Dark mode
United Kingdom
Catalog   /   Climate, Heating, Water Heating   /   Heating & Cooling   /   Extractor Fans

Comparison Soler&Palau SILENT-DESIGN SILENT-100 CRZ DESIGN vs Soler&Palau SILENT SILENT-100 CRZ

Add to comparison
Soler&Palau SILENT-DESIGN (SILENT-100 CRZ DESIGN)
Soler&Palau SILENT (SILENT-100 CRZ)
Soler&Palau SILENT-DESIGN SILENT-100 CRZ DESIGNSoler&Palau SILENT SILENT-100 CRZ
from $63.94 up to $103.68
Outdated Product
from $58.80 up to $81.60
Outdated Product
TOP sellers
Main
Sleep timer. Light indication of work. Protected against water jets. Low noise level. Economical power consumption.
Impeller with aerodynamic properties. Ball bearing motor. Thermal protection. High class of case insulation and water protection. Economical power consumption. Low noise and vibration.
Typedomestic extractiondomestic extraction
Mounting diameter100 mm100 mm
Specs
Type of bearingball bearingball bearing
Air flow (extraction)85 m³/h95 m³/h
Rotational speed2400 rpm2400 rpm
Supply voltage230 V230 V
Power consumption8 W8 W
Features
non-return valve / shutters
timer
non-return valve / shutters
timer
General specs
Timer adjustment1 – 30 min1 – 30 min
Noise level27 dB27 dB
Protection levelIP45IP45
Country of originSpainSpain
Perimeter suction
Cover height188 mm158 mm
Cover width188 mm158 mm
Cover thickness45 mm24 mm
Cover materialplasticplastic
Mounting depth (duct)85 mm85 mm
Dimensions (LxWxH)130x188x188 mm109x158x158 mm
Color
Added to E-Catalogjanuary 2015january 2015

Air flow (extraction)

This parameter describes the amount of air that the fan can pass through itself per hour when operating in extraction mode (see "Type"). It is one of the key characteristics of any extractor fan — it characterizes the overall performance and suitability of the unit for a particular room.

When choosing a fan for maximum performance, two main indicators must be taken into account — the volume of the room and the air flow rate. The volume can be found by multiplying the area of the room by the height of the ceilings: for example, for a room of 12 m² in a residential apartment with standard ceilings of 2.5 m, this figure will be 12x2.5=30 m³. The air flow rate describes how many times per hour the air in an enclosed space must be completely replaced for ventilation to be sufficiently effective. This multiplicity is different for different types of premises: in particular, for the kitchen, it is 6-8, for the bathroom — 8-10, etc. More detailed values be found in specialized sources, in particular, sanitary standards. And the minimum required fan performance is calculated by multiplying the air volume by the air exchange rate. For example, if we have a bathroom with an area of 4 m² with the same ceiling of 2.5 m, then the volume of air in it will be 4x2=10 m³; Considering that the minimum air exchange rate for bathrooms is 7, for this room we need a fan with a capacity of at least 70 m³/h.

Perimeter suction

A suction system that draws in air through a series of holes around the perimeter of the air intake. This design provides high suction efficiency and, at the same time, allows you to apply advanced design solutions to the device. Perimeter suction is characteristic mainly of models of the upper price range.

Cover height

The size of the decorative fan cover in height.

For details on the features of such panels in different types of fans, see "Cover diameter". The same size is indicated in cases where the panels are in the shape of a square or rectangle (see "Cover shape").

Cover width

The size of the decorative fan cover in width.

For details on the features of such panels in different types of fans, see "Cover diameter". The same size is indicated in cases where the panels are in the shape of a square or rectangle (see "Cover shape").

Cover thickness

The size of the decorative fan cover in thickness.

This parameter describes how much such a panel protrudes above the surface of the wall or ceiling on which the fan is installed. For more information about the general features of decorative panels in different types of fans, see "Cover diameter".
Soler&Palau SILENT-DESIGN often compared
Soler&Palau SILENT often compared