Dark mode
United Kingdom
Catalog   /   Climate, Heating, Water Heating   /   Heaters   /   Oil Radiators

Comparison Gorenje OR 2000 MM 9 section
2 kW
vs FIRST Austria FA 5582-5 9 section
2.2 kW

Add to comparison
Gorenje OR 2000 MM 9 section 2 kW
FIRST Austria FA 5582-5 9 section 2.2 kW
Gorenje OR 2000 MM 9 section
2 kW
FIRST Austria FA 5582-5 9 section
2.2 kW
Outdated Product
from $62.16 up to $73.96
Outdated Product
TOP sellers
Main
High heat dissipation. Rotary control for selecting power modes.
High power. Rotary control for selecting power modes. Handle and wheels for easy transport.
Typeoil Radiatorsoil Radiators
Heating elementspiralspiral
Controlsrotary knobrotary knob
Power supplymainsmains
Max. power2000 W2200 W
Heating area20 m²22 m²
Number of fins99
Features
Features
thermostat
thermostat
Heating modes
3
 
Safety system
overheat protection
overheat protection
More specs
Installation
floor
floor
Wheels
Dimensions (HxWxD)64x42.5x28 cm
Color
Added to E-Catalogseptember 2018september 2015

Max. power

The maximum power of the heater. The meaning of this parameter depends on the device type and power supply (see above). So, for most types of heaters, we are talking about the highest power output. However, for fan heaters, this parameter also includes the power of the fan motor, and the heating capabilities are somewhat more modest than the claimed maximum power (although not by much). For electric models, the maximum power also corresponds to the maximum power consumption, which determines the connection requirements: for example, for devices of 3.5 kW and more, ordinary sockets are no longer suitable, and some require not 230 V but 400 V.

However, the key point determined by the power of the heater, is the intensity of heating and the ability to effectively heat a particular room. To select the appropriate model, there are special formulas. So, if we are talking about a city apartment or a small office space with a ceiling height of about 2.5 m, then we can assume that a heating power of at least 100 W is required per 1 m² of area. For other situations, more complex methods are used, taking into account the volume of the room, the degree of thermal insulation, climate and solar heating, etc.; they can be found in special sources. Also note that for IR heaters (see "Type"), their own calculation methods are used — this is due to the specific format of work.

Heating area

A very conditional parameter that slightly characterizes the purpose based on the size of the room. And depending on the height of the ceilings, layout and equipment, actual values may vary significantly. However, this item represents the maximum recommended area of the room that the device can effectively heat. This parameter directly depends on the maximum power (see above). It is worth noting that the actual efficiency of the heater in most cases depends not on the area, but on the volume of the room. In light of this, the heating area can only be specified for a certain ceiling height. In most cases, manufacturers mean 2.5 m - this is the standard ceiling height in city apartments. If the ceilings are much higher, the heating area must be recalculated using special formulas. In general, it is worth considering that 1 kW is comfortable for 10 m², however, manufacturers may slightly overestimate the heating area data.

Heating modes

The ability to adjust the power of the heater. Do not confuse this parameter with temperature control since several power modes primarily affect the heating rate, energy consumption and device wear.
Gorenje OR 2000 MM often compared