Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Boilers   /   Wichlacz

Wichlacz GK 25 25 kW

Photos - Boiler Wichlacz GK 25 25 kW
Outdated Product
Energy source: solid fuel; Installation: floor; Type: single-circuit (heating only); Heating area (m²): 200; Long burning; Heat output (kW): 25; Coolant max. T (°C): 90; Efficiency (%): 89; Combustion chamber: open (atmospheric); Firebox size: Dimensions (mm): 1340x540x700; Weight (kg): 390
add to listmy lists
Wichlacz GK 25 25 kW
Energy source:solid fuel
Mount:floor, single-circuit
Boiler power:25 kW, area ~ 200 m²
Combustion chamber:open
All specifications
Specifications GK 25
Main
Energy sourcesolid fuel
Installationfloor
Typesingle-circuit (heating only)
Heating area200 m²
Long burning
Technical specs
Heat output25 kW
Power supply230 В
Power consumption80 W
Coolant max. T90 °С
Heating circuit max. pressure3 bar
Consumer specs
Circulation pump
Boiler specs
Efficiency89 %
Combustion chamberopen (atmospheric)
Connections
Central heating flowDN50
Central heating returnDN50
Safety
Safety systemswater overheating
More specs
Dimensions (HxWxD)1340x540x700 mm
Weight390 kg
Added to E-CatalogSeptember 2015
The information in the model description is for reference purposes.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog Wichlacz 2026 - new arrivals, bestsellers, and the most relevant models Wichlacz.
0
0
3
5
a long period of work on one portion and fuel economy
21 April 2016 
20-50% of the working time, the fuel in the boiler is in standby mode - in a state of smoldering - everything is not burning now. It burns gradually, layer by layer with the opening of a new level of holes with air.
Automation keeps the set water temperature at the Wichlacz outlet from 35 to 90 ° C with an accuracy of 1 degree
i would like a longer burn, 4-6 hours on firewood is not enough
use Wichlacz GK 25 month or more i recommend it should buy
boiler-bomb!
15 April 2016 
relatives from Uzbekistan called Shakhrisabz - they have very high-temperature coal and all the boilers for one winter and the grate burns out first of all - and the cast iron does not withstand
the principle of flowing grate is the bomb! Cast iron grate is resting!
want a longer burn time
use Wichlacz GK 17 month or more i recommend it should buy
anti-crisis boiler
14 April 2016 
burn any very foul coal
Gorinnya on one zavantazhenni 48 years
on firewood more like 4 years in me do not burn, that and that with a stretch
use Wichlacz GK 17 month or more i recommend it should buy
3 out of 8 user review(s) shown