Comparison Blauberg Bravo 125 vs Blauberg Aero 125

Add to comparison
Blauberg Bravo (125)
Blauberg Aero (125)
Blauberg Bravo 125Blauberg Aero 125
from $60.96
Outdated Product
from $60.96 up to $73.12
Outdated Product
TOP sellers
Main
The manufacturer's warranty is 5 years.
Typedomestic extractiondomestic extraction
Mounting diameter125 mm125 mm
Specs
Type of bearingball bearingball bearing
Air flow (extraction)192 m³/h193 m³/h
Rotational speed2400 rpm2400 rpm
Supply voltage230 V230 V
Power consumption16 W16 W
Features
non-return valve / shutters
non-return valve / shutters
General specs
Noise level37 dB39 dB
Protection levelIP34IP34
Country of originGermanyGermany
Cover height176 mm168 mm
Cover width176 mm168 mm
Cover thickness17 mm30 mm
Cover materialplasticplastic
Mounting depth (duct)87 mm67 mm
Dimensions (LxWxH)104x176x176 mm
Color
Added to E-Catalogjanuary 2015january 2015

Air flow (extraction)

This parameter describes the amount of air that the fan can pass through itself per hour when operating in extraction mode (see "Type"). It is one of the key characteristics of any extractor fan — it characterizes the overall performance and suitability of the unit for a particular room.

When choosing a fan for maximum performance, two main indicators must be taken into account — the volume of the room and the air flow rate. The volume can be found by multiplying the area of the room by the height of the ceilings: for example, for a room of 12 m² in a residential apartment with standard ceilings of 2.5 m, this figure will be 12x2.5=30 m³. The air flow rate describes how many times per hour the air in an enclosed space must be completely replaced for ventilation to be sufficiently effective. This multiplicity is different for different types of premises: in particular, for the kitchen, it is 6-8, for the bathroom — 8-10, etc. More detailed values be found in specialized sources, in particular, sanitary standards. And the minimum required fan performance is calculated by multiplying the air volume by the air exchange rate. For example, if we have a bathroom with an area of 4 m² with the same ceiling of 2.5 m, then the volume of air in it will be 4x2=10 m³; Considering that the minimum air exchange rate for bathrooms is 7, for this room we need a fan with a capacity of at least 70 m³/h.

Noise level

The noise level reproduced by the fan in normal operation.

The lower the noise level, the more comfortable the use of the fan will be, the better it is suitable for rooms in which it is desirable to keep silence. In addition, there are certain regulations written in sanitary standards (for example, for residential premises during the day, a constant noise level of up to 40 dB is considered acceptable, and at night — up to 30 dB).

When choosing according to specific values recorded in the characteristics, it should be taken into account that the decibel used to measure the noise level is not a linear quantity: for example, an increase in sound power by 2 times corresponds to an increase of 3 dB, 10 times — by 10 dB, 100 times — by 20 dB. Therefore, to assess the noise level, it is easiest to refer to comparative tables, where the correspondence of specific values in decibels to various real sound sources is recorded. In most modern fans, noise is between 20 and 60 dB, here is the simplest table for this range:

20 – 25 dB — a weak audible sound, comparable to a whisper at a distance of 1 – 2 m;
25 – 30 dB — intelligible whisper at a short distance, ticking of a wall clock;
35 dB — muffled conversation;
40 – 45 dB — normal human speech;
50 – 55 dB — talking in raised tones, noise in the office;
60 dB — loud conversation at a distance of several metres.

Note that patter...ns over 50 dB are rare; usually, these are “industrial” class units with a 400 V power supply and a large mounting diameter (see above), not intended for residential premises.

Cover height

The size of the decorative fan cover in height.

For details on the features of such panels in different types of fans, see "Cover diameter". The same size is indicated in cases where the panels are in the shape of a square or rectangle (see "Cover shape").

Cover width

The size of the decorative fan cover in width.

For details on the features of such panels in different types of fans, see "Cover diameter". The same size is indicated in cases where the panels are in the shape of a square or rectangle (see "Cover shape").

Cover thickness

The size of the decorative fan cover in thickness.

This parameter describes how much such a panel protrudes above the surface of the wall or ceiling on which the fan is installed. For more information about the general features of decorative panels in different types of fans, see "Cover diameter".

Mounting depth (duct)

Mounting depth of the fan with a standard installation method.

This parameter describes how deep into the duct the unit (or its parts in the case of surface-mounted models, see "Type") is placed during installation. Knowing the mounting depth, it is possible to assess the suitability of the selected model for a particular installation location: a flat section at the very beginning of the duct must be no less than the installation depth of the selected fan.

The smallest value of this parameter is typical for some overhead models of fans: in them, the main part of the structure is outside, and usually, only 2-3 centimetres are required for installation. And most of all, hidden units require space (see "Type").