Dark mode
United Kingdom
Catalog   /   Photo   /   Binoculars & Telescopes   /   Spotting Scopes

Comparison Celestron C90 Mak vs Celestron Ultima 100/45

Add to comparison
Celestron C90 Mak
Celestron Ultima 100/45
Celestron C90 MakCelestron Ultima 100/45
Compare prices 3
from £423.00 
Outdated Product
TOP sellers
Main
The spyglass is equipped with an 8x21 straight image finder.
Magnification39 x22 – 66 x
Optical systemcatadioptric (Cassegrain)lens
Field of view 1 km away20.7 m31 – 17 m
Angle of view1.3 °1.8 – 1 °
Min. focus distance4.6 m10 m
Design
Lens diameter90 mm100 mm
Exit pupil diameter2.3 mm4.5 – 1.5 mm
Eye relief20 mm18 mm
Focusscrew on the casescrew on the case
Changeable eyepiece
Eyepiece locationat 45°at 45°
Anti reflective coatingmultilayermultilayer
Prism typePorroPorro
Prism materialBaK-4BaK-4
Digiscoping
Nitrogen filled
Shockproof
Dust-, waterproof
General
Case
Bodymetal
Dimensions400x260x260 mm483 mm
Weight2270 g2041 g
Added to E-Catalognovember 2017october 2016

Magnification

The magnification of the image provided by a telescope. Roughly speaking, this parameter describes how many times the object seen in the eyepiece of the pipe will be larger than when viewed from the same distance with the naked eye.

Multiplicity — the first number (numbers) in the digital marking of optical instruments: for example, the designation 25-75x50 corresponds to a multiplicity from 25x to 75x. Note that most modern telescopes have variable (adjustable) magnification. This allows you to choose the mode of operation depending on the situation: to search for the desired object, it is more convenient to reduce the magnification, providing a wide field of view, and having found it, increase the magnification and examine in detail. However in some models, to change the magnification, you need to replace the eyepiece (see "Replacement eyepiece").

High magnification, on the one hand, makes the tube "long-range" and makes it easy to examine small objects at considerable distances. On the other hand, the angle of view decreases in this case, which makes it difficult to observe moving objects and even aim the optics at the target. In addition, with an increase in the magnification, the diameter of the exit pupil also decreases (see below) and the aperture ratio of the tube; you can compensate for this moment by increasing the lens, but this accordingly affects the price. So it makes sense to specifically look for powerful optics with a high degree of ma...gnification only when such capabilities are fundamentally important.

Optical system

The type of optical system used in a telescope.

The optical system is a set of lenses and other elements responsible for processing the image entering the eyepiece. Such systems may be of the following types:

Lens. She's a refractor. Optical systems based solely on lenses. Such systems are relatively simple, inexpensive and at the same time quite functional. Image quality, however, turns out to be somewhat lower than in mirror-lens systems, and with a magnification factor of more than 60x, it deteriorates even more; therefore, lens systems usually have relatively low magnification. In addition, they are longer and heavier. On the other hand, optical devices of this design are quite unpretentious in handling and resistant to shock and shock (although this is still better to avoid); and the mentioned high multiplicity is rarely required in fact. Thus, most modern telescopes use this type of optic.

Mirror lens. This category includes optical systems built on the basis of concave mirrors (which provide the main increase) and corrective lenses designed to eliminate the distortion that inevitably occurs when using mirrors. One of the key advantages of such systems over lens systems is a clearer image, even at high magnifications — the magnification of telescopes of this type can reach 200x without compromising image quality. In addition, with the same focal length, the body o...f the device can be made much shorter, more compact and lighter. At the same time, mirror-lens systems are expensive and turn out to be rather fragile (however, the latter can be partly compensated for by a rubberized housing and other methods of shock protection). Spyglasses of this type are relatively rare, it is believed that they are better suited for observations at high magnification (including for use as an impromptu telescope).

Field of view 1 km away

The field of view of the telescope at a distance of 1 km to the objects under consideration, the so-called "linear field of view". In fact, this is the width (diameter) of the space that falls into the field of view when observed from a distance of 1 km.

This parameter is widely used in the characteristics of telescopes along with the angular field of view (see below): the linear field of view data is more visual and closer to practice, it allows you to evaluate the capabilities of a telescope without resorting to special calculations.

For models of variable magnification (the majority of them), the linear field of view is indicated in the form of two numbers — for the minimum and for the maximum magnification.

Angle of view

Angle of view provided by a telescope.

