Daikin VKM50GBM
Daikin VKM80GB
Daikin VKM50GBMDaikin VKM80GB
Outdated ProductOutdated Product
TOP sellers
Main
CO2 sensor — turns off the unit when the air quality is normal
CO2 sensor — turns off the unit when the air quality is normal
System typecentralizedcentralized
Ventilation typerecuperatorrecuperator
Mountingsuspendedsuspended
Specs
Features
cooler /freon (R410A)/
humidifier /2.7 L/hour/
cooler /freon (R410A)/
 
CO₂ carbon dioxide sensor
Minimum air flow (recuperation)440 m³/h640 m³/h
Maximum air flow (recuperation)500 m³/h750 m³/h
Maximum noise level38 dB42 dB
External static pressure210 Pa210 Pa
Type of heat exchangerplateplate
Heat exchanger efficiency76 %78 %
General specs
Remote control
EC fan
Mains voltage230 V230 V
Country of originJapanJapan
Dimensions1764x387x832 mm1764x387x1214 mm
Weight100 kg110 kg
Added to E-Catalogaugust 2017august 2017

Features

Additional functions provided in the design of the unit in addition to ventilation.

Recuperator. A heat exchanger that prevents "blowing" heat from the room during the cold season. The principle of operation of the heat exchanger is that it takes energy from the blown air and transfers it to the incoming one — thus, ventilation sends relatively cool air out and supplies preheated air into the room. The use of a heat exchanger can significantly reduce heat loss and, accordingly, heating costs — the amount of heat returned in the most advanced heat exchangers can reach 97% (see "Heat exchanger efficiency"). At the same time, such systems are often passive and do not themselves consume energy (and where it is required, the consumption is still lower than the amount of saved heat). Naturally, this function is found only in full-size, supply and exhaust units (see "Type of ventilation"). Note that external recuperators are also produced, which can be supplemented with ventilation units that do not have this function; however, an integrated heat exchanger is often more convenient and efficient.

Heater. The built-in heater intended for heating the air coming into the room. At the same time, in contrast to the heat exchanger described above, energy is used...for heating from a third-party source — an electric heater or a water heat exchanger (see "Heater type"). This method of heating requires additional energy costs, and water circuits are also quite troublesome to connect. But it is much more efficient: if the air supplied from the heat exchanger into the room cannot be warmer than the air blown out, then this is not a problem for the heater. This function is mainly used to raise the temperature of the supply air supplied from the heat exchanger (built-in or separate) to the temperature of the extract air and thus avoid unnecessary heat losses.

Cooler. A built-in system that reduces the temperature of the air supplied to the room. Simplified, this function can be called a "built-in air conditioner" — because air conditioners are usually used to cool the air in hot weather. In fact, in some cases, installing an air ventilation unit with a cooler can eliminate the need for separate air conditioners. On the other hand, such systems are quite complex and expensive, and therefore they are used rarely, mainly among centralized units(see "System").

Humidifier. A system that increases the humidity of the air supplied to the room. The peculiarity of the human body is such that the feeling of a comfortable climate depends not on the absolute, but on the relative humidity of the surrounding air. Relative humidity, on the other hand, depends not only on the actual amount of water vapour in the air but also on temperature: physical laws are such that as the temperature rises, relative humidity drops, even though the amount of moisture in the air remains unchanged. In fact, this leads to the fact that during the cold season, the heated outside air begins to seem dry. To avoid this effect in climate technology, including air ventilation units, humidification systems may be provided. Note that such systems usually require either a connection to the water supply system or regular refilling of the water tank.

Ionizer. A system that saturates the air entering the room with negatively charged ions. The effect of such ions on the climate is positive — the air feels fresher, ionization contributes to the sedimentation of contaminants on the floor and walls and provides a bactericidal effect. In addition, it is believed that ionized air is good for health, improves immunity and recovers from injuries and illnesses.

Maximum noise level

The noise level produced by the air ventilation unit in normal operation.

This parameter is indicated in decibels, while the decibel is a non-linear unit: for example, a 10 dB increase gives a 100 times increase in sound pressure level. Therefore, it is best to evaluate the actual noise level using special tables.

The quietest modern ventilation units produce about 27–30 dB — this is comparable to the ticking of a wall clock and allows you to use such equipment without restrictions even in residential premises (this noise does not exceed the relevant sanitary standards). 40dB is the daytime noise limit for residential areas, comparable to average speech volume. 55–60 dB — the norm for offices, corresponds to the level of loud speech or sound background on a secondary city street without heavy traffic. And in the loudest, they give out 75–80 dB, which is comparable to a loud scream or the noise of a truck engine. There are also more detailed comparison tables.

When choosing according to the noise level, it should be taken into account that the noise from the air movement through the ducts can be added to the noise of the ventilation unit itself. This is especially true for centralized systems (see "System"), where the length of the ducts can be significant.

Heat exchanger efficiency

Efficiency of the heat exchanger used in the heat exchanger of the supply and exhaust system (see "Features").

Efficiency is defined as the ratio of useful work to the energy expended. In this case, this parameter indicates how much heat taken from the exhaust air, the heat exchanger transfers to the supply air. The efficiency is calculated by the ratio between the temperature differences: you need to determine the difference between the outdoor air and the supply air after the heat exchanger, the difference between the outdoor and exhaust air, and divide the first number by the second. For example, if at an outside temperature of 0 °С, the temperature in the room is 25 °С, and the heat exchanger produces air with a temperature of 20 °С, then the efficiency of the heat exchanger will be (25 – 0)/(20 – 0)= 25/20 = 80%. Accordingly, knowing the efficiency, it is possible to estimate the temperature at the outlet of the heat exchanger: the temperature difference between the inside and outside must be multiplied by the efficiency and then the resulting number is added to the outside temperature. For example, for the same 80% at an outdoor temperature of -10 °C and an internal temperature of 20 °C, the inflow temperature after the heat exchanger will be (20 – -10)*0.8 + -10 = 30*0.8– 10 = 24 – 10 = 14 °C.

The higher the efficiency, the more heat will be returned to the room and the more savings on heating will be. At the same time, a highly efficient heat e...xchanger is usually expensive. Also note that the efficiency may vary slightly for certain values of the external and internal temperatures, while manufacturers tend to indicate the maximum value of this parameter — accordingly, in fact, it may turn out to be lower than the claimed one.