Kronwerk KB 3500 94692
FUBAG BS 3300
Kronwerk KB 3500 94692FUBAG BS 3300
Outdated ProductOutdated Product
TOP sellers
Fuelpetrolpetrol
Output voltage230 B230 B
Rated power3 kW3 kW
Max. power3.5 kW3.3 kW
Alternatorsynchronoussynchronous
Alternator windingcopper
Engine
ICE type4-stroke4-stroke
Motor typeFUBAG GF210
Engine size212 cm³
Power7 hp5.8 hp
Launch typemanualmanual
Fuel consumption
1.15 L/h /at 75% load/
Fuel tank volume15 L15 L
Fuel level indicator
Motor coolingairair
Connection (sockets)
Total number of sockets22
Sockets 230 V16 A x2
Features
Functions
 
 
 
voltmeter
automatic voltage regulator (AVR)
display
hour metre
voltmeter
General
Protection levelIP 23
Noise level94 dB
97 dB /LWA; 74 dB — at 7 m (LpA)/
Dimensions589x430x432 mm600x450x460 mm
Weight38 kg46.5 kg
Added to E-Catalogfebruary 2018december 2014

Max. power

The maximum power supply that the generator can provide.

This power is slightly higher than the rated power (see above), but the maximum performance mode can only be maintained for a very short time - otherwise overload occurs. Therefore, the practical meaning of this characteristic is mainly to describe the efficiency of the generator when operating with increased starting currents.

Let us remind you that some types of electrical appliances at the moment of startup consume many times more power (and, accordingly, power) than in normal mode; this is typical mainly for devices with electric motors, such as power tools, refrigerators, etc. However, increased power for such equipment is needed only for a short time; normal operation is restored in just a few seconds. And you can evaluate the starting characteristics by multiplying the rated power by the so-called starting coefficient. For one type of equipment it is more or less the same (1.2 - 1.3 for most power tools, 2 for a microwave, 3.5 for an air conditioner, etc.); More detailed data is available in special sources.

Ideally, the maximum power of the generator should be no lower than the total peak power of the connected load - that is, the starting power of equipment with a starting factor above 1 plus the rated power of all other equipment. This will minimize the likelihood of overloads.

Alternator winding

Copper. Copper winding is typical for advanced class generators. The copper alternator is characterized by high conductivity and low resistance. The conductivity of copper is 1.7 times higher than the conductivity of aluminium, such a winding heats up less, and compounds made of this metal endure temperature drops and vibration loads. Among the disadvantages of the copper winding, one can only note the high cost of the alternator. Otherwise, generators with copper winding have high reliability and durability.

— Aluminium. The aluminium winding of the alternator is typical for low-cost-class generators. The main advantages of aluminium are light weight and low price; otherwise, such a winding is usually inferior to copper counterparts. An oxide film is created on the surface of aluminium, it appears everywhere, even in the places of contact soldering. The oxide film undermines the contacts and does not allow the outer protective braid to securely hold the aluminium conductors.

Motor type

Model name of the engine installed in the generator. Knowing this name, you can, if necessary, find detailed data on the engine and clarify how it meets your requirements. In addition, model data may be needed for some specific tasks, including maintenance and repair.

Note that modern generators are often equipped with branded engines from famous manufacturers: Honda, John Deere, Mitsubishi, Volvo, etc. Such engines are more expensive than similar units from little-known brands, but this is offset by higher quality and/or solid warranty conditions , and in many cases, the ease of finding spare parts and additional documentation (such as manuals for special maintenance and minor repairs).

Engine size

The working volume of the engine in a gasoline or diesel generator (see "Fuel"). Theoretically, more volume usually means more power, but in fact, everything is not so clear. Firstly, the specific power strongly depends on the type of fuel, and in gasoline units, also on the type of internal combustion engine (see above). Secondly, similar engines of the same power can have different volumes, and there is a practical point here: with the same power, a larger engine consumes more fuel, but by itself it can cost less.

Power

The operating power of the engine installed in the generator. Traditionally stated in horsepower; 1 HP approximately equal to 735 watts.

First of all, the rated power of the generator directly depends on this indicator (see above): in principle, it cannot be higher than the engine power, moreover, part of the engine power is spent on heat, friction and other losses. And the smaller the difference between these capacities, the higher the efficiency of the generator and the more economical it is. However high efficiency affects the cost, but this difference can pay off with regular use due to fuel savings.