If you draw two lines from the centre of the lens to two opposite points along the edges of the field of view of the pipe, the angle between these lines will correspond to the angular field of view. Accordingly, the larger the angle, the wider the field of view; however, individual items in it will look smaller. Conversely, an increase in magnification is inevitably associated with a decrease in the viewing angle. And since most modern telescopes have a variable magnification, the angular field of view is also variable, and in the characteristics this indicator is indicated in the form of two numbers — for the minimum and for the maximum magnification.

Min. focus distance

The smallest distance to the object under consideration at which the telescope is able to fully focus on it — that is, the minimum distance at which the image in the eyepiece will remain clear.

Spotting scopes were originally designed for viewing distant objects, so focus problems can occur if the distance is too small. Thus, manufacturers indicate this parameter in the characteristics. However, even in the most powerful and "long-range" models, the minimum focus distance is about 25 m — at this distance, the naked eye is often enough. Therefore, you should pay attention to this parameter only in cases where the ability to work normally close is of fundamental importance — for example, if the pipe is used at a shooting range, where the distance to the targets can be different, including pretty small.

Lens diameter

The diameter of the objective is the front lens of the telescope. The term "aperture" is also used for this characteristic.

The lens diameter is one of the most important characteristics of an optical system: the amount of light entering the lens and, accordingly, the image quality (especially in low light) directly depend on the aperture. From the point of view of optical characteristics, we can definitely say that the larger the lens, the better, especially at high magnification (for more details, see “Exit Pupil Diameter”). On the other hand, large lenses significantly affect the size, weight, and most importantly, the cost of telescopes. Therefore, manufacturers usually choose the lens size taking into account the magnification, price category and the specifics of the use of a telescope — especially since at low magnifications and good lighting, even a relatively small aperture may well provide a high-quality image. For more information about these patterns, see "Exit Pupil Diameter". In addition, it is worth noting that the features of the "picture" are affected not only by the mathematical characteristics of the optics, but also by the overall quality of its components.

Exit pupil diameter

Exit pupil diameter of a spyglass.

The exit pupil is the projection of the image "seen" by the tube that appears just behind the eyepiece. A person sees an image in a telescope precisely due to the fact that the exit pupil is projected onto the eye.

The exit pupil diameter corresponds to the size of the lens divided by the magnification (see above for both). For example, for a pipe with an aperture of 50 mm, operating at a magnification of 25x, this size will be 50/25 = 2 mm. At the same time, it is believed that in order to ensure the most bright and comfortable image, the exit pupil should be no smaller than the pupil of the observer's eye — and this is 2-3 mm in the light and up to 8 mm (in the elderly — up to 5-6 mm) at dusk. This is the reason why for comfortable work at high magnifications and/or in low light conditions, a telescope must have a fairly large lens. However, most of these optical devices are designed for daytime use, and for this, an exit pupil of 1.33 mm in size is sufficient.

For most modern telescopes, the exit pupil diameter is indicated by two numbers — for the minimum and for the maximum magnification.

Eye relief

Removal of the exit pupil of a telescope.

About the exit pupil itself, see above. Here we note that the offset is such a distance from the eyepiece lens to the observer's eye, at which the size of the visible image from the lens corresponds to the visible size of the eyepiece lens. In other words, the observed "image" in this case occupies the entire space of the eyepiece, without vignetting (darkening at the edges) and without "spreading" beyond the edges of the eyepiece. In this case, the overall image quality will be the best.

When looking down the pipe with the naked eye, the observer usually has no problem getting into the offset distance, and this parameter can be ignored. Problems can arise if the user wears glasses and the diopter adjustment (see above) is not sufficient to comfortably view without glasses. In such cases, it is desirable to use models with eye relief of at least 15 mm: although such a distance will not provide the highest image quality when viewed with glasses, it will allow using the device without any special difficulties. However, in modern telescopes, this parameter can reach 18 mm or even more.

Also note that eye relief may decrease somewhat with increasing magnification; in such cases, two numbers are indicated in the characteristics, corresponding to the removal at the minimum and at the maximum magnification.

Nitrogen filled

The presence in the design of the pipe of a sealed casing filled with an inert gas(most often nitrogen).

This design is somewhat more expensive than a conventional leaky case with air access, but it has a number of important advantages. Firstly, dust does not get inside the case, and the gas is almost perfectly transparent, which contributes to the formation of a high-quality image. Secondly, the gas does not react with the internal metal parts of the instrument (and does not contain water vapor to react). Thirdly, the absence of water vapor prevents lenses from fogging up from the inside. Fourthly, such devices can easily endure staying in conditions of high humidity (for example, outdoors in foggy or rainy weather), and some of them are able to endure even short-term immersion under water. However, in fairness it should be noted that dust and water protection (see below) can also be provided by models without gas filling.
Celestron C90 Mak often compared
Celestron Ultima 100/45 often compared