Dark mode
United Kingdom
Catalog   /   Computing   /   Networking   /   Switches

Comparison TP-LINK TL-SF1008P vs Zyxel ES1100-8P

Add to comparison
TP-LINK TL-SF1008P
Zyxel ES1100-8P
TP-LINK TL-SF1008PZyxel ES1100-8P
Compare prices 12Compare prices 1
TOP sellers
Typeunmanagedunmanaged
Mountdesktopdesktop
Bandwidth1.6 Gbps
MAC address table size1K
Ports
Fast Ethernet88
PoE
PoE (output)802.3af802.3af
PoE outputs48
PoE output power15 W15 W
Total PoE power57 W130 W
General
PSUexternalbuilt-in
Supply voltage48 В
Operating temperature0 °C ~ +40 °C
Dimensions (WxDxH)171x98х27 mm262x184х41 mm
Weight1400 g
Added to E-Catalogseptember 2014september 2014

Bandwidth

The bandwidth of a switch is the maximum amount of traffic that it can handle. Specified in gigabits per second.

This parameter directly depends on the number of network ports in the device (excluding Uplink). Actually, even if the bandwidth is not given in the specifications, it can still be calculated using the following formula: the number of ports multiplied by the bandwidth of an individual port and multiplied by two (since both incoming and outgoing traffic are taken into account). For example, a model with 8 Gigabit Ethernet connectors and 2 SFP ports will have a bandwidth of (8*1 + 2*1)*2 = 20 Gbps.

The choice for this indicator is quite obvious: you need to evaluate the expected traffic volumes in the serviced network segment and make sure that the switch's bandwidth will cover it with a margin of at least 10-15% (this will give an additional guarantee in case of emergency situations). At the same time, if you plan to often work at high, close to maximum, loads, it will not hurt to clarify such a characteristic as the internal bandwidth of the switch. It is usually given in a detailed technical description, and if this value is less than the total throughput, serious problems may arise under significant loads.

MAC address table size

The maximum number of MAC addresses that can be stored in the Switch's memory at the same time. Specified in thousands, for example, 8K — 8K.

Recall that the MAC address is the unique address of each individual network device used in physical routing (at layer 2 of the OSI network model). Switches of all types work with such addresses. And it is worth choosing a switch according to the size of the table, taking into account the maximum number of devices that are supposed to be used with it (including based on the possible expansion of the network). If the table is not enough, the switch will overwrite new addresses over the old ones, which can noticeably slow down the work.

PoE outputs

The number of PoE-enabled outputs (see above) provided in the design of the switch. This number corresponds to the maximum number of PoE network devices that can be connected to this model at the same time.

Total PoE power

The total output power provided by the switch when powering devices using the PoE standard (see above).

This indicator usually corresponds to the sum of the powers of all outputs — that is, the power of one PoE port, multiplied by their total number. However, the power limits for one output and for the entire switch are somewhat different: if a load with a power equal to the output power of the power supply on this connector can be connected to a single connector, then the total power consumption of all devices connected via PoE should ideally not exceed 75% of the total power supply — this gives an additional guarantee in case of malfunctions. In fact, this means that all PoE outputs cannot be used “to the fullest” at the same time. For example, if there are two such outputs, and one is loaded at 100%, then the second can be loaded with a maximum of 50% — the total power consumption in this case will be the same 75% of the total output. Therefore, a large total power is needed when using the device to the maximum.

PSU

— Built-in. The built-in power supply does not take up space on the outside, but can significantly increase the size and weight of the entire switch. Because of this, this option is quite rare — mainly among rack-mount models (see "Form factor"), where an external unit can create significant inconvenience, as well as among the most powerful desktop switches, for which restrictions on dimensions and weight is not critical.

— External. Theoretically , an external power supply requires additional space, and therefore is not as convenient as an internal one. In fact, most blocks of this type are quite compact in size and are equipped with “plugs” for sockets right on the case — in other words, the block is installed on a socket, and from there the wire stretches to the switch. And the absence of power circuits and transformers inside the case has a positive effect on compactness. Thanks to all this, this option is very popular among desktop models (see "Form factor"), primarily entry-level and mid-level.

— No BP. The absence of a power supply both in the design and in the delivery set is a rather rare case found in three types of switches. The first variety is models that use PoE power (see above) and do not require separate power sources. PoE power is relatively small, so relatively simple devices with a small number of ports fall into this category. The second variety is professional switc...hes, the power supplies for which are sold as separately installed internal modules; such equipment may even provide the possibility of using two PSUs simultaneously (main and backup) and hot-swapping them. The third type — switches with installation on a DIN rail (see "Form factor") and having terminals for connecting a specialized external power source.

Supply voltage

The amount of voltage required by the switch for uninterrupted operation. The power supply voltage of network equipment can vary from 5 V to 230 V, which allows you to power compatible devices from either a low-voltage USB socket on your computer or a standard household outlet. Values in the middle assume that the switch is powered by the appropriate power supply.

Operating temperature

The range of operating temperatures allowed for the switch, in other words, the air temperature at which the device is guaranteed to remain operational.

All modern switches are able to normally endure conditions that are comfortable for a person. Therefore, you should pay attention to this indicator, first of all, in cases where the conditions at the installation site of the switch will differ markedly from home / office; a typical example is the placement of ISP equipment in the attic of a multi-storey building. At the same time, special attention should be paid to the lower limit of the temperature range — not every device is able to operate at sub-zero temperatures. If we talk about specific numbers, then for an unheated room frost resistance is desirable at least at the level of -5 °C, and ideally — — 20 °C(although, of course, this also depends on the climate).

Also note that, in addition to temperature, most switches have restrictions on the relative humidity of the air; these restrictions are usually specified in the documentation.
TP-LINK TL-SF1008P often compared
Zyxel ES1100-8P often compared