United Kingdom
Catalog   /   Camping & Fishing   /   Camping   /   Camping Stoves

Comparison Kovea KB-0408 vs Kovea TKB-8911-1

Add to comparison
Kovea KB-0408
Kovea TKB-8911-1
Kovea KB-0408Kovea TKB-8911-1
from $37.01 up to $40.41
Outdated Product
from $35.68 up to $51.05
Outdated Product
TOP sellers
Typecamping stovecamping stove
Fuelgasgas
Balloon mountthreadedthreaded
Specs
Power2030 W1500 W
Fuel consumption148 g/h110 g/h
Continuous operation time180 min240 min
Boiling time for 1 L of water258 с269 с
Power regulator
Piezo ignition
General
Burner diameter15 cm12 cm
Replaceable balloonsKGF-0220, KGF-0450, KGF-0230, KGF-0110KGF-0220, KGF-0450, KGF-0230, KGF-0110
Case included
Materialsteelsteel
Dimensions95x88x90 mm122x100x125 mm
Weight232 g290 g
Added to E-Catalogjuly 2013july 2013

Power

The rated power of the burner is the amount of heat generated by it during operation. For models with power control, the value is indicated at the maximum mode.

The nuances of choosing this parameter depend on the type of device. So, the general rule for burners and stoves (see "Type") states that at least 1 kW of power is needed to efficiently heat 1 liter of liquid. And the volumes that you have to deal with depend on the number of tourists and the expected conditions: in a warm climate, 600-700 mL per person is enough for 1 cooking, in a cool one — 1 liter, and it is better to clarify recommendations for different types of extreme tourism in special sources. Thus, the minimum indicator for burners is actually 1 kW, for stoves — 1.5 kW, and the most powerful ones can provide 3 kW or more. Note that more powerful burner models have the appropriate dimensions and weight, and you can heat a large amount of food several times; so for long hikes with luggage carried on you, a relatively low-powered device may be more suitable.

In the case of heaters, it can be assumed that a power of 1 – 1.5 kW is enough for 5 – 7 m2 of area — this is quite enough to heat a tent or tent, higher power is rarely required in fact. And for lamps, the main indicator of efficiency is not power, but luminous flux (see below).

Fuel consumption

The amount of fuel required for the normal operation of the burner for a certain time; usually stated in grams per hour. Different manufacturers may calculate fuel consumption differently, but most often it is indicated for normal operation, when the burner produces the power indicated in the documentation (see "Power"). Knowing the fuel consumption and the capacity of the cylinder used (see "Replaceable cylinders") or the built-in tank (see "Filling volume"), you can easily calculate the time of continuous operation of the burner.

Continuous operation time

The time that the burner is able to work without changing the cylinder or refilling the tank. Usually, the characteristics indicate the operating time at maximum power (see above); at lower power, the actual operating time may be longer than stated. However, it is best to evaluate and compare different models by directly claimed battery life.

Another important nuance is that battery life directly depends on the volume of the fuel tank — and many modern burners are designed for interchangeable cylinders produced in different volumes. Therefore, the characteristics may indicate for which cylinder model the continuous operation time is given (and for multi -fuel models, the type of fuel should also be specified). If there are no such data, the tank capacity required for a certain time can be calculated from fuel consumption: for example, gas consumption of 180 g / h and battery life of 120 min (2 h) mean that the data are given for a cylinder of at least 360 g (400 mL) gas. With other volumes, the time of continuous operation will differ accordingly.

Boiling time for 1 L of water

Approximate time required to boil 1 liter of cold water on the burner. Of course, in fact, the boiling time may differ from the claimed one, since it is affected by the shape and material of the dishes, ambient temperature, etc.; however, this parameter quite clearly characterizes the overall efficiency of the device, it is quite possible to compare different models with each other. At the same time, it should be taken into account that when working with other volumes, the time may not change in direct proportion: for example, if 1 liter requires 300 s, then 2 liters may require not 600 s, but more, but 0.5 L — not 150 s, but less.

Burner diameter

The diameter of the burner provided in the burner or stove (see "Type"). Indicated by the size of the flame corolla in normal operation. First of all, compatibility with dishes depends on this size: the size of the dishes must be at least the diameter of the burner, otherwise effective use will be impossible. In addition, this indicator affects the overall dimensions of the burner; and a larger burner usually means more power (see above), although there is no hard dependency here.

Weight

The total weight of the device. Usually, the specifications indicate "dry" weight — excluding fuel.

Lightness is important on long hikes where you have to carry your gear; on the other hand, ceteris paribus, less weight means either low strength and reliability, or greater cost. The lightest classic type burners and lamps (see "Type") weigh up to 200 g, in the working position, most of the mass of such a device falls on fuel. However, there are also more massive models. For plates, in turn, lightness is not critical, and most of these models are quite heavy — 1 kg or more. In heaters, the weight can be different — from 60 – 70 g in pocket hand warmers to 1.5 kg (or even more) in powerful outdoor appliances.
Kovea KB-0408 often compared