United Kingdom
Catalog   /   Small Appliances   /   Health & Rehabilitation   /   Blood Glucose Monitors

Comparison Accu-Chek Performa vs Accu-Chek Performa Nano

Add to comparison
Accu-Chek Performa
Accu-Chek Performa Nano
Accu-Chek PerformaAccu-Chek Performa Nano
from £19.49 
Outdated Product
from $59.44 up to $62.00
Outdated Product
TOP sellers
Typeelectrochemicalelectrochemical
Measuring duration5 с5 с
Memory capacity500 measurements500 measurements
Measurements
Measurements
glucose
 
glucose
ketones
Additional modes
test
 
 
test
without eating
after eating
Averaging
in a week
in 14 days
in a month
per quarter
in a week
in 14 days
in a month
per quarter
Specs
Measurement range0.6 - 33.3 mmol/l0.6 - 33.3 mmol/l
Sample volume0.6 µl0.6 µl
Hematocrit10 - 65 %10 - 65 %
Encodingcodelesschip
Blood samplecapillarycapillary
Features
food note
date and time
 
synchronization with PC
 
alert
auto switch-off
food note
date and time
alarm clock
synchronization with PC
backlight
alert
auto switch-off
In box
Test strips10 pcs
Test strip modelAccu-Chek Performa
Lancets10 pcs
Lancet device
Cover/case
General
Calibrationplasmaplasma
Displaymonochromemonochrome
Power source1xCR20322xCR2032
Dimensions94х52х21 mm43x69х20 mm
Weight59 g40 g
Added to E-Catalogfebruary 2017february 2017

Measurements

Blood parameters that the blood glucose monitor can measure.

Glucose. Measuring blood glucose levels. It is this measurement that is colloquially called "measurement of sugar levels." There are other types of sugars in the blood, but it is the level of glucose that is the key physiological parameter. This function is the main one for glucometers and is supported by all models by definition.

Cholesterol. Measuring blood cholesterol levels is crucial because cholesterol and its derivatives play a significant role in metabolism. Elevated levels of "bad" (low molecular weight) cholesterol pose a risk of atherosclerotic disorders, including plaque deposition in vessels, reduced lumen, and an increased likelihood of heart attack or stroke. This measurement is especially important in the context of diabetes, as it often coincides with increased blood cholesterol levels.

Ketones. The capability to measure blood ketone levels is crucial, especially in conditions of insulin deficiency, as ketones can lead to deterioration of well-being when glucose levels are high. Even a slight increase in ketones can cause symptoms like irritability, nausea, vomiting, abdominal pain, and tachycardia. At critical levels, it can lead to ketoacidosis, a severe and life-threatening condition. Notably, ketone levels are not directly correlated...with blood sugar levels—they can be elevated with both high and low glucose. For diabetics, monitoring ketone levels is essential in certain situations. While the traditional method involves urine analysis using special test strips, modern blood glucose monitors can now measure ketone levels simultaneously with glucose levels, eliminating the need for separate measurements.

Additional modes

Test. To verify the functionality and accuracy of a blood glucose monitor, a control solution test is typically performed. This involves applying two control solutions with known glucose concentrations to the strips instead of blood. If the blood glucose monitor readings align with the expected values of the solutions, it indicates proper functionality. Periodic performance tests, ideally conducted weekly, are recommended, especially in cases of doubt about measurement results, such as discrepancies with one's health status.

No food intake. The mode of measuring blood counts on an empty stomach, before meals. It is used, in particular, to diagnose diabetes in the early stages, as well as to evaluate the effectiveness of drug-free (with the help of a diet) treatment of type 1 diabetes. Analysis data is stored in memory marked "on an empty stomach"; this allows you to track the trend over time.

— After eating. The mode of measuring blood parameters "on a full stomach", after eating. It is used, in particular, in insulin-dependent diabetes — to evaluate the effectiveness and correct the current dosage of insulin. The measurement results are stored in memory marked "after eating" in order to make it easier to track changes over a certain period of time.

Encoding

The encoding method provided in the device.

Encoding involves configuring the device for a specific set of test strips. This is necessary because test strips of the same type in different packages may contain different reagents. To ensure precise results, the device must be adjusted to a particular batch of strips, although there are exceptions — details below.

Codeless. Codeless blood glucose monitors are the most convenient and cost-effective option. However, they are less accurate because they don't account for the specific features of the test strips in their design, potentially introducing some error in measurement results. Despite this, the margin of error is often negligible, making them suitable for certain user categories, especially the elderly who may appreciate the simplicity of use without unnecessary settings.

Chip. Encoding using a replaceable chip. Such a chip is supplied with each package of test strips and is installed in the metre before using the package. Changing the chip is much easier and more convenient than entering the code manually (see "Code"), this option is quite popular in modern blood glucose monitors.

