Dark mode
United Kingdom
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   UPS

Comparison CyberPower BR700ELCD 700 VA vs Powercom RPT-1025AP Schuko 1025 VA

Add to comparison
CyberPower BR700ELCD 700 VA
Powercom RPT-1025AP Schuko 1025 VA
CyberPower BR700ELCD 700 VAPowercom RPT-1025AP Schuko 1025 VA
Compare prices 6
from $105.60 up to $117.96
Outdated Product
TOP sellers
Main
Interactive UPS. 4 euro sockets. Cold start. Quiet work.
Typesmartsmart
Form factorregular (extension)standard (Tower)
Switching to battery4 ms4 ms
Input
Input voltage1 phase (230V)1 phase (230V)
Input voltage range165-290 V165 – 300 V
Max. current3 А
Bypass (direct connection)is absentis absent
Output
Output voltage1 phase (230V)1 phase (230V)
Peak output power700 VA1025 VA
Rated output power420 W615 W
Output waveformsimilar to a sinusoid (approximated)similar to a sinusoid (approximated)
Output frequency50-60 Hz50/60 Hz
Redundant sockets44
Non-redundant sockets4
Socket typetype F (Schuko)type F (Schuko)
Charging USB A ports1
Battery
Total battery capacity7 Ah7 Ah
Number of batteries12
Battery typeGEL ( filled with gel)
Full charge time480 min240 min
Cold start
Protection
Protection
short circuit protection
overload protection
noise filtering
data line protection
sound alarm
short circuit protection
overload protection
noise filtering
data line protection
sound alarm
Fuseautoauto
Surge protection125 J
Control interfaces
USB
USB
General
Screen
Operating temperature0 – 40 °C0 – 40 °C
Noise level40 dB
Dimensions (HxWxD)118x288x166 mm164x146x360 mm
Weight5.3 kg8.4 kg
Added to E-Catalogoctober 2016july 2015

Form factor

Standard (Tower). UPS designed for floor mounting or placement on any suitable horizontal surface. This “installation” is extremely simple, and it is suitable even for the most powerful and heaviest devices, and therefore most modern uninterruptible power supplies (of all categories) are made in the usual Tower form factor. They are supposed to be placed vertically.

Rack. Models for installation in telecommunication racks. Most of these uninterruptible power supplies belong to the professional equipment segment, designed to power servers and other similar electronics (which are also often mounted in a similar way). The most common standard of racks is 19", however there are other options, so it would not hurt to check the compatibility of the UPS with a specific rack separately. We also note that models of this type are often equipped with legs that allow you to place the device on the floor “sideways” or in a vertical position. Display (if available) in such models may have a rotating design for ease of reading parameters in both positions.

Wall-mounted. Uninterruptible power supplies, primarily designed for wall mounting. Wall hanging may be the best option in tight spaces. However, such an installation is not the only option - many devices can optionally be installed on the floor. Also note that wall-mounted UPSs are often used for heating boile...rs. The main disadvantage of this form factor is the need to drill into the walls to install an uninterruptible power supply.

- Flat. UPS, structurally assembled in a low, flat housing. As a rule, this form factor allows for several options for installing equipment: the uninterruptible power supply can be installed horizontally or vertically. However, it is the horizontal method of installing the UPS that predominates. In fact, everything depends on the location of the uninterruptible power supply and its dimensions - it would not hurt to clarify this point separately.

Extension cord. Uninterruptible power supplies that resemble an extension cord in appearance. Structurally, such UPSs consist of a set of sockets in one housing, with the sockets located on the top platform of the uninterruptible power supply. Often, the housing of such UPSs is provided with holes or fasteners for wall mounting.

Input voltage range

In this case, the input voltage range is implied, in which the UPS is able to supply a stable voltage to the load only due to its own regulators, without switching to the battery. For redundant UPSs (see "Type") this range is quite small, approximately 190 to 260 V; for interactive and especially inverter ones, it is much wider. Some UPS models allow you to manually set the input voltage range.

