Comparison TermoBar KS-G-16DS 16 kW vs Atem Zhytomyr-3 KS-G-015 SN 16 kW

Add to comparison
TermoBar KS-G-16DS 16 kW
Atem Zhytomyr-3 KS-G-015 SN 16 kW
TermoBar KS-G-16DS 16 kWAtem Zhytomyr-3 KS-G-015 SN 16 kW
from $187.78 up to $226.00
Outdated Product
from $234.00 up to $287.44
Outdated Product
TOP sellers
Energy sourcegasgas
Installationfloorfloor
Typesingle-circuit (heating only)single-circuit (heating only)
Heating area128 m²120 m²
Technical specs
Heat output16 kW16 kW
Power supplyautonomous (no electricity)230 V
Coolant min. T40 °С
Coolant max. T90 °С90 °С
Heating circuit max. pressure2 bar1 bar
Consumer specs
Circulation pump
Boiler specs
Efficiency90 %92 %
Combustion chamberopen (atmospheric)open (atmospheric)
Inlet gas pressure13 mbar13 mbar
Max. gas consumption1.8 m³/h1.77 m³/h
Connections
Gas supply1/2"1/2"
Central heating flow1 1/2"1 1/2"
Central heating return1 1/2"1 1/2"
Safety
Safety systems
gas pressure drop
water overheating
flame loss
draft control
gas pressure drop
water overheating
flame loss
draft control
More specs
Dimensions (HxWxD)840x575x290 mm860x285x535 mm
Weight63 kg60 kg
Added to E-Catalogfebruary 2014february 2013

Heating area

The maximum area of the building that the boiler can effectively heat. However, it is worth considering that different buildings have different thermal insulation properties and modern buildings are much “warmer” than 30-year-old and even more so 50-year-old houses. Accordingly, this paragraph is more of a reference nature and does not allow a full assessment of the actual heated area. There is a formula by which you can derive the maximum heating area, knowing the useful power of the boiler and the climatic conditions in which it will be used; see Heat output for more details. In our case, the heating area is calculated according to the formula "boiler power multiplied by 8", which is approximately equivalent to use in houses that are more than a dozen years old.

Power supply

The type of electrical supply required for normal operation of the boiler. Power supply may be required not only for electric models but also for other types of boilers (see "Power supply") — in particular, for the operation of control automation. Connection options can be:

230 V. Work from a household system with a voltage of 230 V. At the same time, models with a power consumption of up to 3.5 kW can be connected to a standard outlet, but for high consumption devices, you need to connect directly to the distribution board. Many of the electric boilers with this connection also allow operation from 400 V (see below).

400 V. Operation from a three-phase system with a voltage of 400 V. This power supply is suitable for boilers with any power consumption. However, it is not as common as 230 V: in particular, it may be difficult to use it in a residential area. Therefore, this option is provided mainly in high-power devices for which a 230 V power supply is not suitable.

— Autonomous work. Work in completely autonomous mode, without an electricity connection. This format of operation is found in all boilers that do not use electrical heating (see "Energy source"), except for purely liquid fuel ones — in them, electricity is necessary for the operation of the fuel supply systems.

Coolant min. T

The minimum operating temperature of the heat medium in the boiler system when operating in heating mode.

Heating circuit max. pressure

The maximum pressure in the heating circuit of the boiler, at which it remains operational, and there is no risk of physical damage to the structure. For a heating system, the maximum pressure is usually about 3 bar, and for a domestic hot water circuit up to 10 bar. When the maximum pressure is exceeded, a safety valve is activated, and part of the water is discharged from the system until a normal pressure level is reached.

Efficiency

The efficiency of the boiler.

For electric models (see "Energy source"), this parameter is calculated as the ratio of net power to consumed; in such models, indicators of 98 – 99% are not uncommon. For other boilers, the efficiency is the ratio of the amount of heat directly transferred to the water to the total heat amount released during combustion. In such devices, the efficiency is lower than in electric ones; for them, a parameter of more than 90% is considered good. An exception is gas condensing boilers (see the relevant paragraph), where the efficiency can even be higher than 100%. There is no violation of the laws of physics here. It is a kind of advertising trick: when calculating the efficiency, an inaccurate method is used that does not take into account the energy spent on the formation of water vapour. Nevertheless, formally everything is correct: the boiler gives out more thermal energy to the water than is released during the combustion of fuel since condensation energy is added to the combustion energy.

Max. gas consumption

Maximum gas consumption in the boiler with the corresponding energy source (see above). Achieved when the gas heater is operating at full capacity; with reduced power and consumption, respectively, will be lower.

Note that boilers of the same power may differ in gas consumption due to the difference in efficiency. While the more fuel-efficient models tend to cost more, the price difference pays off in gas savings.