United Kingdom
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Boilers

Comparison Protherm Gepard 23 MOV 23 kW vs BAXI Eco Four 24 i 24 kW
230 V

Add to comparison
Protherm Gepard 23 MOV 23 kW
BAXI Eco Four 24 i 24 kW 230 V
Protherm Gepard 23 MOV 23 kWBAXI Eco Four 24 i 24 kW
230 V
from $501.83 up to $556.06
Outdated Product
from $589.80 up to $769.12
Outdated Product
TOP sellers
Main
Copper heat exchanger of the heating circuit with large cross-section tubes. 2-stage circulation pump. Integrated eBus communication system. Possibility to work with a room thermostat and with an outside temperature sensor.
Energy sourcegasgas
Installationwallwall
Typedual-circuit (heating and DHW)dual-circuit (heating and DHW)
Heating area184 m²180 m²
Technical specs
Heat output23 kW24 kW
Min. heat output9.1 kW9.3 kW
Power supply230 V230 V
Power consumption92 W80 W
Coolant min. T38 °С30 °С
Coolant max. T83 °С85 °С
Heating circuit max. pressure3 bar
DHW circuit max. pressure10 bar8 bar
Consumer specs
DHW min. T38 °С35 °С
DHW max. T65 °С60 °С
Performance (ΔT=25°C)13.7 L/min
Performance (ΔT ~30 °C)11.4 L/min
"Summer" mode
Heated floor mode
Circulation pump
Control buseBus
Boiler specs
Efficiency89.5 %91.2 %
Combustion chamberopen (atmospheric)open (atmospheric)
Flue diameter126 mm120 mm
Inlet gas pressure20 mbar20 mbar
Max. gas consumption2.9 m³/h
Expansion vessel capacity5 L6 L
Expansion vessel pressure3 bar0.5 bar
Heat exchangercopper
Connections
Mains water intake1/2"
DHW flow1/2"
Gas supply3/4"
Central heating flow3/4"
Central heating return3/4"
Safety
Safety systems
gas pressure drop
water overheating
flame loss
draft control
 
 
frost protection
gas pressure drop
water overheating
flame loss
draft control
power outage
water circulation failure
frost protection
More specs
Dimensions (HxWxD)740x410x310 mm730x400x299 mm
Weight33 kg29 kg
Added to E-Catalogjuly 2011november 2010

Heating area

The maximum area of the building that the boiler can effectively heat. However, it is worth considering that different buildings have different thermal insulation properties and modern buildings are much “warmer” than 30-year-old and even more so 50-year-old houses. Accordingly, this paragraph is more of a reference nature and does not allow a full assessment of the actual heated area. There is a formula by which you can derive the maximum heating area, knowing the useful power of the boiler and the climatic conditions in which it will be used; see Heat output for more details. In our case, the heating area is calculated according to the formula "boiler power multiplied by 8", which is approximately equivalent to use in houses that are more than a dozen years old.

Heat output

It is the maximum useful power of the boiler.

The ability of the device to heat a room of a particular area directly depends on this parameter; by power, you can approximately determine the heating area, if this parameter is not indicated in the specs. The most general rule says that for a dwelling with a ceiling height of 2.5 – 3 m, at least 100 W of heat power is needed to heat 1 m2 of area. There are also more detailed calculation methods that take into account specific factors: the climatic zone, heat gain from the outside, design features of the heating system, etc.; they are described in detail in special sources. Also note that in dual-circuit boilers (see "Type"), part of the heat generated is used to heat water for the hot water supply; this must be taken into account when evaluating the output power.

It is believed that boilers with a power of more than 30 kW must be installed in separate rooms (boiler rooms).

Min. heat output

The minimum heat output at which the heating boiler can operate in constant mode. Operation at minimum power allows you to reduce the number of on-and-off cycles that adversely affect the durability of heating boilers.

Power consumption

The maximum electrical power consumed by the boiler during operation. For non-electric models (see Energy source), this power is usually low, as it is required mainly for control circuits and it can be ignored. Regarding electric boilers, it is worth noting that the power consumption in them is most often somewhat higher than the useful one since part of the energy is inevitably dissipated and not used for heating. Accordingly, the ratio of useful and consumed power can be used to evaluate the efficiency of such a boiler.

Coolant min. T

The minimum operating temperature of the heat medium in the boiler system when operating in heating mode.

Coolant max. T

The maximum operating temperature of the heat medium in the boiler system when operating in heating mode.

Heating circuit max. pressure

The maximum pressure in the heating circuit of the boiler, at which it remains operational, and there is no risk of physical damage to the structure. For a heating system, the maximum pressure is usually about 3 bar, and for a domestic hot water circuit up to 10 bar. When the maximum pressure is exceeded, a safety valve is activated, and part of the water is discharged from the system until a normal pressure level is reached.

DHW circuit max. pressure

The maximum pressure in the hot water circuit (DHW) at which it can operate for a long time without failures and damage. See "Heating circuit maximum pressure".

DHW min. T

The minimum temperature of domestic hot water (DHW) supplied by a dual-circuit boiler. For comparison, we note that water begins to be perceived as warm, starting from 40 °C, and in centralized hot water supply systems, the temperature of hot water is usually about 60 °C (and should not exceed 75 °C). At the same time, in some boilers, the minimum heating temperature can be only 10 °C or even 5 °C. A similar mode of operation is used to protect pipes from freezing during the cold season: the circulation of water with a positive temperature prevents the formation of ice inside and damage to the circuits.

It is also worth keeping in mind that when heated to a given temperature, the temperature difference ("ΔT") may be different — depending on the initial temperature of the cold water. And the performance of the boiler in the DHW mode directly depends on ΔT; see below for performance details.
Protherm Gepard 23 MOV often compared
BAXI Eco Four 24 i often compared