Automatic. Automatic encoding, requiring no additional user actions, involves applying a code to each test strip. The device reads this code during use, automatically adjus...ting to the specific characteristics of the strip. This option is both convenient and accurate, but the consumables for such devices can be relatively costly. — Code. Manual encoding requires users to enter the code from a new pack of test strips into the monitor before use. While cost-effective and fairly accurate, this method can be inconvenient for some users, especially the elderly. Given the availability of more advanced and user-friendly encoding technologies, devices with manual code entry are uncommon.

Features

Food note. The feature to annotate measurement results with information about the timing, specifically whether the analysis was conducted before or after a meal, is valuable. Devices with this capability can not only add notes to results but also gather separate statistics, such as averaging, for each result type. This method of data collection is considered optimal because glucose levels before and after a meal are distinct parameters with unique characteristics.

Date and time. The presence of a built-in clock and calendar in the blood glucose monitor. This function is intended mainly to record the time and date of each measurement — an indispensable function for collecting statistics. However, information about the time and date can be useful for purely domestic purposes.

Alarm clock. Classic alarm clock — a sound signal given by the device at a specified time. In glucometers, this function is intended not so much for getting up in the morning (although it can be used for this purpose), but to remind you that the time has come to take another measurement.

Voice notification. Blood glucose monitors with voice capabilities can audibly announce measurement results and may offer other functions through the built-in speaker. This feature is particularly beneficial for indivi...duals with visual impairments who face challenges in reading the display.

Synchronization with PC. The device's ability to sync with a computer, typically through USB connection, allows for the transfer of collected data since the last synchronization. A specialized application on the computer processes this data, offering more extensive functions than the device itself. These may include daily graph plotting, identifying minimum and maximum values, averaging for specific periods (refer to the relevant section), and facilitating data transfer to the attending physician.

Backlight. The presence of a backlight in the display of the device allows you to read readings from it in low light conditions — up to complete darkness. The backlight can turn on automatically or by pressing a special button.

Alert. An audible alert signals users when certain blood parameters reach critical levels, particularly designed for individuals facing health issues that impede reading the display (e.g., blurred vision). The alarm threshold is typically adjustable manually, tailored to individual cases and established in consultation with a doctor.

Auto swicth-off. Automatic shutdown function after a certain period of inactivity. Provides battery saving and eliminates the need for the user to manually turn off the device; some models do not provide manual shutdown at all — only automatic. The auto-off time, usually, is several minutes — in such a way that the user can familiarize himself with the measurement results without fuss.

Auto-ejecting test strip. Automatic ejection of the test strip: when the test is completed and the result is obtained, the device opens the holder, allowing the strip to fall out freely. In models without auto ejection, you usually need to press the appropriate button to remove the strip.

Test strips

The number of test strips included with the blood glucose monitor.

Test strips serve as the primary consumables for blood glucose monitors, typically provided in sets of around 10 to 20 pieces, occasionally up to 50. Since each analysis requires one strip, and diabetes monitoring involves 2 to 8 daily measurements, the supplied strips are mainly for initial device testing and performance evaluation. Additional consumables will need to be purchased for regular use.

Test strip model

The test strip models that the blood glucose monitor is compatible with. This information is especially important in light of the fact that consumables must be purchased separately for continuous use (complete test strips are usually only enough for familiarization and initial testing). For normal operation of the device and reliable results, use only consumables recommended by the manufacturer.

Lancets

The number of lancets supplied with the device.

Lancets, along with test strips, are essential supplies for a blood glucose monitor. These sterile disposable needles have a specialized design for skin piercing to obtain blood for analysis, with one needle per measurement. Kits typically include a matching quantity of lancets and test strips, usually ranging from around 20 to 50 pieces. It is expected that users will purchase additional needles as needed for consistent use.

Power source

The power source provided in the device.

CR2032. A slim "coin" battery, measuring 2 mm in thickness and 3.2 cm in diameter, is suitable for compact devices, including the smallest ones. While its capacity is less than that of AAA cells (refer to the relevant section), it remains sufficient for modern glucometers due to their low power consumption. Notably, some devices use two of these batteries to extend their overall battery life.

AAA. "Little" batteries, smaller than "AA" batteries but with a comparable design, are ideal for compact devices.

Battery. Operated by an internal, often non-removable battery, eliminating the need for regular battery purchases and replacements. However, in the event of a depleted battery, replacing it with a spare is a quick solution, while recharging requires time and a power source. Consequently, this option is not widely favored.

Mains. Operates by connecting to a 230 V household network, ensuring a constant power supply without concerns about battery depletion. However, glucometers, being primarily portable devices, are seldom equipped with mains power capabilities.
Accu-Chek Performa often compared
Accu-Chek Performa Nano often compared