Power sourceenergy independentenergy independent
Rated heat exchanger power12.2 kW20 kW
Performance (Δt ~25 °C)7 L/min10 L/min
Performance (Δt ~40 °C)4.3 L/min
Efficiency87 %85 %
Water supplywith pressurewith pressure
Heating elements11
Heating element type
heat exchanger
heat exchanger
Ignition typeturbinebatteries
Combustion chamber typeopen (atmospheric)open (atmospheric)
Flue diameter90 mm110 mm
Gas consumption1.4 m³/h2 m³/h
Features
Functions
thermostat
 
thermostat
display
Safety systems
overheat protection
frost protection
safety valve
gas control
overheat protection
 
 
gas control
General specs
Controlsmechanicalmechanical
Controls layoutfrontfront
Pipe connectionbottombottom
Dimensions (HxWxD)50.2x30.2x14.5 cm59х34х14 cm
Weight7.8 kg9 kg
Added to E-Catalogmarch 2015january 2013

Rated heat exchanger power

Rated power of the heat exchanger installed in the gas or indirect heater (see "Water heater type"), in other words, the amount of heat that can be transferred to the heated water through the heat exchanger.

This parameter is directly related to the performance of the water heater: high performance inevitably requires appropriate power. At the same time, the power of the heat exchanger is selected in such a way as to provide the necessary operating parameters (primarily performance and temperature). So when choosing a water heater, you should focus primarily on these parameters. Data on the power of the heat exchanger may be needed for some specific calculations — for example, assessing the compatibility of the heater with a boiler or solar collector: an external heat source must have no less thermal power than the heat exchanger, otherwise, it will be impossible to achieve the claimed performance.

It is also worth considering that the actual power of the heat exchanger depends on the temperature of the coolant flowing through it. In the characteristics of the water heater, usually, the power is given for the maximum allowable operating temperature; if the coolant is cooler, then the actual power will be lower.

Performance (Δt ~25 °C)

Water heater performance when heating water by approximately 25 °C above the initial temperature.

Performance is the maximum amount of hot water the unit can produce in a minute. It depends not only on the power of the heater as such, but also on how much water needs to be heated: the higher the temperature difference ΔT between cold and heated water, the more energy is required for heating and the smaller the volume of water with which the unit can handle in this mode. Therefore, the performance of water heaters must be indicated for specific options ΔT — namely 25 °C, 40 °C and/or 50 °C. And it is worth choosing according to this indicator taking into account the real needs for hot water: exactly how much and what temperature is needed for a particular situation. Methods of such calculations can be found in special sources.

Recall that water begins to be felt by a person as warm somewhere from 40 °C, as hot — somewhere from 50 °C, and the temperature of hot water in central water supply systems (according to official standards) is at least 60 °C. Thus, at Δt~25°C, for heating to at least the same 40°C, the initial water temperature must be at least 15°C (15+25=40°C). This is a rather high value — for example, in a centralized water supply system, cold water reaches 15 °C, except in summer, when the water pipes warm up noticeably; the same applies to water supplied from wells. So in the “Δt ~ 25 °C” mode, modern water heaters work quite rarely — eithe...r if the initial water temperature is high enough, or if it does not need to be heated much. Most often, the degree of heating is much higher, and the performance is lower. Nevertheless, data for a given degree of heating is still often given in the characteristics — including for advertising purposes, since with a low ΔT, the performance figures are quite impressive. In addition, this information can be useful in fact — for the situations mentioned above, when heating by 25 °C is quite enough.

Performance (Δt ~40 °C)

Water heater performance when heating water by approximately 40 °C above the initial temperature.

Productivity is the maximum amount of hot water the unit can produce in a minute. It depends not only on the power of the heater as such, but also on how much water needs to be heated: the higher the temperature difference ΔT between cold and heated water, the more energy is required for heating and the smaller the volume of water with which the unit can handle in this mode. Therefore, the performance of water heaters must be indicated for specific options ΔT — namely 25 °C, 40 °C and/or 50 °C. And it is worth choosing according to this indicator taking into account the real needs for hot water: exactly how much and what temperature is needed for a particular situation. Methods of such calculations can be found in special sources.

