom, etc. turnkey cost me 1100 dollars, quite a lot ... But as my electricians say, he will walk no worse than a good Japanese .. let's see ... |
Add Review
Ask Question


























