Dark mode
United Kingdom
Catalog   /   Computing   /   Components   /   Computer Cooling

Comparison Deepcool GAMMAXX L240 V2 vs Deepcool GAMMAXX L240

Add to comparison
Deepcool GAMMAXX L240 V2
Deepcool GAMMAXX L240
Deepcool GAMMAXX L240 V2Deepcool GAMMAXX L240
Compare prices 1
from £108.49 
Outdated Product
TOP sellers
Main
Heat sink up to 250W. Leak protection Anti-leak Tech. Two quiet 12 cm fans. RGB backlight.
Main specs
Featuresfor CPUfor CPU
Product typeliquid coolingliquid cooling
Max. TDP250 W
Fan
Number of fans22
Fan size120 mm120 mm
Bearinghydrodynamichydrodynamic
Min. RPM500 rpm500 rpm
Max. RPM1800 rpm1800 rpm
Speed controllerauto (PWM)auto (PWM)
Max. air flow69.34 CFM69.34 CFM
Static pressure2.42 mm H2O2.42 mm H2O
replaceable
Min noise level18 dB19 dB
Noise level30 dB30 dB
Power source4-pin4-pin
Radiator
Heatsink materialaluminiumaluminium
Socket
AMD AM2/AM3/FM1/FM2
AMD AM4
Intel 1150
Intel 1155/1156
Intel 1366
Intel 2011 / 2011 v3
Intel 2066
Intel 1151 / 1151 v2
Intel 1200
AMD AM2/AM3/FM1/FM2
AMD AM4
Intel 1150
Intel 1155/1156
Intel 1366
Intel 2011 / 2011 v3
Intel 2066
Intel 1151 / 1151 v2
Intel 1200
Liquid cooling system
Heatsink size240 mm240 mm
Pump size91x79x47 mm91x79x47 mm
Pump rotation speed2400 rpm2550 rpm
Pipe length310 mm310 mm
Pump power source3-pin
General
Lighting
Lighting colourARGBRGB
Lighting syncmulti compatibilitymulti compatibility
Mount typebilateral (backplate)bilateral (backplate)
Manufacturer's warranty3 years3 years
Dimensions282x120x27 mm274x120x27 mm
Weight1293 g1204 g
Added to E-Catalogmay 2019september 2018

Max. TDP

The maximum TDP provided by the cooling system. Note that this parameter is indicated only for solutions equipped with heatsinks (see "Type"); for separately made fans, the efficiency is determined by other parameters, primarily by the air flow values (see above).

TDP can be described as the amount of heat that a cooling system is able to remove from a serviced component. Accordingly, for the normal operation of the entire system, it is necessary that the TDP of the cooling system is not lower than the heat dissipation of this component (heat dissipation data is usually indicated in the detailed characteristics of the components). And it is best to select coolers with a power margin of at least 20 – 25% — this will give an additional guarantee in case of forced operation modes and emergency situations (including clogging of the case and reduced air exchange efficiency).

As for specific numbers, the most modest modern cooling systems provide TDP up to 100 W, the most advanced — up to 250 W and even higher.

Min noise level

The lowest noise level produced by the cooling system during operation.

This parameter is indicated only for those models that have capacity control and can operate at reduced power. Accordingly, the minimum noise level is the noise level in the most “quiet” mode, the volume of work, which this model cannot be less than.

These data will be useful, first of all, to those who are trying to reduce the noise level as much as possible and, as they say, “fight for every decibel”. However, it is worth noting here that in many models the minimum values are about 15 dB, and in the quietest — only 10 – 11 dB. This volume is comparable to the rustling of leaves and is practically lost against the background of ambient noise even in a residential area at night, not to mention louder conditions, and the difference between 11 and 18 dB in this case is not significant for human perception. A comparison table for sound starting from 20 dB is given in the "Noise level" section below.

Pump rotation speed

The speed at which the working part of the pump rotates, which is nominally provided in the water cooling system.

High speed, on the one hand, has a positive effect on performance, on the other hand, it increases the noise level and reduces the time between failures. Therefore, with the same performance, relatively “slow” pumps are considered more advanced, in which the necessary pumping volumes are achieved due to the large diameter of the working part, and not due to speed.

Pump power source

Type of power connector for the water pump.

3-pin. The three-pin power connector on older motherboards does not allow you to control the speed of the water pump motor in liquid cooling systems. At the same time, the pump always works in the maximum performance mode. Fresh "motherboards" are able to change the voltage on such connectors, thereby providing a change in engine speed.

4-pin. When using a 4pin power connector, it is supposed to control the speed of the pump motor using pulse-width modulation. A voltage of 12 V is applied to it with pulses. By changing the duration of the pulses, you can accurately set the speed of the water pump motor.

SATA. The SATA power connector will come in handy if all free 3pin and 4pin connectors are occupied on the motherboard.

Lighting colour

The colour of the backlight installed in the cooling system.

See above for more details on the backlight itself. Also note here that in the illumination of modern cooling systems there is both one colour (most often red or blue, less often green, yellow, white or purple), and multi-colour systems such as RGB and ARGB. The choice of a single-colour backlight depends mainly on aesthetic preferences, but the last two varieties should be touched upon separately.

The basic principle of operation of both RGB and ARGB systems is the same: the design provides for a set of LEDs of three basic colours — red (Red), green (Green) and blue (Blue), and by changing the number and brightness of the included LEDs, you can not only intensity, but and tint of light. The difference between these options differs in functionality: RGB systems support a limited set of colours (usually up to one and a half dozen, or even less), while ARGB allows you to choose almost any shade from the entire available colour range. At the same time, both of them can support backlight synchronization (see below); in general, this function is not required for RGB and ARGB systems, but it is used almost exclusively in them.

Dimensions

General dimensions of the cooling system. For water systems (see "Type"), this paragraph indicates the size of the external radiator (the dimensions of the water block in such devices are small, and there is no need to specify them in particular).

In general, this is a fairly obvious parameter. We only note that for case fans (see ibid.), the thickness is of particular importance — it directly depends on how much space the device will take up inside the system unit. At the same time, it is customary to refer to fans with a thin case for models in which this size does not exceed 20 mm.
Deepcool GAMMAXX L240 V2 often compared