Comparison Ballu BHP-PE-3 vs Ballu BHP-PE-2

Add to comparison
Ballu BHP-PE-3
Ballu BHP-PE-2
Ballu BHP-PE-3Ballu BHP-PE-2
from $57.24 up to $66.80
Outdated Product
from $47.20 up to $56.68
Outdated Product
TOP sellers
Power supplyelectricelectric
Max. thermal output
3 kW /1.5 kW/
2 kW /1 kW/
Max. heating area30 m²20 m²
Increase in air temperature (ΔT)39 °C25 °C
Specs
Supply voltage230 V230 V
Rated current13.6 A9.1 A
Power consumption30 W30 W
Heating elementtubular heatertubular heater
Airflow230 m³/h230 m³/h
Power adjustment
stepped
stepped
Features
thermostat
fan mode
thermostat
fan mode
Safety features
overheat protection
overheat protection
More cpecs
Tilt adjustment
Protection class (IP)2020
Dimensions (WxHxD)245x315x250 mm245x315x250 mm
Weight3.7 kg3.4 kg
Added to E-Catalogoctober 2015october 2015

Max. thermal output

The highest heating power produced by an industrial heater.

The maximum area that the unit can effectively heat directly depends on this parameter (see below). Even if it is not indicated in the specs, it can be approximately determined from the calculation that for heating 1 m² of a room with a standard ceiling height of 2.5 m and good thermal insulation will require 100 W of thermal power. If the ceiling height is significantly different, then the power required for heating can already be withdrawn from the volume of the room — every 2.5 cubic metres of volume will require the same 100 W (and the volume is found by multiplying the area by the height of the ceiling). There are also more complex formulas for the most accurate calculation, taking into account the degree of thermal insulation, the temperature difference between inside and outside the room, etc.; they can be found in special sources.

Note that in electric models (see "Power supply"), the maximum thermal power, in addition to all of the above, also determines the total power consumption of the unit: the power consumption (see below) cannot be less than the thermal output (usually, it is somewhat higher due to for the removal of part of the energy for the operation of the fan). In devices with a water circuit, the actual thermal output depends on the temperature of the coolant at the inlet and outlet. Therefore, in the characteristics, a certain standard value is usually indicated, and in t...he notes, it is specified for which temperatures it is relevant (for example, 90 ° / 70 °).

Max. heating area

The largest area of the room that the industrial heater can effectively heat.

When determining the maximum area, usually, a universal formula is used that is valid for all heaters: 1 m² of floor space in a room with a standard ceiling height of 2.5 m requires 100 W of thermal power. Therefore, if the ceiling height differs markedly from this value, the actual heating area should be recalculated; for more details on scaling, see “Maximum thermal output".

Increase in air temperature (ΔT)

This parameter describes the difference between the air temperature at the inlet to the heater and the outlet temperature — in other words, by how many degrees the air temperature rises when passing through the unit. The higher ΔT, the hotter the outgoing air will be and the more attentively it is necessary to observe safety measures (do not place the device near flammable and heat-sensitive materials, prevent people from being in the immediate vicinity of the gun exit, etc.).

Rated current

The current consumed by the heat gun during normal operation. This parameter is useful primarily for assessing the load on the mains that occurs during the operation of the unit and organizing the appropriate connection. In particular, the rated current of the fuse installed in the connection circuit cannot be lower than the total rated current of the connected load — otherwise, the power will be turned off. Heat guns (primarily electric, see "Power supply") are quite high consumption consumers in terms of current.