United Kingdom
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   UPS

Comparison Marsriva KP2 Ultra vs Marsriva KP1 Ultra 30 VA

Add to comparison
Marsriva KP2 Ultra
Marsriva KP1 Ultra 30 VA
Marsriva KP2 UltraMarsriva KP1 Ultra 30 VA
Outdated ProductOutdated Product
TOP sellers
Main
Output connectors 1 x DC 9/12 V 1.5 A, 1 x DC 5 V 2.1 A, POE 24 V 0.75 A.
Output connectors 2 x DC 12 V 2.5 A, 1 x DC 9 V 2.5 A, 1 x DC 5 V 2.1 A.
Typelow voltage UPS (router, camera)low voltage UPS (router, camera)
Form factorstandard (flat)standard (flat)
Input
Input voltage1 phase (230V)1 phase (230V)
Input voltage range100 – 240 V100 – 240 V
Bypass (direct connection)is absentis absent
Output
Output voltageDC (constant voltage)DC (constant voltage)
Peak output power30 VA
Rated output power30 W30 W
Charging USB A ports
/5 H 2.4 A/
/5 H 2.4 A/
PoE output (LAN)24 H 1 A
Battery
Total battery capacity16 Ah16 Ah
Protection
Protection
short circuit protection
overload protection
short circuit protection
overload protection
General
Dimensions (HxWxD)32x173x108 mm32x108x173 mm
Weight0.51 kg0.5 kg
Added to E-Catalogoctober 2023october 2023

Peak output power

The maximum output power supplied by the UPS, in other words, the highest apparent load power allowed for this model.

This indicator is measured in volt-amperes (the general meaning of this unit is the same as that of the watt, and different names are used to separate different types of power). The total power consumption of the load, implied in this case, is the sum of two powers — active and reactive. Active power is actually effective power (it is indicated in watts in the characteristics of electrical appliances). Reactive power is the power wasted by coils and capacitors in AC devices; with numerous coils and/or capacitors, this power can be a fairly significant part of the total energy consumption. Note that for simple tasks, you can use data on effective power (it is often given for UPS — see below); but for accurate electrical calculations it is worth using the full one.

The simplest selection rule for this indicator is: the maximum output power of the UPS in volt-amperes should be at least 1.7 times higher than the total load power in watts. There are also more detailed calculation formulas that take into account the characteristics of different types of load; they can be found in special sources. As for specific values, the most modest modern UPSs give out 700 – 1000 VA, or even less — this is enough to power a PC of average performance; and in the most "heavyweight" models, th...is figure can be 8 – 10 kVA and higher.

PoE output (LAN)

Availability of a LAN connector in the UPS with support for PoE (Power over Ethernet) power supply. This technology allows energy to be transmitted via an Ethernet cable to power network devices. It is possible to power such devices directly from the UPS, which ensures equipment backup in case of power supply interruptions. Such devices include IP video surveillance cameras, access points, various sensors, etc.
Marsriva KP2 Ultra often compared