United Kingdom
Catalog   /   Computing   /   Networking   /   Switches

Comparison Bolid SW-108 vs Dahua DH-PFS3110-8P-96

Add to comparison
Bolid SW-108
Dahua DH-PFS3110-8P-96
Bolid SW-108Dahua DH-PFS3110-8P-96
Outdated ProductOutdated Product
TOP sellers
Typeunmanagedunmanaged
MountdIN-rail mount
dIN-rail mount /on DIN rail/
Ports
Fast Ethernet88
Gigabit Ethernet11
SFP (optics)11
PoE
PoE (output)802.3af/at802.3af/at
PoE outputs88
PoE output power30 W30 W
Total PoE power93 W96 W
General
PSUexternalexternal
Operating temperature-30 °C ~ +65 °C
Dimensions (WxDxH)42x100x150 mm150x100x42 mm
Weight540 g540 g
Added to E-Catalogmarch 2019january 2018

Total PoE power

The total output power provided by the switch when powering devices using the PoE standard (see above).

This indicator usually corresponds to the sum of the powers of all outputs — that is, the power of one PoE port, multiplied by their total number. However, the power limits for one output and for the entire switch are somewhat different: if a load with a power equal to the output power of the power supply on this connector can be connected to a single connector, then the total power consumption of all devices connected via PoE should ideally not exceed 75% of the total power supply — this gives an additional guarantee in case of malfunctions. In fact, this means that all PoE outputs cannot be used “to the fullest” at the same time. For example, if there are two such outputs, and one is loaded at 100%, then the second can be loaded with a maximum of 50% — the total power consumption in this case will be the same 75% of the total output. Therefore, a large total power is needed when using the device to the maximum.

Operating temperature

The range of operating temperatures allowed for the switch, in other words, the air temperature at which the device is guaranteed to remain operational.

All modern switches are able to normally endure conditions that are comfortable for a person. Therefore, you should pay attention to this indicator, first of all, in cases where the conditions at the installation site of the switch will differ markedly from home / office; a typical example is the placement of ISP equipment in the attic of a multi-storey building. At the same time, special attention should be paid to the lower limit of the temperature range — not every device is able to operate at sub-zero temperatures. If we talk about specific numbers, then for an unheated room frost resistance is desirable at least at the level of -5 °C, and ideally — — 20 °C(although, of course, this also depends on the climate).

Also note that, in addition to temperature, most switches have restrictions on the relative humidity of the air; these restrictions are usually specified in the documentation.
Dahua DH-PFS3110-8P-96 often compared