Dark mode
United Kingdom
Catalog   /   Small Appliances   /   Health & Rehabilitation   /   Blood Pressure Monitors

Comparison Omron M4 Intelli IT vs Omron M7

Add to comparison
Omron M4 Intelli IT
Omron M7
Omron M4 Intelli ITOmron M7
Compare prices 7Compare prices 2
TOP sellers
Typeautoauto
Place of measurementshouldershoulder
Power sourcebatteries / mainsbatteries / mains
Batteries4xAA
Battery indicator
Device dimensions105х85х152 mm165x73x110 mm
Specs
Pressure measuring range0 – 299 mmHg
Pulse measurement range40 – 180 bpm
Cuff dimensions22 – 42 cm22 – 42 cm
Memory2 persons
Recording readings60 pcs90 pcs
Features
Functions
pulse measurement
determination of arrhythmia
medium pressure calculation
measurement error signal
 
Bluetooth
pulse measurement
determination of arrhythmia
medium pressure calculation
measurement error signal
auto switch-off
 
In box
cover / case
batteries
 
 
Added to E-Catalogfebruary 2020april 2013

Batteries

The type of batteries used in blood pressure monitors.

— AA. One of the most common types of batteries today. Voltage — 1.5 V. One of the main advantages of this type of power supply is availability: AA batteries are sold almost everywhere where any batteries are sold at all.

— AAA. A kind of reduced analogue of AA batteries (see above) with the same operating voltage of 1.5 V. AAA batteries are also very common, and the dimensions allow them to be used in more compact devices.

Pressure measuring range

The effective measurement range of a blood pressure monitor covers both "upper" and "lower" pressure values. Most modern devices have a lower limit within 0-20 mm Hg, which is adequate for the majority of cases. As for the upper limit, a device with a maximum value of 180 mm Hg is generally sufficient for individuals without a history of significant blood pressure spikes until old age or without serious illnesses. However, for those prone to substantial increases, it's advisable to consider devices with higher upper limit values, which can reach up to 280 mm Hg in modern blood pressure monitors.

Pulse measurement range

The blood pressure monitor's pulse rate measurement capability typically falls within a range of 30-40 to 180 beats per minute. While extending the lower limit is unnecessary for household blood pressure monitors, a higher upper limit may be essential for measurements during intense physical activity or for individuals with conditions causing significant heart rate acceleration, such as tachycardia.

Memory

The number of users that can be stored in the device's memory.

Blood pressure moitors with such capabilities are capable of at least storing data for several measurements for each user, which makes it possible not to get confused in the readings if several people use the device. At the same time, a guest mode is also provided so that the measurement made is not wedged into your list.

Recording readings

The number of results that can be simultaneously stored in the blood pressure monitor's memory. The ability to store several results in memory can be useful, for example, to compare pressure readings in the morning, afternoon and evening — these results do not have to be manually recorded or memorized.

Functions

Pulse measurement. The ability to use a blood pressure monitor to measure heart rate (pulse). This frequency, along with blood pressure, is one of the most important indicators of the state of the cardiovascular system.

Determination of arrhythmia. Blood pressure monitors with this feature are able to track irregularities in the heartbeat (arrhythmia) — one of the important signals of health problems — and warn the user about it.

Medium pressure calculation. This function allows you to automatically calculate the average pressure based on several consecutive measurements.

Signal about measurement errors. Blood pressure monitors with this function are able to display error signals that can affect the accuracy of measurements — such as incorrect cuff application, air leakage from it, movement during measurement, device electronics failure, etc.

Auto switch-off. Most semi-automatic and automatic models of blood pressure monitors are able to automatically turn off after a few minutes of inactivity. This saves battery power.

Synchronization with PC. In this case, a wired connection is implied, not Bluetooth. Synchronization of the blood pressure monitor with a PC allows you to track...all the measurement results in one table (in some models — even with the date and time), save the results to the PC, freeing up the device's memory, select measurements for calculating the average pressure, etc.

— Bluetooth. The presence of wireless data transfer technology allows you to use the features described in the paragraph "Synchronization with a PC" by connecting to a smartphone and using a special application. This method is more mobile, easier and faster.

Voicing the measurements. Such blood pressure monitors are able not only to display the measurement results on the screen, but also to voice them, which can be very useful for elderly people with poor eyesight.

— Date and time indication. Having the ability to display the current date and time is useful for recording blood pressure measurements and tracking them over time. Blood pressure monitors equipped with a clock and calendar feature can automatically store measured pressure results in memory, associating them with specific date and time stamps when there is a recording mode.

WHO colour scale. The World Health Organization has established standards defining normal, low, or elevated blood pressure values. These standards incorporate a color scale that, after each measurement, aids in assessing the pressure status and determining appropriate actions. It's important to note that individual variations exist, and what constitutes normal pressure differs for each person. Therefore, these standards are generally advisory, providing guidance rather than prescribing specific actions.

In box

Additional cuff. The blood pressure monitor set includes two cuffs, main and auxiliary, which differ from each other only in standard size. Usually, the auxiliary cuff has a longer length. For example, if the length of the main cuff is 22-36 cm, then the auxiliary cuff will be one size larger, that is, 30-42 cm. An additional larger cuff allows you to expand the circle of users of the blood pressure monitor.

Power source. Blood pressure monitors with a power supply option can operate using a 230 V household power supply, eliminating the need for frequent battery replacements. Interestingly, many of these monitors also come equipped with batteries, providing users flexibility in choosing the power source for the measuring device.

Cover/case. The blood pressure monitor comes with a dedicated bag for convenient storage and transportation of all its components. Depending on the tonometer's configuration, the case can accommodate the device, primary and auxiliary cuffs, a stethoscope, spare batteries, a power supply, and instructions. Some cases even include an extra compartment for storing medications. Typically, the tonometer bag is soft.

— Batteries. The blood pressure monitor operates on replaceable batteries, commonly using AA or AAA batteries. This battery-powered design makes the device self-contained, allowing its use in remo...te locations or while traveling without access to a household electrical outlet. However, a drawback of battery-powered blood pressure monitors is the requirement for regular battery replacement or recharging.
Omron M4 Intelli IT often compared
Omron M7 often compared