Comparison Viessmann Vitopend 100-W A1JB 24 kW 24 kW vs Buderus Logamax U072-24K 24 kW

Add to comparison
Viessmann Vitopend 100-W A1JB 24 kW 24 kW
Buderus Logamax U072-24K 24 kW
Viessmann Vitopend 100-W A1JB 24 kW 24 kWBuderus Logamax U072-24K 24 kW
Outdated Product
from $598.21 up to $732.09
Outdated Product
User reviews
0
1
0
3
TOP sellers
Main
DHW capacity at Δt=30° – 11.2 L/min. Resistant to mains voltage fluctuations. Built-in weekly timer. Ability to work with liquefied gas.
DHW capacity at Δt=30° - 11.4 L/min, at Δt=50° - 6.8 L/min. A light weight. Frost protection. Resistant to mains voltage fluctuations. Ability to work with liquefied gas.
Energy sourcegasgas
Installationwallwall
Typedual-circuit (heating and DHW)dual-circuit (heating and DHW)
Heating area192 m²192 m²
Technical specs
Heat output24 kW24 kW
Min. heat output7.2 kW
Power supply230 V230 V
Power consumption120 W150 W
Coolant min. T40 °С40 °С
Coolant max. T80 °С82 °С
Heating circuit max. pressure3 bar3 bar
DHW circuit max. pressure10 bar10 bar
Consumer specs
DHW min. T35 °С40 °С
DHW max. T57 °С60 °С
"Summer" mode
Circulation pump
Control busOpenThermOpenTherm
Programmable thermostat
Boiler specs
Efficiency91 %93.2 %
Combustion chamberclosed (turbocharged)closed (turbocharged)
Flue diameter60/100 mm60/100 mm
Inlet gas pressure16 mbar
Max. gas consumption2.77 m³/h2.8 m³/h
Expansion vessel capacity6 L8 L
Expansion vessel pressure1 bar0.5 bar
Heat exchangerstainless steelcopper
Connections
Mains water intake1/2"1/2"
DHW flow1/2"1/2"
Gas supply3/4"3/4"
Central heating flow3/4"3/4"
Central heating return3/4"3/4"
Safety
Safety systems
gas pressure drop
water overheating
flame loss
draft control
 
gas pressure drop
water overheating
flame loss
draft control
frost protection
More specs
Dimensions (HxWxD)725x400x340 mm700x400x299 mm
Weight32 kg34 kg
Added to E-Catalogaugust 2017december 2014

Min. heat output

The minimum heat output at which the heating boiler can operate in constant mode. Operation at minimum power allows you to reduce the number of on-and-off cycles that adversely affect the durability of heating boilers.

Power consumption

The maximum electrical power consumed by the boiler during operation. For non-electric models (see Energy source), this power is usually low, as it is required mainly for control circuits and it can be ignored. Regarding electric boilers, it is worth noting that the power consumption in them is most often somewhat higher than the useful one since part of the energy is inevitably dissipated and not used for heating. Accordingly, the ratio of useful and consumed power can be used to evaluate the efficiency of such a boiler.

Coolant max. T

The maximum operating temperature of the heat medium in the boiler system when operating in heating mode.

DHW min. T

The minimum temperature of domestic hot water (DHW) supplied by a dual-circuit boiler. For comparison, we note that water begins to be perceived as warm, starting from 40 °C, and in centralized hot water supply systems, the temperature of hot water is usually about 60 °C (and should not exceed 75 °C). At the same time, in some boilers, the minimum heating temperature can be only 10 °C or even 5 °C. A similar mode of operation is used to protect pipes from freezing during the cold season: the circulation of water with a positive temperature prevents the formation of ice inside and damage to the circuits.

It is also worth keeping in mind that when heated to a given temperature, the temperature difference ("ΔT") may be different — depending on the initial temperature of the cold water. And the performance of the boiler in the DHW mode directly depends on ΔT; see below for performance details.

DHW max. T

The maximum temperature of domestic hot water supplied by a dual-circuit boiler. For comparison, we note that water begins to be perceived as warm, starting from 40 °C, and in centralized hot water supply systems, the temperature of hot water is usually about 60 °C (and should not exceed 75 °C). Accordingly, even in the most modest models, this figure is about 45 °C, in the vast majority of modern boilers, it is not lower than 50 °C, and in some models, it can even exceed 90 °C.

Also when heated to a given temperature, the temperature difference ("ΔT") may be different — depending on the initial temperature of the cold water. And the performance of the boiler in the DHW mode directly depends on ΔT; see below for performance details.

Programmable thermostat

The presence of a programmable thermostat in the design of the boiler.

Programmable thermostat is a device that allows not only to maintain the temperature but also to programme the operation of the boiler for a certain time. The simplest programmable thermostats cover a day, and more advanced ones allow you to set the operating mode for individual days of the week. Anyway, this function provides additional convenience and eliminates the need to adjust the operation of the boiler manually. On the other hand, the presence of a programmable thermostat affects the cost.

Efficiency

The efficiency of the boiler.

For electric models (see "Energy source"), this parameter is calculated as the ratio of net power to consumed; in such models, indicators of 98 – 99% are not uncommon. For other boilers, the efficiency is the ratio of the amount of heat directly transferred to the water to the total heat amount released during combustion. In such devices, the efficiency is lower than in electric ones; for them, a parameter of more than 90% is considered good. An exception is gas condensing boilers (see the relevant paragraph), where the efficiency can even be higher than 100%. There is no violation of the laws of physics here. It is a kind of advertising trick: when calculating the efficiency, an inaccurate method is used that does not take into account the energy spent on the formation of water vapour. Nevertheless, formally everything is correct: the boiler gives out more thermal energy to the water than is released during the combustion of fuel since condensation energy is added to the combustion energy.

Inlet gas pressure

It is the optimum gas pressure supplied to the inlet of the boiler system. Most often indicated for natural gas and is about 15-20 mbar. This parameter must match the specs of the gas supply system. However, the pressure in the latter may be higher, which may require the installation of a special gas regulator.

Max. gas consumption

Maximum gas consumption in the boiler with the corresponding energy source (see above). Achieved when the gas heater is operating at full capacity; with reduced power and consumption, respectively, will be lower.

Note that boilers of the same power may differ in gas consumption due to the difference in efficiency. While the more fuel-efficient models tend to cost more, the price difference pays off in gas savings.