Grunhelm GEB4-12E 12 kW 230 V / 400 V
Thermex SKIF 5-12 Wi-Fi 12 kW 230 V / 400 V
Grunhelm GEB4-12E 12 kW
230 V / 400 V
Thermex SKIF 5-12 Wi-Fi 12 kW
230 V / 400 V
Expecting restockOutdated Product
TOP sellers
Main
4 power levels. Compatible with heated floors. Programmer. Wi-Fi. Alice's support. Power supply 230 / 400 V. Operation from a generator. Aluminium-magnesium heat exchanger.
Energy sourceelectricityelectricity
Installationwallwall
Typedual-circuit (heating and DHW)dual-circuit (heating and DHW)
Heating area96 m²96 m²
Technical specs
Heat output12 kW12 kW
Min. heat output5 kW
Power supply230 V / 400 V230 V / 400 V
Coolant min. T30 °С
Coolant max. T
85 °С /60°C for underfloor heating/
Heating circuit max. pressure3 bar
Consumer specs
Wi-Fi
"Summer" mode
Heated floor mode
Circulation pump
Programmable thermostat
Boiler specs
Combustion chamberno chamberno chamber
Expansion vessel capacity6 L6 L
Connections
Central heating flow3/4"
Central heating return3/4"
Safety
Safety systems
water overheating
 
frost protection
water overheating
water circulation failure
frost protection
More specs
Dimensions (HxWxD)600x390x236 mm600x390x239 mm
Weight21.5 kg
Added to E-Catalogmarch 2023july 2022

Min. heat output

The minimum heat output at which the heating boiler can operate in constant mode. Operation at minimum power allows you to reduce the number of on-and-off cycles that adversely affect the durability of heating boilers.

Coolant min. T

The minimum operating temperature of the heat medium in the boiler system when operating in heating mode.

Coolant max. T

The maximum operating temperature of the heat medium in the boiler system when operating in heating mode.

Heating circuit max. pressure

The maximum pressure in the heating circuit of the boiler, at which it remains operational, and there is no risk of physical damage to the structure. For a heating system, the maximum pressure is usually about 3 bar, and for a domestic hot water circuit up to 10 bar. When the maximum pressure is exceeded, a safety valve is activated, and part of the water is discharged from the system until a normal pressure level is reached.

Wi-Fi

The boiler has a Wi-Fi module. This function is often used to remotely control the unit from a smartphone, tablet or other device. The specific features of such control may be different: for some models, you need to install a special application, for others, control is available through a page in any browser; the gadget can be connected directly or via the Internet, etc. The details of using Wi-Fi in each case should be clarified separately. Note that through such a communication channel, you can not only control the unit but also receive notifications from it — about the operating mode and parameters, about the current state, about failures and malfunctions, etc. At the same time, this function is relatively rare. In most cases, traditional control is sufficient.

"Summer" mode

It is an operating mode designed for the warm season. In this mode, it works only to provide domestic hot water, and the heating is turned off. If the boiler is equipped with an outside temperature sensor, this sensor is also switched off in summer mode so that the heating does not turn on at night when the outside temperature drops.

Programmable thermostat

The presence of a programmable thermostat in the design of the boiler.

Programmable thermostat is a device that allows not only to maintain the temperature but also to programme the operation of the boiler for a certain time. The simplest programmable thermostats cover a day, and more advanced ones allow you to set the operating mode for individual days of the week. Anyway, this function provides additional convenience and eliminates the need to adjust the operation of the boiler manually. On the other hand, the presence of a programmable thermostat affects the cost.

Central heating flow

The diameter of the pipe for connecting the pipe through which the heated water enters the heating system from the boiler.

Diameters are indicated in inches. In some cases, it is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size. Among which models stand out for 3/4", 1", 1 1/4" and 1 1/2".

Central heating return

The diameter of the pipe for connecting the pipe through which the cooled water returns from the heating system to the boiler.

Diameters are indicated in inches. In some cases, it is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size.