United Kingdom
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Boilers   /   Saunier Duval

Saunier Duval Isotwin F30 H-MOD 29.6 kW
230 V

Photos - Boiler Saunier Duval Isotwin F30 H-MOD 29.6 kW 230 V
Outdated Product
$1,078.00 up to $1,328.16
Energy source: gas; Installation: wall; Type: dual-circuit (heating and DHW); Heating area (m²): 222; Heat output (kW): 29.6; Coolant min. T (°C): 38; Coolant max. T (°C): 80; DHW min. T (°C): 45; DHW max. T (°C): 65; Efficiency (%): 92.3; Combustion chamber: closed (turbocharged); Firebox size: Dimensions (mm): 890х600х499
add to listmy lists
Saunier Duval Isotwin F30 H-MOD 29.6 kW
230 V
Energy source:gas
Mount:wall, dual-circuit
Boiler power:29.6 kW, area ~ 222 m²
Combustion chamber:closed, flue 60/100 mm
DHW temperature:from 45 °С, before 65 °С
FAQ: 10 frequently asked questions about heating boilersAnswers to common questions in the section "heating boilers"
All specifications
Specifications Isotwin F30 H-MOD
Main
Energy sourcegas
Installationwall
Typedual-circuit (heating and DHW)
Heating area222 m²
Technical specs
Heat output29.6 kW
Power supply230 V
Power consumption189 W
Coolant min. T38 °С
Coolant max. T80 °С
Heating circuit max. pressure3 bar
DHW circuit max. pressure10 bar
Consumer specs
DHW min. T45 °С
DHW max. T65 °С
Performance (ΔT ~30 °C)20.3 L/min
Circulation pump
Boiler specs
Efficiency92.3 %
Combustion chamberclosed (turbocharged)
Flue diameter60/100 mm / 80/80 for split flue /
Inlet gas pressure20 mbar
Max. gas consumption3.44 m³/h
Expansion vessel capacity12 L
Expansion vessel pressure0.5 bar
Connections
Mains water intake1/2"
DHW flow1/2"
Gas supply3/4"
Central heating flow3/4"
Central heating return3/4"
Safety
Safety systemsgas pressure drop
water overheating
flame loss
draft control
power outage
water circulation failure
frost protection
More specs
Dimensions (HxWxD)890х600х499 mm
Weight62 kg
Added to E-Catalogmarch 2012
FAQ: 10 frequently asked questions about heating boilersAnswers to common questions in the section "heating boilers"
Information in model description is for reference purposes.
Before buying always check characteristics and configuration of product with online store manager
Catalog Saunier Duval 2024 - new products, best sales and most actual models Saunier Duval.
Additional features boiler Saunier Duval Isotwin F30 H-MOD:
  • H-MOD option allows power modulation from 15 to 100%
Model modification:
  • Isotwin F30 H-MOD Model — Closed Combustion
  • Isotwin C30 — open chamber

Filters
Models
(energy source) 
gas