Comparison Mitsubishi Electric LGH-15RVX vs Mitsubishi Electric LGH-15RX5

Add to comparison
Mitsubishi Electric LGH-15RVX
Mitsubishi Electric LGH-15RX5
Mitsubishi Electric LGH-15RVXMitsubishi Electric LGH-15RX5
from $1,448.00 up to $1,457.32
Outdated Product
from $840.00 up to $847.46
Outdated Product
TOP sellers
System typecentralizedcentralized
Ventilation typerecuperatorrecuperator
Mountingsuspended
suspended /or on wall/
Mounting diameter100 mm100 mm
Specs
Air filtersG3G3
Minimum air flow (recuperation)38 m³/h110 m³/h
Maximum air flow (recuperation)150 m³/h150 m³/h
Number of fan speeds44
Maximum noise level28 dB28 dB
External static pressure95 Pa140 Pa
Type of heat exchangerplateplate
Heat exchanger efficiency84 %85.5 %
Minimum operating temperature-10 °C-15 °C
General specs
Remote control
 /with timer/
Power consumption in ventilation mode49 W110 W
Mains voltage230 V230 V
Country of originJapanJapan
Dimensions610x273x780 mm735x273x780 mm
Weight20 kg20 kg
Added to E-Catalogjuly 2016july 2016

External static pressure

Static pressure created by the air handling unit at the inlet.

This parameter is required for calculations related to the selection of the installation for a ventilation system with long air ducts. The static pressure must be equal to the resistance of the duct network at a given air flow. More detailed information about this parameter and its application can be found in special sources.

Heat exchanger efficiency

Efficiency of the heat exchanger used in the heat exchanger of the supply and exhaust system (see "Features").

Efficiency is defined as the ratio of useful work to the energy expended. In this case, this parameter indicates how much heat taken from the exhaust air, the heat exchanger transfers to the supply air. The efficiency is calculated by the ratio between the temperature differences: you need to determine the difference between the outdoor air and the supply air after the heat exchanger, the difference between the outdoor and exhaust air, and divide the first number by the second. For example, if at an outside temperature of 0 °С, the temperature in the room is 25 °С, and the heat exchanger produces air with a temperature of 20 °С, then the efficiency of the heat exchanger will be (25 – 0)/(20 – 0)= 25/20 = 80%. Accordingly, knowing the efficiency, it is possible to estimate the temperature at the outlet of the heat exchanger: the temperature difference between the inside and outside must be multiplied by the efficiency and then the resulting number is added to the outside temperature. For example, for the same 80% at an outdoor temperature of -10 °C and an internal temperature of 20 °C, the inflow temperature after the heat exchanger will be (20 – -10)*0.8 + -10 = 30*0.8– 10 = 24 – 10 = 14 °C.

The higher the efficiency, the more heat will be returned to the room and the more savings on heating will be. At the same time, a highly efficient heat e...xchanger is usually expensive. Also note that the efficiency may vary slightly for certain values of the external and internal temperatures, while manufacturers tend to indicate the maximum value of this parameter — accordingly, in fact, it may turn out to be lower than the claimed one.

Minimum operating temperature

The lowest outdoor air temperature at which the ventilation unit can be safely used; more precisely, the minimum inlet air temperature at which the unit can operate normally, without malfunctions, for an indefinitely long time.

It is worth choosing according to this parameter taking into account the climate in which it is planned to use the unit: the device should normally tolerate at least the average winter temperature, and it is best to have some reserve in case of a harsh winter. However, many modern models allow operation at -10 °C and below, and in the most cold-resistant ones, the temperature minimum can reach -35 °C. So choosing a unit for a temperate climate is usually not a problem. Also note that if an installation that is ideally suited for all other parameters cannot cope with low temperatures, the situation can be corrected by using an additional heater at the inlet of the ventilation system.

Note that if the minimum temperature is not indicated in the characteristics, it is best to proceed from the fact that this model requires a temperature not lower than 0 °C. In other words, in cold weather, it is worth using only the equipment for which this possibility is directly stated.

Power consumption in ventilation mode

Electrical power consumed by the air handling unit in normal operation (for models with capacity control - at maximum speed). Knowing this power, you can determine the requirements for connecting the unit, as well as estimate how expensive its operation will be in light of electricity bills. It should be taken into account that for models with an electric reheater (see “Type of reheater”), in this case we are talking about the power of only the ventilation system, and the power of the reheater is given separately (see above); thus, the total power consumption when operating in full format will correspond to the sum of these powers.

Also, based on the power consumption, you can to a certain extent evaluate the performance of the installation: “gluttonous” units usually provide an appropriate flow.