Recall that water begins to be felt by a person as warm somewhere from 40 °C, as hot — somewhere from 50 °C, and the temperature of hot water in central water supply systems (according to official standards) is at least 60 °C. Thus, ΔT ~ 40 °C is a rather significant degree of heating: at an initial temperature of about zero, it allows you to warm the water to the “warm” state, and at an initial temperature of 10 °C — to the “hot” state (10 + 40=50 °C). However, to achieve standard operating temperatures (60 °C or more), the heater most often has to work with a higher ΔT — and, accordingly, with a lower performance. However, the...performance data of the device in the “ΔT~40 °C” mode, although not perfect, quite accurately describes its real capabilities.

Efficiency

Heater efficiency.

Recall that efficiency is the ratio (in percent) between useful work and total energy consumed. In water heaters, this parameter is indicated mainly for gas models of an instant heat design. It describes what part of the heat from the gas burning in the combustion chamber is transferred to the water; accordingly, the higher the efficiency — the more efficient this model, the less gas it will need to heat a certain volume of water to a certain temperature. However, the increase in efficiency inevitably affects the price of the device; on the other hand, additional spending can quickly pay off due to gas savings.

In general, modern instant gas heaters have fairly high efficiency — from 81 – 84% in the most modest models to 90% or more in the most efficient ones.

Ignition type

The method of ignition of gas in gas water heaters.

— Batteries. Ignition from an electric spark created by a special electrical circuit powered by batteries. Battery ignition allows you to ignite without unnecessary wires, it can be used in models that do not require a mains connection at all. However, the user has to monitor the condition of the batteries and periodically change them, but this does not have to be done so often, and the replacement itself is not difficult.

— Mains. Ignition from an electric spark created by electricity from a socket. Batteries do not need to be changed in such systems but water heaters require a connection to the mains. Mains ignition is found mainly among gas heaters with advanced electronic control, in which power from the outlet is required for control circuits — it makes sense to power the ignition from the same outlet.

Piezo ignition. Ignition due to a piezoelectric element — a special device that generates electricity when a button is pressed (transforms the mechanical energy of pressing into electrical energy). Piezo ignition does not require battery power, and the life of the piezo element is usually comparable to the life of the heater itself.

Turbine. It is used in instant water heaters (see "Type"). With this type of ignition, electricity to crea...te a spark is generated by a microturbine driven by the movement of water through the heater. At the same time, in many cases, no additional actions are required from the user — ignition occurs automatically when the tap is opened and water begins to move through the device.

Note that most gas boilers also allow traditional ignition, from a match or other open flame. This option is provided as a spare, in case of failure of the main ignition system.

Flue diameter

Flue diameter for which the gas water heater is designed (see "Energy source").

This parameter is useful primarily for the selection and installation of a flue for a specific device. At the same time, it is worth remembering that the design of the duct differs depending on the type of combustion chamber (see above). So, for an open chamber, an ordinary pipe is used; in such cases, one diameter is indicated in the characteristics. But closed (turbocharged) combustion chambers are usually made under the so-called coaxial flue — a channel of the "pipe in pipe" type, where combustion products are brought out through the inner pipe, and the air necessary for fuel combustion is taken from the outside through the outer pipe. For such chimneys, two diameters are indicated for each of the pipes.

Gas consumption

It is the amount of gas a device consumes.

Functions

Among the functions of the water heater there are thermostat, water flow regulator, Smart (auto mode), programmer, display and control via the Internet. More about each of them

— Thermostat. A device that allows you to control the temperature of the water at the outlet of the heater. In storage models (see "Type"), the thermostat sets the maximum temperature for heating water in the tank; in instant devices, this function is carried out by changing the intensity of heating.

— Automatic water flow regulator. It is used in instant water heaters. Since the water in such devices heats up in the process of its movement through the heater, the higher the speed of water movement (the greater the pressure), the lower the heating temperature, and if the pressure is too high, the power of the device may simply not be enough for effective heating. The use of an automatic water flow regulator avoids this — this system regulates the speed of water movement through the heater, limiting it if necessary.

— Smart (auto mode). A special “smart” mode in which the boiler is controlled (primarily the intensity of heating) automatically. Specific features of this mode may vary depending on the model. However, the following format of operation is most common: during...the first week of use, the device remembers at what time of the day the hot water was used, and then the heater’s operating mode adjusts to this data. Thus, the water heater provides the user with hot water at the right time and, at the same time, does not waste energy on heating during hours when heating is not needed.

— Programmer. The presence of a programmable thermostat — a device that allows not only to maintain the temperature but also to programme the operation of the device for a certain period. The simplest programmers work like a timer, turning on at the right time (vacation or holiday mode, when the device is not active for several days, and when the family returns to the house, it will turn on and heat the water). More advanced ones allow you to set the mode of operation for individual days. Either way, this feature provides added convenience and eliminates the need to constantly adjust the operation of the device manually. On the other hand, the presence of a programmer affects the cost.

