United Kingdom
Catalog   /   Climate, Heating, Water Heating   /   Water Supply & Pumps   /   Surface Pumps

Comparison Pedrollo JSWm 10MX vs Pedrollo JSW 3BM

Add to comparison
Pedrollo JSWm 10MX
Pedrollo JSW 3BM
Pedrollo JSWm 10MXPedrollo JSW 3BM
from $105.00 up to $126.50
Outdated Product
from $274.25 up to $329.59
Outdated Product
TOP sellers
Suitable forclean waterclean water
Specs
Maximum performance
4800 L/h /maximum/
7200 L/h /maximum/
Maximum head
46 m /maximum/
60 m /maximum/
Max. pressure6.5 bar
Pump typecentrifugalcentrifugal
Suction typeself-primingself-priming
Suction height9 m8 m
Mechanical impurities50 g/m³
Maximum liquid temperature40 °С40 °С
Suction systemsingle-stagesingle-stage
Outlet size1"1"
Inlet hole size1"1 1/4"
Engine
Maximum power750 W1500 W
Power sourceelectricelectric
Mains voltage230 V400 V
General specs
Protection class (IP)X444
Country of originItalyItaly
Pump housing materialcast ironcast iron
Impeller / auger materialplasticbrass
Dimensions402x201x180 mm530x206x165 mm
Weight13.7 kg25.1 kg
Added to E-Catalogapril 2015january 2015

Maximum performance

The maximum volume of water that the device can pump in a certain amount of time. It is one of the key specs of any pump because characterizes the volume of water with which the device can work. At the same time, it does not always make sense to pursue maximum performance — after all, it significantly affects the dimensions and weight of the unit.

Some formulas allow you to derive optimal performance values for different situations. So, if the pump is designed to supply water to water intake points, its minimum required performance should not be lower than the highest total flow rate; if desired, a margin of 20-30% can be added to this value. And for sewer models (see "Suitable for"), everything will depend on the volume of wastewater. More detailed recommendations for choosing a pump depending on performance can be found in special sources.

Maximum head

The maximum head generated by the pump. This parameter is most often indicated in meters, by the height of the water column that the unit can create — in other words, by the height to which it can supply water. You can estimate the pressure created by the pump using a simple formula: every 10 m of head corresponds to a pressure of 1 bar.

It is worth choosing a pump according to this parameter, taking into account the height to which it should supply water, as well as adjusting for losses and the need for pressure in the water supply. To do this, it is necessary to determine the difference in height between the water level and the highest point of water intake, add another 10 to 30 m to this figure (depending on the pressure that needs to be obtained in the water supply), and multiply the result by 1.1 — this will be the minimum pressure required.

Max. pressure

The highest pressure that the pump is capable of creating during operation. This parameter is directly related to the maximum head (see above); however, it is less obvious, and therefore, it is indicated rarely.

Suction height

The largest difference between the height of the pump and the height of the water level at which the pump can provide normal suction. Without special devices, the maximum value of this parameter is 7-8 m — this is due to the physics of the process. However, when using an ejector (see below), the suction height can be increased several times.

Mechanical impurities

The maximum amount of mechanical impurities in the suction water at which the pump can operate normally (of course, if the particles of these impurities do not exceed the maximum size possible for this model; see above for details). Pure water is considered to be water with an impurity content of up to 20 g per cubic meter, but in sewage, the bill can already go to tens of kilograms per cubic meter.

Inlet hole size

The size of the thread designed to connect the pump to the suction line. This parameter is completely similar to the size of the outlet (see above) — in particular, it can be specified both for the nozzle and for the inlet of the pump.

Maximum power

Rated power of the pump motor. The more powerful the engine, the higher the performance of the unit, usually, the greater the pressure, suction height, etc. Of course, these parameters largely depend on other features (primarily the pump type, see above); but models similar in design can be compared in terms of power.

Note that high power, usually, increases the size, weight and cost of the pump, and also implies high costs of electricity or fuel (see "Power source"). Therefore, it is worth choosing a pump according to this parameter taking into account the specific situation; more detailed recommendations can be found in special sources.

Mains voltage

The supply voltage for which the pump with an electric motor is designed is electric or battery (see "Power source").

— 230 V. Voltage of ordinary household mains. Most pumps with this power supply can work directly from the socket, only the most powerful models (3 kW and above) require a special connection format (directly to the switchboard). However, 230 V mains are relatively poorly suited for high-power units. Therefore, this type of power supply is found mainly among electric pumps of low and medium power, designed mainly for domestic use.

— 400 V. Power supply from three-phase 400 V mains is suitable for electric pumps of any power — including heavy industrial equipment. However, this type of power supply is also found among relatively "weak" models — including 400 W and below. This is because a three-phase connection has several general advantages over a single-phase one: in particular, such mains are better able to withstand high loads (including power surges during motor starts), they are better suited for long-term continuous operation, and also allow more accurate accounting of consumed energy. If there is access to a 400 V mains at the pump installation site, it is most likely that such a power supply will be optimal.

— 12 V. A value that is practically not found among mains pumps, but quite popular in battery models (see "Power source"). In this case, voltage does not affect performance, but it may be useful when looking for a...replacement/replacement battery or third-party charger. At the same time, we emphasize that the use of 12-volt car batteries with pumps is highly discouraged: such energy sources are designed for a specific format of operation, and their abnormal use is fraught with accidents.

— 18 V. Another version of the operating voltage found in battery pumps; has no fundamental differences from the 12 V described above.

Protection class (IP)

An indicator that determines the degree of protection of dangerous (moving and current-carrying) parts of the hardware of the pump from adverse effects, namely solid objects and water. Since pumps, by definition, are used for pumping liquids, and many of them can normally pass quite large particles, in this case, we are talking about protection against moisture and foreign objects from outside.

The level of protection is usually indicated by a marking of the letters IP and two numbers, the first of which indicates protection against the effects of solid objects, and the second — against the ingress of water.

For the first digit, each value corresponds to the following protection values: 1 — protection against objects with a diameter of more than 50 mm (large body surfaces) 2 — against objects with a diameter of more than 12.5 mm (fingers, etc.) 3 — against objects more than 2.5 mm (most tools) 4 — against objects larger than 1 mm (virtually all tools, most wires) 5 — dust-proof (total protection against contact; dust can enter, but does not affect the operation of the device) 6 — dust-proof (case with full dust protection and contact).

For the second digit: 1 — protection against vertically falling drops of water 2 — against drops of water with a deviation of up to 15° from the vertical axis of the device 3 — against drops of water with a deviation of up to 60° from the vertical axis of the device (rain) 4 — against splashes from any direct...ion 5 — from jets from any direction 6 — from sea waves or strong water jets 7 — short-term immersion to a depth of up to 1 m (without the possibility of continuous operation in immersed mode) 8 — long-term immersion to a depth of more than 1 m (with the possibility of permanent operation) in immersed mode).

Note that in some cases one of the numbers can be replaced by the letter X — this means that official certification for the corresponding parameter has not been carried out. In pumps, X is usually put in place of the first digit, because. a high degree of moisture resistance (and for submersible models, for example, it must, by definition, correspond to 8) means a high degree of protection against solid contaminants.
Pedrollo JSWm 10MX often compared