Comparison Paramed Puppy vs Gamma Effect Max
Add to comparison | ![]() | ![]() |
|---|---|---|
| Paramed Puppy | Gamma Effect Max | |
| Outdated Product | from $24.80 up to $36.76 | |
| User reviews | ||
| TOP sellers | ||
Designed for both children and adults. Two types of masks are included respectively. | ||
| Type | compressor | compressor |
| Purpose | stationary | stationary |
| Design for kids | ||
Specs | ||
| Medicine container | 6 ml | 8 ml |
| Max air flow | 7.5 L/min | |
| Nebulization rate | 0.25 ml/min | |
| Particle size | 0.5 – 5 µm | |
| Medium particle size (MMAD) | 3 µm | |
| Nozzles | adult mask children's mask nozzle for mouth | adult mask children's mask nozzle for mouth |
General | ||
| Power source | mains | mains |
| Dimensions | 230x220x140 mm | 198x150x109 mm |
| Weight | 1700 g | 160 g |
| Added to E-Catalog | august 2017 | august 2014 |
Compare Paramed Puppy and Gamma Effect Max
You may be interested in
Gamma Effect Max often compared
Glossary
Design for kids
This category includes nebulisers made in a characteristic "childish" design. Such a design may include bright colours, additional decorative details (for example, in the form of figurines) and even the original shape of the entire body of the nebuliser — in the form of an animal, a fairy-tale castle, etc. Also included are models that are regularly produced in the "adult" version, but also have a "childish" colour version.
Medicine container
The nebuliser's built-in medicine reservoir volume is a crucial consideration. It's important to align this parameter with medical guidelines for the prescribed treatment. A too-small capacity may require frequent refilling, disrupting the treatment process.
Also, knowing the volume of the reservoir and the nebulization rate (see below), it is possible to estimate the operating time of the nebuliser on a single refill.
Also, knowing the volume of the reservoir and the nebulization rate (see below), it is possible to estimate the operating time of the nebuliser on a single refill.
Max air flow
The maximum air output of a compressor nebuliser during operation is a key factor to consider. It's important to note that actual performance during normal operation is often lower. Different applications have recommended air flow intensities, and knowing this parameter helps assess how well the inhaler aligns with specific recommendations.
Nebulization rate
The nebuliser's nebulization capacity per minute.
The ideal nebulization rate can differ based on factors such as the patient's health condition, the type of disease, and the composition of the inhaled medication, as outlined in medical guidelines. This rate is crucial in assessing the inhaler's effectiveness for specific situations and also influences how long the device operates on a single medication refill.
Some models have a nebulization speed control — in such cases, the maximum value is usually indicated in the characteristics.
The ideal nebulization rate can differ based on factors such as the patient's health condition, the type of disease, and the composition of the inhaled medication, as outlined in medical guidelines. This rate is crucial in assessing the inhaler's effectiveness for specific situations and also influences how long the device operates on a single medication refill.
Some models have a nebulization speed control — in such cases, the maximum value is usually indicated in the characteristics.
Particle size
The aerosol generated by a nebuliser contains droplets of varying sizes. Smaller droplets have an easier time reaching the narrow passages of the bronchi, delivering the medicinal substance deeper into the respiratory system. For optimal therapeutic effects, it is recommended that droplet sizes do not surpass 5 microns. It's worth noting that during the atomization process, particles may vary in size, and their values are often expressed as a range.
Medium particle size (MMAD)
Since not all particles have the same size, this paragraph indicates exactly the average, most common particle size when splitting in this inhaler. Accordingly, lower values allow easier and deeper penetration into the bronchi.
















