Dark mode
United Kingdom
Catalog   /   Computing   /   Components   /   Computer Cooling

Comparison NZXT Kraken 360 vs NZXT Kraken X73

Add to comparison
NZXT Kraken 360
NZXT Kraken X73
NZXT Kraken 360NZXT Kraken X73
Compare prices 6
from £286.99 
Expecting restock
TOP sellers
Main specs
Featuresfor CPUfor CPU
Product typeliquid coolingliquid cooling
Fan
Number of fans33
Fan size120 mm120 mm
Fan thickness26 mm
Bearinghydrodynamichydrodynamic
Min. RPM500 rpm500 rpm
Max. RPM2000 rpm2000 rpm
Speed controllerauto (PWM)auto (PWM)
Max. air flow78.02 CFM73.11 CFM
Static pressure2.7 mm H2O2.93 mm H2O
MTBF60 K hours60 K hours
replaceable
Min noise level18 dB21 dB
Noise level31 dB36 dB
Power source4-pin4-pin
Radiator
Heatsink materialaluminiumaluminium
Plate materialcoppercopper
Socket
AMD AM4
AMD AM5
AMD TR4/TRX4
Intel 1150
Intel 1155/1156
 
 
 
Intel 1151 / 1151 v2
Intel 1200
Intel 1700 / 1851
AMD AM4
 
AMD TR4/TRX4
Intel 1150
Intel 1155/1156
Intel 1366
Intel 2011 / 2011 v3
Intel 2066
Intel 1151 / 1151 v2
Intel 1200
 
Liquid cooling system
Heatsink size360 mm360 mm
Pump size75x75x56 mm80x80x55 mm
Pump rotation speed2800 rpm2800 rpm
Pipe length400 mm400 mm
Pump power source4-pin
General
Display
Mount typebilateral (backplate)bilateral (backplate)
Manufacturer's warranty6 years6 years
Dimensions394x121x27 mm394x121x27 mm
Weight2210 g
Added to E-Catalogmay 2023january 2020

Fan thickness

This parameter must be considered in the context of whether the fan will fit into the computer case. Standard case fans are available in the order of 25 mm in thickness. Low-profile coolers with a thickness of about 15 mm are designed for small-sized cases, where saving space is extremely important. Fans of large thickness (30-40 mm) boast high cooling efficiency due to the increased impeller dimensions. However, they are noisier than standard models at the same speed and do not always fit into the case normally, sometimes touching other components.

Max. air flow

The maximum airflow that a cooling fan can create; measured in CFM — cubic feet per minute.

The higher the CFM number, the more efficient the fan. On the other hand, high performance requires either a large diameter (which affects the size and cost) or high speed (which increases the noise and vibration levels). Therefore, when choosing, it makes sense not to chase the maximum air flow, but to use special formulas that allow you to calculate the required number of CFM depending on the type and power of the cooled component and other parameters. Such formulas can be found in special sources. As for specific numbers, in the most modest systems, the performance does not exceed 30 CFM, and in the most powerful systems it can be up to 80 CFM and even more.

It is also worth considering that the actual value of the air flow at the highest speed is usually lower than the claimed maximum; see Static Pressure for details.

Static pressure

The maximum static air pressure generated by the fan during operation.

This parameter is measured as follows: if the fan is installed on a blind pipe, from which there is no air outlet, and turned on for blowing, then the pressure reached in the pipe will correspond to the static one. In fact, this parameter determines the overall efficiency of the fan: the higher the static pressure (ceteris paribus), the easier it is for the fan to “push” the required amount of air through a space with high resistance, for example, through narrow slots of a radiator or through a case full of components.

Also, this parameter is used for some specific calculations, however, these calculations are quite complex and, usually, are not necessary for an ordinary user — they are associated with nuances that are relevant mainly for computer enthusiasts. You can read more about this in special sources.

Min noise level

The lowest noise level produced by the cooling system during operation.

This parameter is indicated only for those models that have capacity control and can operate at reduced power. Accordingly, the minimum noise level is the noise level in the most “quiet” mode, the volume of work, which this model cannot be less than.