Max. current

The maximum current drawn by the UPS. In fact, the current reaches its maximum value only when the UPS is operating from the mains with maximum load power and a completely discharged battery. However, when calculating the load on the power grid, this parameter should be taken into account.

Peak output power

The maximum output power supplied by the UPS, in other words, the highest apparent load power allowed for this model.

This indicator is measured in volt-amperes (the general meaning of this unit is the same as that of the watt, and different names are used to separate different types of power). The total power consumption of the load, implied in this case, is the sum of two powers — active and reactive. Active power is actually effective power (it is indicated in watts in the characteristics of electrical appliances). Reactive power is the power wasted by coils and capacitors in AC devices; with numerous coils and/or capacitors, this power can be a fairly significant part of the total energy consumption. Note that for simple tasks, you can use data on effective power (it is often given for UPS — see below); but for accurate electrical calculations it is worth using the full one.

The simplest selection rule for this indicator is: the maximum output power of the UPS in volt-amperes should be at least 1.7 times higher than the total load power in watts. There are also more detailed calculation formulas that take into account the characteristics of different types of load; they can be found in special sources. As for specific values, the most modest modern UPSs give out 700 – 1000 VA, or even less — this is enough to power a PC of average performance; and in the most "heavyweight" models, th...is figure can be 8 – 10 kVA and higher.

Rated output power

The effective output power of the UPS is, in fact, the maximum active power of the load that can be connected to the device.

Active power is consumed directly for the operation of the device; it is expressed in watts. In addition to it, most AC devices also consume reactive power, which is "wasted" (relatively speaking) is spent by coils and capacitors. Apparent power (denoted in volt-amperes) is precisely the sum of active and reactive power; it is this characteristic that should be used in accurate electrical calculations. See "Maximum output power" for details; here we note that when selecting a UPS for a relatively simple application, it is quite possible to use only effective power. This is at least easier than converting the watts claimed in the characteristics of the connected devices into full power volt-amps.

The most modest modern "uninterruptibles" give out less than 500 watts. 501 – 1000 W can be considered an average value, 1.1 – 2 kW is above average, and in the most powerful models this figure exceeds 2 kW and can reach very impressive values (up to 1000 kW or more in some industrial class UPS).

Output frequency

The frequency (frequency range) of the AC voltage output by the UPS. For computer technology, the frequency range of 47-53 Hz is considered normal, although the smaller the deviation from the 50 Hz standard, the better. On the other hand, in some UPS models, this frequency can be automatically synchronized with the frequency of the mains — so the power supplied to the load will not differ regardless of whether the load is powered by the mains or from the battery. In this case, a wider frequency range, on the contrary, is more desirable.

Non-redundant sockets

The number of outlets without connection to the power reserve provided in the design of the UPS. For devices connected to such outlets, the UPS only performs the function of a surge protector — it smooths out small voltage irregularities; when the mains voltage fails, the power to these outlets is also turned off. The sockets have a standard shape and are compatible with the vast majority of popular 230 V plugs. The presence of sockets without a reserve allows you to connect equipment with different requirements for uninterrupted power supply to one UPS. For example, sockets with a reserve (see above) can include a system unit and a monitor, and a printer can be connected to a socket without a reserve. Thus, if the mains power fails, the computer will continue to work, allowing you to save data, and the printer will turn off, thus saving battery power and providing longer UPS runtime.

Charging USB A ports

The number of USB A connectors provided in the UPS, designed to charge external devices, such as smartphones or tablets.

This number corresponds to the number of gadgets that can be simultaneously charged. True, it is worth considering that not every UPS with this function is able to charge USB devices from its own battery, without external power supply - it is better to check this possibility before buying.

Number of batteries

The number of batteries supplied with the UPS.

In general, this parameter is more of a reference than practically significant: the number of batteries is selected in such a way as to provide the desired performance — primarily the time of continuous operation. First of all, it is worth paying attention to such characteristics when choosing.
Powercom RPT-1025AP Schuko often compared