Comparison APC Smart-UPS 1000VA SMT1000RMI2U 1000 VA vs APC Smart-UPS 1000VA SUA1000RMI2U 1000 VA

Add to comparison
APC Smart-UPS 1000VA SMT1000RMI2U 1000 VA
APC Smart-UPS 1000VA SUA1000RMI2U 1000 VA
APC Smart-UPS 1000VA SMT1000RMI2U 1000 VAAPC Smart-UPS 1000VA SUA1000RMI2U 1000 VA
from £1,175.99 
Outdated Product
from $724.00 up to $1,061.40
Outdated Product
TOP sellers
Typesmartsmart
Form factorRackRack
Full load operating time8.7 min9.1 min
Half load operating time31.3 min30 min
Switching to battery2 ms
Input
Input voltage1 phase (230V)1 phase (230V)
Input voltage range151 – 302 V160-280 V
Max. current6 А
Bypass (direct connection)is absentis absent
Output
Output voltage1 phase (230V)1 phase (230V)
Peak output power1000 VA1000 VA
Rated output power700 W670 W
Output voltage accuracy5 %5 %
Efficiency98.2 %
Output waveformpure sine wave (PSW)pure sine wave (PSW)
Output frequency47 – 63 Hz47-63 Hz
Reserved C13/C14 connectors44
Battery
Total battery capacity7 Ah7 Ah
Number of batteries44
Full charge time180 min180 min
Cold start
Protection
Protection
short circuit protection
overload protection
noise filtering
 
 
sound alarm
short circuit protection
overload protection
noise filtering
data line protection
emergency cut-off socket
sound alarm
Fuseauto
Surge protection459 J480 J
Control interfaces
 
USB
LAN
SmartSlot
RS-232
USB
 
SmartSlot
General
Operating temperature0 – 40 °C0 – 40 °C
Noise level45 dB36 dB
Dimensions (HxWxD)85x480x475 mm89x432x457 mm
Height (unit)2 U2 U
Weight28.18 kg28.18 kg
Added to E-Catalogjuly 2019april 2012

Full load operating time

UPS continuous operation time from a fully charged battery when connected to a load with a power equal to the UPS output power (maximum or effective, depending on the type of load, see the relevant paragraphs for details). For a UPS designed to work with a home or office PC, a time of about 10-15 minutes is considered sufficient, this is enough to save data and complete work. To power servers, it is worth using devices with an operating time of 20 minutes or more.

Half load operating time

UPS continuous operation time from a fully charged battery when connected to a load with a power equal to half the output power of the UPS (maximum or effective, depending on the type of load, see below for details). The operating time with such a load is much longer than for a full load, and even in the simplest models it can reach 20-30 minutes.

Switching to battery

The time required to transfer the load from mains power to battery power. In standby and interactive UPSs (see Type), a short-term power failure occurs at this moment — accordingly, the shorter the time to switch to the battery, the more uniform the power supply is provided by the source during a power failure. Ideally, the switching time for the traditional 50 Hz AC frequency should be less than 5 ms (a quarter of one cycle of the sine wave). With inverter UPSs, the transfer time is, by definition, zero.

Input voltage range

In this case, the input voltage range is implied, in which the UPS is able to supply a stable voltage to the load only due to its own regulators, without switching to the battery. For redundant UPSs (see "Type") this range is quite small, approximately 190 to 260 V; for interactive and especially inverter ones, it is much wider. Some UPS models allow you to manually set the input voltage range.

Max. current

The maximum current drawn by the UPS. In fact, the current reaches its maximum value only when the UPS is operating from the mains with maximum load power and a completely discharged battery. However, when calculating the load on the power grid, this parameter should be taken into account.

Rated output power

The effective output power of the UPS is, in fact, the maximum active power of the load that can be connected to the device.

Active power is consumed directly for the operation of the device; it is expressed in watts. In addition to it, most AC devices also consume reactive power, which is "wasted" (relatively speaking) is spent by coils and capacitors. Apparent power (denoted in volt-amperes) is precisely the sum of active and reactive power; it is this characteristic that should be used in accurate electrical calculations. See "Maximum output power" for details; here we note that when selecting a UPS for a relatively simple application, it is quite possible to use only effective power. This is at least easier than converting the watts claimed in the characteristics of the connected devices into full power volt-amps.

The most modest modern "uninterruptibles" give out less than 500 watts. 501 – 1000 W can be considered an average value, 1.1 – 2 kW is above average, and in the most powerful models this figure exceeds 2 kW and can reach very impressive values (up to 1000 kW or more in some industrial class UPS).

Efficiency

Efficiency (coefficient of performance) in the case of a UPS is the ratio of its output power to the power consumed from the network. This is one of the main parameters that determine the overall efficiency of the device: the higher the efficiency, the less energy the UPS wastes (due to heating parts, electromagnetic radiation, etc.). In modern models, the efficiency value can reach 99%.

Output frequency

The frequency (frequency range) of the AC voltage output by the UPS. For computer technology, the frequency range of 47-53 Hz is considered normal, although the smaller the deviation from the 50 Hz standard, the better. On the other hand, in some UPS models, this frequency can be automatically synchronized with the frequency of the mains — so the power supplied to the load will not differ regardless of whether the load is powered by the mains or from the battery. In this case, a wider frequency range, on the contrary, is more desirable.

Cold start

The ability to turn on the uninterruptible power supply in the "cold start" mode.

A cold start is a turn-on mode in which there is no external power, and the load connected to the UPS is powered immediately from the uninterruptible battery (which, of course, must be charged). This mode is especially useful in emergency cases — for example, if you urgently need to print a document, but there is no light.