These data will be useful, first of all, to those who are trying to reduce the noise level as much as possible and, as they say, “fight for every decibel”. However, it is worth noting here that in many models the minimum values are about 15 dB, and in the quietest — only 10 – 11 dB. This volume is comparable to the rustling of leaves and is practically lost against the background of ambient noise even in a residential area at night, not to mention louder conditions, and the difference between 11 and 18 dB in this case is not significant for human perception. A comparison table for sound starting from 20 dB is given in the "Noise level" section below.

Noise level

The standard noise level generated by the cooling system during operation. Usually, this paragraph indicates the maximum noise during normal operation, without overloads and other "extreme".

Note that the noise level is indicated in decibels, and this is a non-linear value. So it is easiest to evaluate the actual loudness using comparative tables. Here is a table for values found in modern cooling systems:

20 dB — barely audible sound (quiet whisper of a person at a distance of about 1 m, sound background in an open field outside the city in calm weather);
25 dB — very quiet (normal whisper at a distance of 1 m);
30 dB — quiet (wall clock). It is this noise that, according to sanitary standards, is the maximum allowable for constant sound sources at night (from 23.00 to 07.00). This means that if the computer is planned to sit at night, it is desirable that the volume of the cooling system does not exceed this value.
35 dB — conversation in an undertone, sound background in a quiet library;
40 dB — conversation, relatively quiet, but already in full voice. The maximum permissible noise level for residential premises in the daytime, from 7.00 to 23.00, according to sanitary standards. However, even the noisiest cooling systems usually do not reach this indicator, the maximum for such equipment is about 38 – 39 dB.

Socket

Socket - processor connector - with which the corresponding cooling system is compatible.

Different sockets differ not only in compatibility with a particular CPU, but also in the configuration of the mounting place for the cooling system. So, when purchasing a processor cooling system separately, it is worth making sure that it is compatible with the socket. Nowadays, solutions are mainly produced for the following types of sockets: AMD AM2/AM3/FM1/FM2, AMD AM4, AMD AM5, AMD TR4/TRX4, Intel 775, Intel 1150, Intel 1155/1156, Intel 1366, Intel 2011/2011 v3, Intel 2066, Intel 1151/1151 v2, Intel 1200, Intel 1700.

Pump size

The dimensions of the pump that the water cooling system is equipped with.

Most often, this parameter is indicated for all three dimensions: length, width and thickness (height). These dimensions determine two points: the space required to install the pump, and the diameter of its working part. With the first, everything is quite obvious; we only note that in some systems the pump simultaneously plays the role of a water block and is installed directly on the cooled component of the system, and it is there that there should be enough space. The diameter approximately corresponds to the length and width of the pump (or the smaller of these dimensions if they are not the same — for example, 55 mm in the model 60x55x43 mm). Some operating features depend on this parameter. So, the large diameter of the pump allows you to achieve the required performance at a relatively low rotation speed; the latter, in turn, reduces the noise level and increases the overall reliability of the structure. On the other hand, a large pump costs more and takes up more space.

Pump power source

Type of power connector for the water pump.

3-pin. The three-pin power connector on older motherboards does not allow you to control the speed of the water pump motor in liquid cooling systems. At the same time, the pump always works in the maximum performance mode. Fresh "motherboards" are able to change the voltage on such connectors, thereby providing a change in engine speed.

4-pin. When using a 4pin power connector, it is supposed to control the speed of the pump motor using pulse-width modulation. A voltage of 12 V is applied to it with pulses. By changing the duration of the pulses, you can accurately set the speed of the water pump motor.

SATA. The SATA power connector will come in handy if all free 3pin and 4pin connectors are occupied on the motherboard.

Display

Remote or built -in information display in the design of the cooling system. The screen is used to display information about temperature, fan speed, voltage, etc. In advanced implementations, the display can be used to control cooling parameters to ensure optimal system performance and stability.
NZXT Kraken 360 often compared