Comparison APC PMF83VT-RS vs Ippon BK-258

Add to comparison
APC PMF83VT-RS
Ippon BK-258
APC PMF83VT-RSIppon BK-258
from £57.49 
Expecting restock
Outdated Product
TOP sellers
Product typesurge protectorsurge protector
Specs
Cable length3 m5 m
Max. power2300 W2200 W
Max. load10 А10 А
Max. energy absorption2690 J107 J
Operation indicator
Power switchgeneralgeneral
Connection
Plug typeon camera flasheson camera flashes
Grounded sockets (type F)88
Phone jacks2
Coaxial connectors2
Protection
short circuit
overload
voltage surges (varistor)
automatic fuse
short circuit
overload
voltage surges (varistor)
automatic fuse
Design features
Safety socket cover
Wall mount
Outlets locationon both sides of the bodyin two rows
Socket plugsparallel to body (180°)angled
Size327x110x62 mm245x95x50 mm
Weight940 g
Color
Added to E-Catalogjuly 2015february 2015

Cable length

The length of the cable used to connect the surge protector to the network.

The longer the cable, the farther from the outlet you can install the device. On the other hand, a long cable can be inconvenient over short distances. Models on a coil are deprived of this drawback (see "Type"), this moment is compensated by the actual presence of the coil, but they differ in large dimensions and heavy weight. So when choosing, it is far from always worth chasing the maximum length of the wire.

Max. power

The highest power consumption of the connected devices that the surge protector can tolerate without consequences (to be more precise, with which it can work indefinitely without overloads, overheating, etc.).

This limitation is due to the fact that the higher the power at the same voltage, the higher the current passing through the equipment (in this case, through the surge protector); and off-design currents can lead to breakdowns and even accidents. And although in order to avoid these consequences, modern filters often provide various types of protection (see above), however, the operation of protection is still an emergency situation that is best avoided. Therefore, it is worth choosing a model according to this parameter in such a way that the maximum filter power is at least not lower than the total power consumption of the load. And it is best to have a margin of 20 – 30% — this will give additional guarantees in case of various deviations in the operation of the connected equipment.

Separately, it is worth highlighting the situations when the filter is planned to be used for the so-called reactive load — electrical appliances that widely use circuits on capacitors and/or inductors, for example, power tools or refrigeration units. The total power consumption of such devices (written in volt-amperes) can be much higher than the active power (which is indicated in watts). The recommended line filter power in such cases is calculated using special...formulas that can be found in the relevant sources.

Max. energy absorption

The maximum energy absorption provided by the mains filter, namely, the maximum pulse energy at which the device can safely absorb and dissipate it, completely protecting the connected load. The higher this indicator, the more reliable the filter, the more powerful power surges it can handle. In inexpensive models, the maximum absorption is calculated in tens of joules, in the most advanced models it can exceed 1000 J and even 2000 J.

Phone jacks

The number of telephone jacks provided in the design of the filter.

The presence of such connectors means that the filter can also be used to protect the communication line from various interference. Such protection is especially important when sending faxes and connecting to the Internet over a telephone line — these types of communications are quite susceptible to interference. The minimum number of telephone jacks, if any, is 2, input and output. Many filters with this function have 3 connectors — an input and 2 outputs (to the phone and to the computer); There are more, but extremely rare.

Coaxial connectors

The number of coaxial connectors provided in the extension cord. If this is a traditional antenna signal, then only 1 connector is provided at each end of the extension cord (mother or father). If we are talking about connecting multimedia devices using an RCA connection, then there can be 2 or 3 connectors on each side of the cable.

Safety socket cover

The presence of protective shutters from children in the design of the surge protector.

Such curtains are shutters that cover the current-carrying parts of the outlet and restrict access to foreign objects (most often, curious children try to put such objects into the outlet — hence the name). The design of the dampers is most often such that they open only under the pressure of the plug, when two contacts press on the curtains at the same time.

Outlets location

Options for placing sockets on the body of an extension cord or surge protector.

- Along the hull. Devices with the layout of sockets in one slender line, which is extended along the entire body of the extension cord or surge protector.

- In 2 rows. A popular scheme with the arrangement of sockets in 2 rows is on both sides of the upper plane of the device housing.

- In a circle. This category includes all extension cords and surge protectors with sockets in the form of a full circle or a semicircle.

- On both sides of the body. Sockets on several side faces of the case are found in compact cube models and in advanced surge protectors with relocated sockets on both sides of the case, which makes it easy to connect a large number of consumer devices.

Socket plugs

Placement of plugs in sockets of an extension cord or surge protector relative to the device case.

- at an angle. Seats with holes for plugs in such models are rotated at an angle of about 45 ° relative to the plane of the case. Such an option for placing plugs allows for convenient inclusion of plugs so that they do not interfere with each other and do not overlap adjacent slots.

Parallel to the body (180°). The holes for the plugs in this layout are arranged in sockets parallel to the body of the extension cord or surge protector. Large plugs are included in them perpendicularly, i.e. at an angle of 90° from the side of the "tail" with a network cable in relation to the axis of the device body.

Perpendicular to the body (90°). A fairly rare form factor that involves the placement of seats for a plug with a plug perpendicular to the axis of the device case. As a rule, openings at an angle of 90 ° relative to the housing are found in models for compact flat plugs and in surge protectors of atypical form factor. They can also coexist with sockets where the holes for the plugs are located at an angle.

- At an angle and parallel to the body. Combined variant of the layout of the holes for the plug, combining sockets with seating at an angle and parallel to the axis of the body of the extension cord or surge protector.

- At an...angle and perpendicular to the body. A variety of network filters and extension cords with different arrangements of holes in the mounting sockets. Most of them are placed at an angle with respect to the axis of the body, and one or more - perpendicular.