Dark mode
United Kingdom
Catalog   /   Small Appliances   /   Health & Rehabilitation   /   Blood Glucose Monitors

Comparison Bionime Rightest GM 110 vs Bionime Rightest GM 300

Add to comparison
Bionime Rightest GM 110
Bionime Rightest GM 300
Bionime Rightest GM 110Bionime Rightest GM 300
from $17.20 up to $23.12
Outdated Product
from $22.40 up to $25.68
Outdated Product
TOP sellers
Typeelectrochemicalelectrochemical
Measuring duration8 с8 с
Memory capacity150 measurements300 measurements
Measurements
Measurements
glucose
glucose
Additional modes
test
 
Averaging
in a day
in a week
in 14 days
in a month
in a day
in a week
in 14 days
in a month
Specs
Measurement range0.6 - 33.3 mmol/l0.6 - 33.3 mmol/l
Sample volume1.4 µl1.4 µl
Hematocrit30 - 55 %30 - 55 %
Encodingautomaticautomatic
Blood samplecapillarycapillary
Features
date and time
alert
auto switch-off
date and time
alert
auto switch-off
In box
Test strips10 pcs10 pcs
Test strip modelGS300GS300
Lancets10 pcs10 pcs
Lancet device
Cover/case
General
Calibrationplasmaplasma
Displaymonochromemonochrome
Power source1xCR20322xAAA
Dimensions95x43.8x13 mm85x55x22 mm
Weight43 g85 g
Added to E-Catalogfebruary 2017february 2017

Memory capacity

The maximum number of test results that a blood glucose monitor can store at once is crucial for monitoring changes in blood composition. The built-in memory of blood glucose monitors is highly convenient, automatically saving data without requiring extra steps from the user. Additionally, many devices can enhance measurement results with supplementary information, including date, time, and food markers.

Knowing the frequency of measurements and the amount of memory, you can determine how long this memory will last before overflowing. For example, if the device is designed for 500 results, and measurements are taken 4 times a day, then measurements can be stored in the built-in memory for 500/4 — 125 days, that is, about 4 months.

Additional modes

Test. To verify the functionality and accuracy of a blood glucose monitor, a control solution test is typically performed. This involves applying two control solutions with known glucose concentrations to the strips instead of blood. If the blood glucose monitor readings align with the expected values of the solutions, it indicates proper functionality. Periodic performance tests, ideally conducted weekly, are recommended, especially in cases of doubt about measurement results, such as discrepancies with one's health status.

No food intake. The mode of measuring blood counts on an empty stomach, before meals. It is used, in particular, to diagnose diabetes in the early stages, as well as to evaluate the effectiveness of drug-free (with the help of a diet) treatment of type 1 diabetes. Analysis data is stored in memory marked "on an empty stomach"; this allows you to track the trend over time.

— After eating. The mode of measuring blood parameters "on a full stomach", after eating. It is used, in particular, in insulin-dependent diabetes — to evaluate the effectiveness and correct the current dosage of insulin. The measurement results are stored in memory marked "after eating" in order to make it easier to track changes over a certain period of time.

Power source

The power source provided in the device.

CR2032. A slim "coin" battery, measuring 2 mm in thickness and 3.2 cm in diameter, is suitable for compact devices, including the smallest ones. While its capacity is less than that of AAA cells (refer to the relevant section), it remains sufficient for modern glucometers due to their low power consumption. Notably, some devices use two of these batteries to extend their overall battery life.

AAA. "Little" batteries, smaller than "AA" batteries but with a comparable design, are ideal for compact devices.

Battery. Operated by an internal, often non-removable battery, eliminating the need for regular battery purchases and replacements. However, in the event of a depleted battery, replacing it with a spare is a quick solution, while recharging requires time and a power source. Consequently, this option is not widely favored.

Mains. Operates by connecting to a 230 V household network, ensuring a constant power supply without concerns about battery depletion. However, glucometers, being primarily portable devices, are seldom equipped with mains power capabilities.
Bionime Rightest GM 110 often compared
Bionime Rightest GM 300 often compared