Dark mode
United Kingdom
Catalog   /   Large Appliances   /   Water Coolers

Comparison HotFrost D65EN vs AEL TD-AEL-340

Add to comparison
HotFrost D65EN
AEL TD-AEL-340
HotFrost D65ENAEL TD-AEL-340
Outdated ProductOutdated Product
TOP sellers
Installationdesktopdesktop
Water loadingtoptop
Features
Water temperature
hot
cold
hot
cold
Cooling typethermoelectric (Peltier)thermoelectric (Peltier)
Cold water tank volume0.6 L
Hot water tank volume1 L
Cooling performance0.6 L/h0.7 L/h
Heating performance4 L/h5 L/h
Heating power420 W500 W
Cooling power80 W68 W
More specs
Water supply controlcup pressurecup pressure
Dimensions (WxDxH)27.3х41.1х30 cm31x33x43 cm
Weight4 kg
Color
Added to E-Catalogjanuary 2018may 2017

Cold water tank volume

The volume of the cold water tank provided in the device.

In this case, it means a tank for water specially cooled by the device (see "Water supply"). The volume of the tank is the maximum amount of cold water that the cooler can dispense in one run, without interruption or with minimal interruptions. When this amount is exhausted, you will have to wait until the water in the tank cools down again to a sufficient degree; the waiting time depends on the cooling capacity (see below). At the same time, the volume of cold water tanks in modern devices is usually several litres, and it is extremely rare to drain this entire volume; usually, small portions of 200-300 mL are required. Therefore, this tank plays the role of a buffer — when the user drains the next portion of water, water from a bottle or a water mains is added to the tank; such an admixture does not particularly affect the temperature in the tank, however, for an additional guarantee, the cooling system immediately turns on. Thus, if consumption does not exceed productivity.

Hot water tank volume

The volume of the hot water tank provided in the device.

This parameter describes the maximum amount of hot water that the cooler can produce in one run, without interruption or with minimal interruptions. When this amount is exhausted, you will have to wait until the water in the tank heats up again to a sufficient degree; the waiting time depends on the heating capacity (see below). At the same time, the volume of hot water tanks in modern devices is usually several litres, and it is extremely rare to drain this volume entirely — usually, small portions of 200-300 mL are required. Therefore, this tank plays the role of a buffer — when the user drains the next portion of water, water from a bottle or a water mains is added to the tank; such an admixture does not particularly affect the temperature in the tank, however, for an additional guarantee, the heating system immediately turns on. Thus, if the consumption does not exceed the heating capacity, the temperature of the contents remains practically unchanged.

Cooling performance

The performance of the cooling system installed in the device, in other words, is the amount of water that can be cooled per hour. In coolers, it is usually indicated for water at room temperature — about 20 °C, in models with a connection to the water mains (see "Water loading") — for 15 °C (this is the average temperature of cold water). Accordingly, when deviating from these indicators, the actual performance may be slightly more or less (however, such deviations must be very significant for this to become noticeable).

This parameter determines two main points. First of all, it characterizes the maximum flow of cold water that the device can handle and the recommended breaks between use. For example, if a user needs to collect 2 standard 200-gram cups and the cooler specifications state a cooling capacity of 2 L/h, this means that the cooler will cool 400 g (0.4 L) of water that has entered the tank, for 0,4/2 = 0.2 h, that is about 12 minutes. However, the need for such calculations arises mainly with high water consumption, which is very close to the claimed performance.

Also, knowing the cooling rate and the volume of the cold water tank (see above), you can determine how long it will take to cool the tank filled with water at room temperature. Such situations arise during the first use of the device, as well as when draining the entire volume of the reservoir. So, if in the above example, the volume of the tank is 3 litres, then 3/2 = 1.5 hours...will be spent on cooling it. However, you can use water earlier, if a slightly elevated temperature is not critical.

Heating performance

The performance of the heating system installed in the device, in other words, is the amount of water that can be heated per hour. In coolers, it is usually indicated for water at room temperature — about 20 °C, in models with a connection to the water mains (see "Water loading") — for 15 °C (this is the average temperature of cold water). Accordingly, when deviating from these indicators, the actual performance may be slightly more or less (however, such deviations must be very significant for this to become noticeable).

This parameter determines two main points. First of all, it characterizes the maximum consumption of hot water that the device can handle and the recommended breaks between use. For example, if a user needs to fill 2 tea cups with a volume of 300 mL each, and the cooler specifications state a heating capacity of 3 L/h, this means that 600 g (0.6 L) of water that has entered the tank instead of poured out, the cooler will heat in 0.6/3 = 0.2 h, that is, about 12 minutes. However, the need for such calculations arises mainly with high water consumption, which is very close to the claimed performance.

Also, knowing the heating rate and the volume of the cold water tank (see above), you can determine how long it will take to heat the tank filled with water at room temperature (for example, if the cooler is started for the first time, or if the tank was completely drained before). So, if in the above example, the volume of the tank is 1 li...tre, then 1/3 hour will be spent on heating it, that is, about 20 minutes. However, you can use water earlier if maximum heating is not critical.

Heating power

It is the power consumed by the device in water heating mode. Usually, it is the operating power of the heating element.

This parameter is directly related to the heating performance (see above): a high heating rate inevitably requires appropriate power. Also, the power consumption of the device depends on this parameter. However, it is worth noting that after the end of heating, the device switches to the temperature maintenance mode and requires much less energy. In other words, the heater consumes the specified power not constantly but occasionally, as needed.

It is also worth mentioning that in models that work only for heating, this indicator also describes the maximum power consumption of the entire device. And, if there are two modes (heating and cooling), the total maximum power consumption corresponds to the sum of the powers of both modes.

Cooling power

It is the power consumed by the device in water cooling mode. In other words, this is the power required for the operation of all elements of the cooling system — a compressor or a converter with a fan (depending on the type of cooling, see above).

This parameter is directly related to the cooling performance (see above): a high cooling rate inevitably requires appropriate power. However, with the same power, compressor systems are more performant than electronic ones. Only models with coolers of the same type can be compared in terms of power.

Also note that the cooling system does not consume this power constantly, but only when necessary. So, at room temperature of the water in the "cold" tank, it turns on at full capacity, and when the desired temperature is reached, it switches to its maintenance mode, which requires much less energy.

In cooling-only models, this figure describes the maximum power consumption of the entire device. And, if there are two modes (heating and cooling), the total maximum power consumption corresponds to the sum of the powers of both modes.
HotFrost D65EN often compared