Comparison Cooper&Hunter Unitherm Monotype CH-HP6.0MIRK 6 kW vs Cooper&Hunter CH-HP07UMPNK 7 kW

Add to comparison
Cooper&Hunter Unitherm Monotype CH-HP6.0MIRK 6 kW
Cooper&Hunter CH-HP07UMPNK 7 kW
Cooper&Hunter Unitherm Monotype CH-HP6.0MIRK 6 kWCooper&Hunter CH-HP07UMPNK 7 kW
Outdated ProductOutdated Product
TOP sellers
Main
The kit comes with a remote control with a touch screen, it is possible to connect to Modbus. When installing additional sensors, you can set the weather-dependent mode. On and off timers. Wi-Fi control. Refrigerant R32. Pipe diameter 1".
The heat pump has 5 operating modes: heating, cooling, DHW, heating + DHW, Cooling + DHW. An inverter driven scroll compressor with EVI technology is used. Pipe connection diameter 1".
Heat sourceair-waterair-water
Suitable forheating and DHWheating and DHW
In box
In box
outdoor unit (monoblock)
outdoor unit (monoblock)
Specs
Operating modeheating and coolingheating and cooling
Max. heat output6 kW7.4 kW
Max. cooling output5.8 kW5.9 kW
Power consumption (heating)1.2 kW1.8 kW
Power consumption (cooling)1.32 kW2.3 kW
Power source230 V230 V
Minimum operating temperature-30 °C-15 °C
Max. water temperature80 °C60 °C
Compressor
inverter
inverter
Energy efficiency
t°C outside77
Supply t°C40 °C35 °C
COP54.11
More specs
Control via smartphone+
RefrigerantR32R410A
Noise level58 dB56 dB
Country of brand originUSAUSA
Outdoor unit dimensions1150x758x345 mm1048x1605x445 mm
Outdoor unit weight96 kg70 kg
Added to E-Catalogmarch 2021january 2020

Max. heat output

The maximum heat output generated by a heat pump is the amount of heat it can transfer from the outdoors into the heating system and/or domestic hot water.

The heat output is the most important spec of a heat pump. It directly determines its efficiency and ability to provide the required amount of heat. Note that this spec is shown for optimal operating conditions. Such conditions are rare, so the actual output heat is usually noticeably lower than the maximum; this must be taken into account when choosing. There are special formulas for calculating the optimal value of the maximum heat output, depending on the specific condition.

Max. cooling output

Maximum cooling output delivered by the pump.

The pump operates in the cooling mode removing excess heat from the room to the environment — it plays the role of an air conditioner. The required cooling capacity depends on the area of the building, the specs of its thermal insulation and some other factors; methods of its calculation can be found in special sources. Also note here that conventional heating equipment (radiators, underfloor heating) is not suitable for cooling, for this it is necessary to use special equipment (for example, fan coil units).

Power consumption (heating)

Electric power consumed by the heat pump when operating only for heat transfer, without the use of an additional heating element (if any, see below). The ratio of thermal power to power input determines the thermal coefficient COP (see below) and, accordingly, the overall efficiency of the unit. It also affects overall power consumption (and therefore electricity bills), as well as some power and connection requirements — for example, models powered by 230 V and with a power of more than 5 kW cannot work from an outlet and require a special connection to the mains.

Power consumption (cooling)

For more information on power consumption, see the paragraph above. Here is indicated the consumption of electricity during operation in the cooling.

Minimum operating temperature

The lowest ambient temperature (air or ground, see Heat source) at which a heat pump can safely and reasonably efficiently perform its functions. Efficiency at minimum temperature, of course, is noticeably reduced, but the device can still be used as a heat source.

The data on the minimum operating T allows you to evaluate the suitability of the pump for the cold season.

Max. water temperature

The highest temperature to which the pump can heat the coolant. It is worth noting that such indicators can be achieved at a fairly high temperature of air or ground. And since heat pumps are used during the cold season, the actual maximum temperature, usually, is less than theoretically achievable. Nevertheless, this parameter makes it possible to evaluate the capabilities of the unit or its suitability for certain tasks.

Supply t°C

The temperature in the flow pipe for which the COP is specified. See below for more details on this coefficient. And this temperature is the temperature of the heat carrier at pump outlet, at which the given COP value is reached.

Note that manufacturers often go to the trick and measure COP for a relatively low temperature (much lower than the maximum temperature of the heat carrier — for example, 35 °C for a model with a maximum of 55 °C). This allows them to give quite impressive performance figures in the specifications. However, at higher temperatures, the actual energy cost per unit of thermal power will be greater and the actual COP will be lower.

COP

The COP (coefficient of performance) is a key characteristic that describes the overall efficiency of a heat pump. It represents the ratio between the thermal power and power consumption of the unit (see above) – in other words, how many kilowatts of thermal energy the pump produces per 1 kW of electricity consumed. In modern heat pumps, this figure can exceed 5.

However, note that the actual COP value may vary depending on the outside temperature and the supply temperature. The higher the difference between these temperatures, the more resources are needed to “pump” thermal energy and the lower the COP will be. Therefore, in the specifications it is customary to indicate the COP value for specific temperatures (and in many models – two values, for different options) – this allows you to evaluate the actual capabilities of the unit.

Control via smartphone

The ability to control the device using a smartphone/tablet is due to the presence of a built-in Wi-Fi module. By connecting the heat pump to the network and setting the necessary parameters in the application, you will have permanent access to the control of the pump. At the same time, some models do not have a built-in Wi-Fi module out of the box, but they can be installed additionally. In case basic functions won't be enough for you.
Cooper&Hunter CH-HP07UMPNK often compared