Comparison DigiTOP V-protector VP-10AN vs DigiTOP V-protector VP-10AS

Add to comparison
DigiTOP V-protector VP-10AN
DigiTOP V-protector VP-10AS
DigiTOP V-protector VP-10ANDigiTOP V-protector VP-10AS
Outdated ProductOutdated Product
TOP sellers
Devicevoltage Monitoring Relaysvoltage Monitoring Relays
Voltagevariablevariable
Number of phases11
Mountinto socketinto socket
Specs
Power2.2 kVA2.2 kVA
Maximum current10 А10 А
Voltage measuring range100 – 400 V50 – 400 V
Measurement accuracy (±)2.2 %2.2 %
Cut-off time (lower limit)0.02 с0.02 с
Off time (upper limit)0.02 с0.02 с
Reclosing delay5 – 600 с5 – 600 с
Lower cut-off limit120 – 200 V120 – 200 V
Upper cut-off limit210 – 270 V210 – 270 V
Functions
display
 
 
display
operation indicator
fault memory
General
Adjustmentdigitaldigital
Protection levelIP20IP20
Added to E-Catalogdecember 2017december 2017

Voltage measuring range

Voltage measurement range supported by the device.

Many modern control relays are equipped with digital displays, which can display, including current voltage; this parameter specifies the operating range of the built-in voltmeter. In this case, the voltage measurement range can be noticeably wider than the difference between the smallest minimum and the largest maximum shutdown threshold (see below). This allows you to use the relay also for online diagnostics of the network status.

For a current relay (see "Device") in this case, the range of operating voltages can be given directly — the voltage at which the device can normally perform its functions.

Functions

Display. As a rule, control relays are equipped with simple segment LCD displays that can display numbers and some special characters. This screen performs two main functions. Firstly, during operation it displays key network parameters - voltage, power and/or power, as well as notifications of problems; Some models provide several separate displays, each with its own parameter. Secondly, the screen is used when changing device settings.

Operation indicator. A pointer indicating the operation of a device, and often a specific mode of operation. Note that in this case we are talking about the simplest indicators - for example, in the form of an LED, which lights up green in normal mode and lights up red after the protection is triggered. The display is not considered an operation indicator, although it can perform such a function.

Thermal protection. A safety system that turns off the device when it reaches a critical temperature. Some models also provide a shutdown when the permissible heating rate is exceeded. This function serves as additional insurance in case of malfunctions in the relay itself (for example, if the settings are lost and the device does not respond to overload), and in case of fire (in case of fire, the equipment must be de-energized).

Memory of emergency operations. The function...of saving data on the state of the network during emergencies. Allows you to assess the situation of what happened after resuming work.