Comparison VENTS TwinFresh R-50-2 vs VENTS TwinFresh RA-50

Add to comparison
VENTS TwinFresh R-50-2
VENTS TwinFresh RA-50
VENTS TwinFresh R-50-2VENTS TwinFresh RA-50
from $199.00
Outdated Product
from $231.28
Outdated Product
TOP sellers
System typedecentralizeddecentralized
Ventilation typerecuperatorrecuperator
Mountingwallwall
Mounting diameter150 mm150 mm
Specs
Air filtersG3G3
Minimum air flow (recuperation)25 m³/h25 m³/h
Maximum air flow (recuperation)50 m³/h50 m³/h
Number of fan speeds22
Minimum noise level24 dB
Maximum noise level34 dB34 dB
Type of heat exchangerenthalpyenthalpy
Heat exchanger materialceramicsceramics
Heat exchanger efficiency90 %90 %
Minimum operating temperature-20 °C-20 °C
General specs
Remote control
Power consumption in ventilation mode5 W5 W
Mains voltage230 V230 V
Minimum wall thickness120 mm250 mm
Maximum wall thickness470 mm470 mm
Country of originUkraineUkraine
Added to E-Catalogaugust 2016august 2016

Remote control

The presence of a remote control in the delivery set of the air ventilation unit.

This configuration is provided in most decentralized models (see "System"). However, it is often found in centralized ones. The possibility of a remote control provides additional convenience for the user — you do not need to approach the unit every time. In addition, many control functions can be transferred to the remote control, making the installation itself more compact (this is true for the mentioned decentralized equipment, which has a rather small size).

Note that the remote control can be both portable and wall-mounted, designed to be permanently in one place (like a wall light switch).

Minimum wall thickness

The minimum wall thickness on which the air ventilation unit can be hung with the possibility of wall mounting.

This parameter is indicated for models mounted directly into a hole in the wall — see "Mounting" for details. The installation length (the length of the pipe between the trims) can usually be adjusted to suit specific wall thicknesses. However, if this thickness is too small, then even an extremely shortened pipe will stick out of it, preventing the entire structure from being securely fixed. This is the reason for this limitation. Theoretically, the situation can be corrected — for example, by building up a wall at the installation site — however, in fact, such options are unlikely to be considered seriously. Nevertheless, in most models, this limitation does not exceed 300 mm, and it is very rarely necessary to install ventilation units on thinner walls.