Comparison EcoStar DN15 1/2 L110 E-C 2.5 cold vs Gidrotek E-T 1.6-U cold

Add to comparison
EcoStar DN15 1/2 L110 E-C 2.5 cold
Gidrotek E-T 1.6-U cold
EcoStar DN15 1/2 L110 E-C 2.5 coldGidrotek E-T 1.6-U cold
Outdated Product
from $17.37
Outdated Product
TOP sellers
Main
Manufacturer's warranty — 4 years.
Manufacturer's warranty — 4 years.
Typehouseholdhousehold
Water temperaturefor cold waterfor cold water
Principle of operationmechanicalmechanical
Mechanical
vane-wheeled
single jet
vane-wheeled
single jet
Specs
Diameter (DN)15 mm15 mm
Max. pressure1 MPa1 MPa
Minimum water flow (Qmin)0.03 m³/h
Rated water flow (Qn)2.5 m³/h1.6 m³/h
Max. water temperature (Tmax)30 °C30 °C
Counter capacity99999 m³99999 m³
Division value0.0001 m³0.0001 m³
Mounting
Installationhorizontal / verticalhorizontal / vertical
Connection typethreadthread
Threaded connection size1/2 "1/2 "
Dimensions
110 mm /length/
110 mm /length/
General specs
Protection against external magnetic influence
Verification interval4 years4 years
Body materialbrassbrass
Country of originUkraineUkraine
Added to E-Catalogjuly 2021july 2021

Minimum water flow (Qmin)

Minimum water flow for this metre model.

The minimum flow rate is the smallest flow rate at which the counting mechanism can provide measurement with an acceptable error of ±5%. This deviation is higher than the counter error in the standard mode (from Qt to Qn, see below for details), it is considered undesirable, but generally acceptable. But when the flow rate drops below Qmin, the error increases to unacceptable values, and there is no question of acceptable measurement accuracy. So, ideally, it is worth choosing a metre in such a way that its Qmin is not higher than the water consumption at the minimum intensity of consumption. Detailed recommendations for estimating the actual water consumption for different water supply systems can be found in special sources.

Rated water flow (Qn)

Nominal flow rate for this metre model.

It is the highest flow rate at which the device can work indefinitely (during the entire service life) without failures, malfunctions and exceeding the maximum allowable error (± 2%). For a short time, a higher flow rate is also allowed (for more details, see “Maximum water flow (Qmax)”), however, the regular mode is still the mode in which this rate does not exceed Qn. So this parameter is the main one when choosing a device. Ideally, the actual water flow should always be in the range between the nominal and transitional (see above) flow.