United Kingdom
Catalog   /   Tools & Gardening   /   Machines & Equipment   /   Welders

Comparison Sturm AW97I275 vs Tex-AC TA-00-003

Add to comparison
Sturm AW97I275
Tex-AC TA-00-003
Sturm AW97I275Tex-AC TA-00-003
Outdated Product
from $116.00
Outdated Product
TOP sellers
Main
There is no power switch, it is replaced by the Touch Start function, which turns on the device when the electrode touches the workpiece and turns it off if there is no activity for two minutes
Typeinverterinverter
Welding type
MMA
MMA
Specs
Welding currentDCDC
Input voltage230 V230 V
Power consumption8.5 kVA4.2 kVA
Open circuit voltage25.4 V70 V
Min. welding current20 А20 А
Max. welding current275 А300 А
Duty cycle80 %80 %
Max. electrode size5 mm5 mm
More features
Hot Start
Anti-Stick
digital display
Hot Start
Anti-Stick
digital display
General
Protection class (IP)21
Electrode holder cable3 m
Mass cable2 m
Dimensions (HxWxD)150x100x240 mm265x118x343 mm
Weight2.8 kg5.3 kg
Added to E-Catalogjune 2017june 2015

Power consumption

Power consumption of the welding machine, expressed in kilovolt-amperes.

kVA is a unit of power used in welding machines along with the more traditional kilowatts. The physical meaning of both units is the same — current multiplied by voltage; however, they denote different parameters. So, in kilowatts, only a part of the total power consumption is recorded — active power (goes to do work and to losses due to heating of individual parts); according to this indicator it is convenient to calculate the practical capabilities of the device. And kilovolt-amperes denote the total energy consumption — it also takes into account reactive power (it goes to losses in coils and capacitors during the operation of alternating current circuits). This data is useful for calculating the total load on the network or other power source.

The apparent power input in kVA will always be greater than the power in kW. However, some manufacturers go to the trick and indicate full power not at full, but at partial (for example, half) load. This gives the impression of efficiency, but is incorrect from a technical point of view. As for the ratio of energy consumption, the active power in kW is often 20-30% lower than the apparent power in kVA. So, in terms of kilovolt-amperes, it is quite possible to evaluate the performance of the unit.

As for specific values, in the most modest models they do not exceed 3 kVA. An indicator up to 5 kVA is considered low, up to 7 kVA — average, and in the most powerful units, the power consumption can reach 10 kVA or even more.

Open circuit voltage

The voltage supplied by the welding machine to the electrodes. As the name suggests, it is measured without load — i.e. when the electrodes are disconnected and no current flows between them. This is due to the fact that at a high current strength characteristic of electric welding, the actual voltage on the electrodes drops sharply, and this does not make it possible to adequately assess the characteristics of the welding machine.

Depending on the characteristics of the machine (see "Type") and the type of work (see "Type of welding"), different open circuit voltages are used. For example, for welding transformers, this parameter is about 45 – 55 V (although there are higher voltage models), for inverters it can reach 90 V, and for semi-automatic MIG / MAG welding, voltages above 40 V are usually not required. Also, the optimal values \u200b\u200bdepend on type of electrodes used. You can find more detailed information in special sources; here we note that the higher the open-circuit voltage, the easier it is usually to strike the arc and the more stable the discharge itself.

Also note that for devices with the VRD function (see "Advanced"), this parameter indicates the standard voltage, without reduction through VRD.

Max. welding current

The highest current that the welding machine is capable of delivering through the electrodes during operation. In general, the higher this indicator, the thicker the electrodes the device can use and the greater the thickness of the parts with which it can work. Of course, it does not always make sense to chase high currents — they are more likely to damage thin parts. However, if you have to deal with large-scale work and a large thickness of the materials to be welded, you simply cannot do without a device with the appropriate characteristics. Optimum welding currents depending on materials, type of work (see "Type of welding"), type of electrodes, etc. can be specified in special tables. As for specific values, in the most “weak” models, the maximum current does not even reach 100 A, in the most powerful ones it can exceed 225 A and even 250 A.

Protection class (IP)

The protection class to which the housing of the welding machine corresponds.

This parameter is traditionally denoted by the IP standard with two digits. It characterizes how well the case protects the hardware from foreign objects and dust (first digit), as well as from moisture (second digit). It is worth noting that in welding machines the degree of such protection is usually small — this is due to the fact that the case must be made ventilated. Here are the levels of protection against solid objects / dust that are relevant for modern models:

1 — protection against objects larger than 50 mm (comparable to the size of a human fist or elbow);
2 — from objects larger than 12.5 mm (we can talk about protection from fingers);
3 — from objects larger than 2.5 mm (the probability of accidental hit by most standard tools is excluded);


As for protection against moisture, it can be generally zero — that is, such a device can only be used in dry conditions. However, there are more advanced options:

1 — protection against drops of water falling vertically, with a strictly horizontal position of the device (the minimum degree of protection, in fact — from accidental ingress of a small amount of moisture);
2 — from vertical drops of water when the device deviates from the horizontal up to 15 ° (slightly higher than the minimum);
3 — from splashes falling at an angle of up to 60 ° to the vertical (we can talk about protect...ion from rain);
4 — from splashes falling from any direction (possibility of use in rain with strong winds);

Sometimes, instead of one of the numbers, the letter X is put — for example, IP2X. This means that the protection class for the corresponding type of exposure is not defined. In such a case, it is best to assume that there is no protection at all — this will provide maximum security and avoid unpleasant surprises.

Electrode holder cable

The length of the electrode holder cable supplied with the device.

As the name implies, this cable is used to connect the clamp for the welding electrode to the machine. The longer such a wire is, the more freedom the welder has in moving, the farther he can go without moving the machine itself. On the other hand, excessively long cables create problems in storage and transportation, and often during operation (you need to look for a place where to place the excess wire). Therefore, when choosing, you should proceed from what is more important for you: the ability to move away from the device or the overall compactness. As for specific numbers, most often the length of this wire varies from 2 to 3 m, but in some models it can reach 5 m.

Mass cable

The length of the ground cable supplied with the machine.

The mass cable is a wire that is connected to the workpiece with a clamp. In other words, this is the second contact required to close the circuit during electric welding; connecting such a wire actually turns the workpiece into one solid fixed electrode (paired with a movable welding electrode). As for the length of such a wire, the longer it is, the farther from the connection point you can place the machine and the more freedom of movement the welder gets. On the other hand, excessively long wires create problems in storage and transportation, and often during work (you need to look for a place where to place the excess cable). In addition, freedom of movement can be ensured by increasing the length of the second wire — for the electrode holder or burner. Thus, the mass cable in modern welding machines usually has a length of 1.2 to 3 m (with some exceptions — both smaller and larger). This length allows you to comfortably place the device and at the same time does not create problems.
Sturm AW97I275 often compared
Tex-AC TA-00-003 often compared