Dark mode
United Kingdom
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   UPS

Comparison Logicpower LPY-B-PSW-500VA Plus 500 VA vs Logicpower LPY-PSW-500VA Plus 500 VA

Add to comparison
Logicpower LPY-B-PSW-500VA Plus 500 VA
Logicpower LPY-PSW-500VA Plus 500 VA
Logicpower LPY-B-PSW-500VA Plus 500 VALogicpower LPY-PSW-500VA Plus 500 VA
Outdated Product
from $87.00 up to $101.08
Outdated Product
TOP sellers
Typesmartsmart
Form factorstandard (Tower)standard (Tower)
Switching to battery4 ms3 ms
Input
Input voltage1 phase (230V)1 phase (230V)
Input voltage range140-275 V140-275 V
Max. current20 А
Bypass (direct connection)manualmanual
Output
Output voltage1 phase (230V)1 phase (230V)
Peak output power500 VA500 VA
Rated output power350 W350 W
Output voltage accuracy10 %3 %
Output waveformpure sine wave (PSW)pure sine wave (PSW)
Output frequency50-60 Hz50-60 Hz
Redundant sockets22
Socket typetype F (Schuko)type F (Schuko)
Battery
Battery in set
no battery
no battery
Battery(ies) connection to UPS12 V12 V
Min. charging current5 А5 А
Max. charging current10 А10 А
Charging current regulation
LiFePO4 charging support
Cold start
External battery connection
Protection
Protection
short circuit protection
overload protection
external battery overcharge protection
noise filtering
sound alarm
short circuit protection
overload protection
external battery overcharge protection
 
sound alarm
Fuseautoauto
General
Screen
Carrying handle
Operating temperature0 – 40 °C0 – 40 °C
Dimensions (HxWxD)225x145x340 mm180x145x230 mm
Weight5 kg3.9 kg
Added to E-Catalogjune 2018december 2015

Switching to battery

The time required to transfer the load from mains power to battery power. In standby and interactive UPSs (see Type), a short-term power failure occurs at this moment — accordingly, the shorter the time to switch to the battery, the more uniform the power supply is provided by the source during a power failure. Ideally, the switching time for the traditional 50 Hz AC frequency should be less than 5 ms (a quarter of one cycle of the sine wave). With inverter UPSs, the transfer time is, by definition, zero.

Max. current

The maximum current drawn by the UPS. In fact, the current reaches its maximum value only when the UPS is operating from the mains with maximum load power and a completely discharged battery. However, when calculating the load on the power grid, this parameter should be taken into account.

Output voltage accuracy

This parameter characterizes the degree of difference between the AC voltage at the output of the UPS and the perfect voltage, the graph of which has the shape of a regular sinusoid. The perfect voltage is so named because it is the most uniform and creates the least unnecessary load on the connected devices. Thus, the distortion of the output voltage is one of the most important parameters that determine the quality of the power received by the load. A distortion level of 0% means that the UPS produces a perfect sine wave, up to 5% — slight sine wave distortion, up to 18% — strong distortion, from 18% to 40% — a trapezoidal signal, more than 40% — a square wave.

Protection

The protection functions provided in the design of the UPS.

Short circuit protection. A short circuit is a sharp drop in load resistance to critically low values, due to which the current strength increases and the UPS experiences significant overloads that can disable the device and even cause a fire. It may be caused by a problem with the connected device, poor insulation, foreign objects, etc. In the event of such a situation, the short circuit protection system turns off the UPS, preventing unpleasant consequences.

Overload protection. Overload in this case is the excess of the load power consumption over the output power of the UPS. Working in this mode can also lead to unpleasant consequences up to breakage and fire; to avoid this, a protection system is installed that turns off the UPS when an overload occurs.

Overcharging protection of external battery. The overcharge protection function prevents the accumulation of excess energy in the battery, from which the UPS operates in autonomous mode. Overcharging is highly undesirable for any type of battery. It can lead to various unpleasant consequences - from deterioration in performance to overheating and fire of the battery. The automatic protective equipment on board the uninterruptible power supply turns off the power after the battery is fully charged. This prevents “extra” curre...nt from entering the battery, which could damage it. This system is convenient in that the battery can be left on charge for a long time without fear of overexerting it.

Noise filtering. A system that suppresses high-frequency interference in an electrical network — these can be either single voltage surges when turning on and off powerful electrical appliances, or long-term interference from constant sources, such as electric motors. These interferences can adversely affect the operation of electronics connected to the network (up to visible failures); the noise filtering system avoids this. Such systems are quite simple, and therefore most modern UPSs are equipped with them.

— Data line protection. High-frequency interference protection system, similar to interference filtering (see above) — only used not in an electrical network, but in a telephone or wired computer (LAN) network. Such networks are also subject to interference from various sources of electromagnetic radiation, which can cause failures of equipment connected to them: PCs, printers, fax machines, etc. UPSs with this feature have at least two LAN standard connectors (input and output), into which appropriate network or telephone (with RJ-11 connectors compatible with LAN) cables are inserted.

— Emergency cut-off. This connector allows you to connect the UPS to an emergency power off system. Thus, in an emergency (for example, in the event of a fire), the entire room, including and with a power reserve, can be completely de-energized by pressing one button. Without this, the UPS would simply switch to battery when the power goes out and leave the equipment energized, which could lead to disastrous consequences.

— Sound alarm. A system that gives an audible signal in various important situations. It is most commonly used to signal a power outage and the UPS is transferring to battery power. Without a sound signal, this could not be noticed at all (the light is not always on in the room, it goes out when the network fails, the contact in the socket itself may disappear, etc.), which is fraught with a sudden shutdown of the equipment, data loss and breakdowns. Also, sound alarm can be used for other events — low battery, end of charge, bypass on / off, etc.

Carrying handle

The presence of a handle on the UPS case, which makes it easy to move the device by hand. Most often, portable charging stations are equipped with a built-in handle, the very essence of which involves the mobile use of equipment.
Logicpower LPY-B-PSW-500VA Plus often compared
Logicpower LPY-PSW-500VA Plus often compared