Comparison APC Smart-UPS C 1500VA SMC1500I-2U 1500 VA vs APC Smart-UPS 1500VA SMT1500RMI1U 1500 VA

Add to comparison
APC Smart-UPS C 1500VA SMC1500I-2U 1500 VA
APC Smart-UPS 1500VA SMT1500RMI1U 1500 VA
APC Smart-UPS C 1500VA SMC1500I-2U 1500 VAAPC Smart-UPS 1500VA SMT1500RMI1U 1500 VA
from £1,599.79 
Expecting restock
Compare prices 7
TOP sellers
Typesmartsmart
Form factorRackRack
Full load operating time7 min5 min
Half load operating time19 min17 min
Switching to battery2 ms
Input
Input voltage1 phase (230V)1 phase (230V)
Input voltage range170-300 V160-286 V
Bypass (direct connection)is absentis absent
Output
Output voltage1 phase (230V)1 phase (230V)
Peak output power1500 VA1500 VA
Rated output power900 W1000 W
Output voltage accuracy5 %5 %
Efficiency
98.3 % /at full load/
Output waveformpure sine wave (PSW)pure sine wave (PSW)
Output frequency50-60 Hz
57-63 Hz /synchronized with the mains/
Reserved C13/C14 connectors44
Battery
Total battery capacity7 Ah
Number of batteries41
Full charge time180 min180 min
Cold start
Protection
Protection
short circuit protection
overload protection
noise filtering
 
 
sound alarm
short circuit protection
overload protection
noise filtering
data line protection
emergency cut-off socket
sound alarm
Surge protection459 J459 J
Control interfaces
USB
LAN
 
USB
 
SmartSlot
General
Screen
Operating temperature0 – 40 °C0 – 40 °C
Noise level46 dB46 dB
Dimensions (HxWxD)89x432x457 mm44x432x665 mm
Height (unit)2 U1 U
Weight28.64 kg24 kg
Added to E-Catalogfebruary 2016may 2015

Full load operating time

UPS continuous operation time from a fully charged battery when connected to a load with a power equal to the UPS output power (maximum or effective, depending on the type of load, see the relevant paragraphs for details). For a UPS designed to work with a home or office PC, a time of about 10-15 minutes is considered sufficient, this is enough to save data and complete work. To power servers, it is worth using devices with an operating time of 20 minutes or more.

Half load operating time

UPS continuous operation time from a fully charged battery when connected to a load with a power equal to half the output power of the UPS (maximum or effective, depending on the type of load, see below for details). The operating time with such a load is much longer than for a full load, and even in the simplest models it can reach 20-30 minutes.

Switching to battery

The time required to transfer the load from mains power to battery power. In standby and interactive UPSs (see Type), a short-term power failure occurs at this moment — accordingly, the shorter the time to switch to the battery, the more uniform the power supply is provided by the source during a power failure. Ideally, the switching time for the traditional 50 Hz AC frequency should be less than 5 ms (a quarter of one cycle of the sine wave). With inverter UPSs, the transfer time is, by definition, zero.

Input voltage range

In this case, the input voltage range is implied, in which the UPS is able to supply a stable voltage to the load only due to its own regulators, without switching to the battery. For redundant UPSs (see "Type") this range is quite small, approximately 190 to 260 V; for interactive and especially inverter ones, it is much wider. Some UPS models allow you to manually set the input voltage range.

Rated output power

The effective output power of the UPS is, in fact, the maximum active power of the load that can be connected to the device.

Active power is consumed directly for the operation of the device; it is expressed in watts. In addition to it, most AC devices also consume reactive power, which is "wasted" (relatively speaking) is spent by coils and capacitors. Apparent power (denoted in volt-amperes) is precisely the sum of active and reactive power; it is this characteristic that should be used in accurate electrical calculations. See "Maximum output power" for details; here we note that when selecting a UPS for a relatively simple application, it is quite possible to use only effective power. This is at least easier than converting the watts claimed in the characteristics of the connected devices into full power volt-amps.

The most modest modern "uninterruptibles" give out less than 500 watts. 501 – 1000 W can be considered an average value, 1.1 – 2 kW is above average, and in the most powerful models this figure exceeds 2 kW and can reach very impressive values (up to 1000 kW or more in some industrial class UPS).

Efficiency

Efficiency (coefficient of performance) in the case of a UPS is the ratio of its output power to the power consumed from the network. This is one of the main parameters that determine the overall efficiency of the device: the higher the efficiency, the less energy the UPS wastes (due to heating parts, electromagnetic radiation, etc.). In modern models, the efficiency value can reach 99%.

Output frequency

The frequency (frequency range) of the AC voltage output by the UPS. For computer technology, the frequency range of 47-53 Hz is considered normal, although the smaller the deviation from the 50 Hz standard, the better. On the other hand, in some UPS models, this frequency can be automatically synchronized with the frequency of the mains — so the power supplied to the load will not differ regardless of whether the load is powered by the mains or from the battery. In this case, a wider frequency range, on the contrary, is more desirable.

Total battery capacity

The capacity of the battery installed in the UPS. For models with multiple batteries, this is both the total working capacity and the capacity of each individual battery: the batteries in such devices are usually connected in series, so that their total capacity corresponds to the capacity of each individual cell.

Theoretically, a higher battery capacity means the ability to power loads of a given capacity for longer. However, in fact, this parameter is more of a reference than practically significant. The fact is that the actual amount of energy stored by the battery depends not only on the capacity in amp-hours, but also on the voltage in volts; this voltage is often not specified in the characteristics, despite the fact that for accurate calculations it must be known. So when choosing, you should focus on more "close to life" characteristics — first of all, on the directly claimed operating time in different modes (see above).

Number of batteries

The number of batteries supplied with the UPS.

In general, this parameter is more of a reference than practically significant: the number of batteries is selected in such a way as to provide the desired performance — primarily the time of continuous operation. First of all, it is worth paying attention to such characteristics when choosing.
APC Smart-UPS C 1500VA SMC1500I-2U often compared