APC Back-UPS 850VA BE850G2-RS 850 VA
Photos 4 | Outdated Product Type: back; Form factor: regular (extension); Full load operating time (min): 2.3; Half load operating time (min): 9.8; Switching to battery (ms): 6; Input voltage: 1 phase (230V); Input voltage range (V): 180 – 266; Peak output power (VA): 850; Rated output power (W): 520; Output waveform: similar to a sinusoid (approximated) |
APC Back-UPS 850VA BE850G2-RS 850 VA 650 VA 850 VA | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Before buying always check characteristics and configuration of product with online store manager
Catalog APC 2024 - new products, best sales and most actual models APC.
The name of the American brand APC and the emergency power supply of the connected equipment in the event of a failure of the main power source are identical concepts. To prove this, let's break down the ins and outs of the BE850G2-RS model.
Strong potential
A UPS with 520W of redundant power has a good potential among compact UPSs. Judge for yourself, with a power of 50-60 W, the device guarantees the preservation of the electrical performance of consumers for more than 1 hour. Where would it come in handy? For example, during this time you can use all the services of the router. With a “full parade”, the “uninterruptible” battery loses ground after 2 minutes. active load.
Onboard equipment
The main connection connectors in the on-board equipment of the APC Back-UPS 850VA BE850G2-RS are placed on the top panel of the case. Their category includes 8 euro sockets (6 for supplying backup power and 2 for operating in surge protector mode), USB-C and USB A ports for safely charging mobile gadgets, there are also lamps for indicating the remaining battery charge and on / off buttons for the device, along with turning off the buzzer.
Direct connection to PC
The UPS keeps a direct connection with the computer via a cord with RJ45/USB tails. The PowerChute Personal Edition proprietary utility allows you to fine-tune the voltage thresholds in the power grid, record the monthly electricity consumption, and show the cost of electricity spent. The only complaint about the model is the heap arrangement of some sockets, which sometimes makes it impossible to place large power supplies side by side. However, against the background of the general merits, this flaw does not make much of a difference. Moreover, two sockets in the design of the UPS are specially moved away from the others just for such a case.