Comparison Thermex SKIF 5-12 Wi-Fi 12 kW
230 V / 400 V
vs Thermex GRIZZLY 5-12 Wi-Fi 12 kW
230 V / 400 V

Add to comparison
Thermex SKIF 5-12 Wi-Fi 12 kW 230 V / 400 V
Thermex GRIZZLY 5-12 Wi-Fi 12 kW 230 V / 400 V
Thermex SKIF 5-12 Wi-Fi 12 kW
230 V / 400 V
Thermex GRIZZLY 5-12 Wi-Fi 12 kW
230 V / 400 V
Outdated ProductOutdated Product
TOP sellers
Main
4 power levels. Compatible with heated floors. Programmer. Wi-Fi. Alice's support. Power supply 230 / 400 V. Operation from a generator. Aluminium-magnesium heat exchanger.
Energy sourceelectricityelectricity
Installationwallwall
Typedual-circuit (heating and DHW)single-circuit (heating only)
Heating area96 m²96 m²
Technical specs
Heat output12 kW12 kW
Min. heat output5 kW5 kW
Power supply230 V / 400 V230 V / 400 V
Rated current54.5 А
Coolant min. T30 °С30 °С
Coolant max. T
85 °С /60°C for underfloor heating/
85 °С /60°C for underfloor heating/
Heating circuit max. pressure3 bar3 bar
Consumer specs
Wi-Fi
Heated floor mode
Circulation pump
Programmable thermostat
Boiler specs
Combustion chamberno chamberno chamber
Expansion vessel capacity6 L6 L
Connections
Central heating flow3/4"3/4"
Central heating return3/4"3/4"
Safety
Safety systems
water overheating
water circulation failure
frost protection
water overheating
water circulation failure
frost protection
More specs
Dimensions (HxWxD)600x390x239 mm600x390x239 mm
Weight21.5 kg21.5 kg
Added to E-Catalogjuly 2022july 2020

Type

Depending on the set of functions, boilers are divided into single-circuit and dual-circuit.

- Single-circuit boilers are equipped with one heat exchanger, in which the heat from fuel combustion is transferred to the heat medium of the heating system. The only function of such boilers is space heating. It is technically possible to use single-circuit boilers to provide hot water, but this requires an additional tank (the so-called indirect water heater).

- In dual-circuit boilers, the primary heat exchanger is supplemented by a secondary one. Due to this, such a boiler, in addition to heating the room, also provides a hot water supply. In this case, both running water and water accumulated in a special tank(see Built-in water heater tank) can be used.

Rated current

The current consumed by the electric boiler (see "Power source") during normal operation.

This parameter directly depends on the power. It is required primarily for organizing the connection: wiring and automation must safely deal with the current consumed by the unit.