United Kingdom
Catalog   /   Computing   /   Components   /   Computer Cooling

Comparison Deepcool RF140 2 in 1 vs Deepcool CF 140 2pcs.

Add to comparison
Deepcool RF140 2 in 1
Deepcool CF 140 2pcs.
Deepcool RF140 2 in 1Deepcool CF 140 2pcs.
from £46.75 
Outdated Product
from £53.87 
Outdated Product
TOP sellers
Main specs
Featuresfor casefor case
Product typefanfan
Fan
Number of fans22
Fan size140 mm140 mm
Fan thickness25 mm26 mm
Bearinghydrodynamichydrodynamic
Min. RPM500 rpm
Max. RPM1200 rpm1200 rpm
Speed controllerauto (PWM)auto (PWM)
Max. air flow64.13 CFM64.13 CFM
Lighting
Lighting colourRGBRGB
Lighting syncmulti compatibilitymulti compatibility
Min noise level20 dB
Noise level24 dB24 dB
General
Power source4-pin4-pin
Mount typeboltsbolts
Dimensions140x140x25 mm140x140x26 mm
Weight400 g198 g
Added to E-Catalogjanuary 2020april 2019

Fan thickness

This parameter must be considered in the context of whether the fan will fit into the computer case. Standard case fans are available in the order of 25 mm in thickness. Low-profile coolers with a thickness of about 15 mm are designed for small-sized cases, where saving space is extremely important. Fans of large thickness (30-40 mm) boast high cooling efficiency due to the increased impeller dimensions. However, they are noisier than standard models at the same speed and do not always fit into the case normally, sometimes touching other components.

Min. RPM

The lowest speed at which the cooling fan is capable of operating. Specified only for models with speed control (see below).

The lower the minimum speed (with the same maximum) — the wider the speed control range and the more you can slow down the fan when high performance is not needed (such a slowdown allows you to reduce energy consumption and noise level). On the other hand, an extensive range affects the cost accordingly.

Min noise level

The lowest noise level produced by the cooling system during operation.

This parameter is indicated only for those models that have capacity control and can operate at reduced power. Accordingly, the minimum noise level is the noise level in the most “quiet” mode, the volume of work, which this model cannot be less than.

These data will be useful, first of all, to those who are trying to reduce the noise level as much as possible and, as they say, “fight for every decibel”. However, it is worth noting here that in many models the minimum values are about 15 dB, and in the quietest — only 10 – 11 dB. This volume is comparable to the rustling of leaves and is practically lost against the background of ambient noise even in a residential area at night, not to mention louder conditions, and the difference between 11 and 18 dB in this case is not significant for human perception. A comparison table for sound starting from 20 dB is given in the "Noise level" section below.

Dimensions

General dimensions of the cooling system. For water systems (see "Type"), this paragraph indicates the size of the external radiator (the dimensions of the water block in such devices are small, and there is no need to specify them in particular).

In general, this is a fairly obvious parameter. We only note that for case fans (see ibid.), the thickness is of particular importance — it directly depends on how much space the device will take up inside the system unit. At the same time, it is customary to refer to fans with a thin case for models in which this size does not exceed 20 mm.