— Display. Usually, a simple LCD screen with a few characters is used as a display. However, even such equipment significantly increases the convenience and information content of management. Various service data can be shown on the display — from the temperature of the water in the tank to messages about malfunctions and failures. This feature slightly increases the cost of the device, but compared to the total cost of the heater, this moment is usually insignificant.

— Control via the Internet. The specific nuances of such control may vary: for example, some models use a special application installed on a smartphone or tablet, while others can work through a regular browser from any computer. However, this function allows you to control the heater from almost anywhere in the world — provided that there is access to the Internet. In addition, with this control, the user can also monitor the status of the device and receive various notifications (on and off, about the temperature of the water in the tank, about various problems, etc.).

Safety systems

The safety of water heaters can be carried out by such functions as overheat protection frost protection, dry heating protection, surge protection, electrical protection (RCD), anti-legionella, gas control and draft sensor. More about them:

— Overheat protection. Water heater safety system that automatically turns off the power supply or gas supply (depending on the type) when the heating element reaches a critical temperature. It avoids overheating and the troubles associated with it, ranging from heater failure to fire.

— Frost protection. Function to prevent freezing of water in the circuits, tank and/or heat exchanger of the water heater. It will be useful when the device is installed in a room with a low temperature and works with long breaks. Frozen water expands, which can damage the device; to avoid this, the frost protection monitors the temperature of the water in the device and turns on the heating when this temperature drops to a critical level.

— Dry heating protection. A safety system that prevents the heater from being switched on without the presence of water in it. Since the heating element does not transfer heat to the water when turned on, it heats up very q...uickly and, in a short time, reaches a high temperature that can lead to damage to the heater and even to a fire. The presence of protection against switching on without water allows you to avoid such unpleasant consequences.

— Voltage surge protection. System for protecting the heater from power surges. Electronically controlled models are usually equipped with such protection (see Control) since it is the control electronics that are most sensitive to problems with the power supply. Note that the capabilities of such systems are noticeably more modest than those of specialized stabilizers or protective systems: the “hardware” of a water heater can smooth out relatively weak power surges, but in case of serious failures, it will most likely simply turn off the device to avoid damage. However, this feature will be useful; except that in very unstable electrical grids, prone to frequent fluctuations, such a heater may require an external stabilizer.

— Electrical protection (RCD). Built directly into the heater, the RCD is a residual current device. Such a device is primarily intended to protect people from electric shock — for example, if the insulation is damaged and electricity leaks into the case or water. When a person comes into contact with this electricity, a so-called leakage current occurs. The RCD reacts to it and almost instantly turns off the power to the boiler, preventing electric shock.
Note that such safety devices are standardly installed directly in switchboards. However, the presence of an RCD in the water heater provides additional security. Naturally, such equipment is found mainly in electric models.

— Safety valve. A safety system that prevents a critical increase in water pressure in the heater. Usually, this protection is based on a safety valve that opens when a certain pressure level is reached and drains excess water, avoiding damage to the heater.

— Gas control. Gas heater safety system that automatically shuts off the gas supply in the event of a burner flame failure. It avoids filling the room with gas and possible unpleasant, and even tragic consequences. Resuming the gas supply after the protection is triggered must be done manually.

— Draft sensor. A sensor that monitors the presence of draft in the flue of a gas water heater. This function is especially important for models with open combustion chambers: in the absence of a draft, combustion products will fill the room where the heater is located. And this, in turn, can lead to a deterioration in people's well-being, health problems and even deaths. To avoid such consequences, this sensor, when detecting problems with the draft, turns off the gas supply and issues a warning about the problem. However, such equipment can also be found in models with closed combustion chambers. In them, the draft sensor performs mainly a diagnostic function, allowing you to determine what interferes with the normal operation of the burner.

— Anti-legionella. A function that prevents the growth of pathogenic bacteria in the tank and water heater circuits. Some types of such bacteria can live and multiply in fairly hot water — up to 60 °C. To avoid this, the anti-legionella system monitors the temperature of the water in the tank and periodically raises it to a level of about 65 °C. The specific methods of operation of such systems can be different: for example, some work strictly according to a set schedule (for example, once every two weeks), others turn on additional heating only if for some period (for example, a month) the water has not been heated to sufficiently high temperatures.