Fuel consumption

Fuel consumption of a gasoline or diesel generator, and for combined models - when using gasoline (see “Fuel”).

A more powerful engine inevitably means higher fuel consumption; however, models with the same engine power may differ in this indicator. In such cases, it is worth considering that a model with a lower consumption usually costs more, but this difference can pay for itself quite quickly, especially with regular use. In addition, knowing the fuel consumption and tank volume, you can determine how long one refueling will last; Moreover, in inverter models at part load, the actual operating time may be noticeably higher than the theoretical one; for more details, see “Alternator”.

Sockets 230 V

The number of 230 V sockets provided in the design of the generator, as well as the type of connectors used in such sockets.

The type of connector in this case is indicated by the maximum power that is allowed for the outlet - for example, “2 pieces for 16 A”. The most popular options for 230-volt outlets are 16 A, 32 A, and 63 A. We emphasize that amperes in this designation are not the actual power that the generator can produce, but the outlet’s own limitation; the actual power value is usually noticeably lower. Simply put, if, for example, the generator has a 32 A socket, the output power on it will not reach 32 A; and the specific number of amperes will depend on the rated and maximum power of the unit (see above). So, if for our example we take a rated power of 5 kW and a maximum of 6 kW, then to a 230 V outlet such a generator will be able to produce no more than 5 kW / 230 V = 22.7 A standard and 6 kW / 230 V = 27, 3 A at its peak. And if the power has to be divided between several outlets, then it will accordingly be even less.

As for specific types of connectors, the higher the power permissible for the outlet, the higher the requirements for its reliability and quality of protection. In light of this, as a rule, higher power outlets can be connected to lower power plugs (directly or through an adapter), but not vice versa. And if there are several sockets, by their type it i...s possible to estimate with some certainty the distribution of the entire power of the generator between them: between two identical sockets such power is usually divided equally, and more power is allocated to an socket with a larger number of amperes and power. However, specific details on this matter should be clarified separately in each case; It's also worth considering 400V outlets, if available (see below).

Functions

- DC output (DC 12 V). The presence in the generator of an output with direct power and a voltage of 12 V. The main function of this output is to charge car batteries, as well as power devices originally intended for cars (remember, 12 V is the standard voltage of on-board networks in passenger cars).

- USB port for charging. The generator has a USB connector (one or more) for charging various devices. Most modern smartphones and tablets can be charged from USB; this charging method is also found in many other equipment - from cameras and flashlights to electric screwdrivers and radio-controlled models. The standard supply voltage through this connector is 5 V, but the power may vary and should be specified separately.

- Synchronization with a smartphone. Synchronization with a smartphone allows you to control the operation of the generator remotely. Thanks to this, the user does not need to approach the device to, for example, start or stop it. Additionally, synchronization with a smartphone allows you to monitor the parameters of the generated electric power remotely and in real time. On the other hand, this will require a constant connection to the Internet and specialized software that must be installed on your smartphone.

- Autorun (ATS). A function that allows the generator to turn on automatically under...certain conditions, without user action. Autostart is used mainly when using a generator as a backup power source: while the main power is on, the unit is turned off, and if the mains voltage disappears, the ATS starts the engine, and power to the load begins to flow from the generator. Note that the presence of autostart is indicated only if the generator is initially equipped with an ATS electronic unit; models with the ability to connect such a unit are placed in a separate category (see below).

- Connector for the ATS block. A connector that allows you to connect an external autorun unit (ATS) to the generator; The block itself is not included. See above for more details on autorun; We note here that for some users this function is not initially needed, but it may be needed in the future - for example, if the generator is initially used in the construction of a house, and then it is planned to be installed in the same house as a backup power source. In such situations, this configuration option will be optimal: when purchasing the generator itself, you will not have to overpay for the ATS unit, and later, if necessary, you can buy and connect such a unit separately.

- Automatic voltage regulator (AVR). An automatic regulator that allows you to maintain a constant voltage level at the generator output. Such a regulator smoothes out differences arising from changes in engine rotation speed; This is especially important when connecting devices that are sensitive to power stability. It is worth noting that the presence of AVR is practically mandatory for synchronous generators (see “Alternator”), but in other varieties this function is not found: in asynchronous and duplex units it is not applicable in principle, and in inverter units the role of the regulator is played by the inverter itself, and they do not require additional electronics.

Display. Own display mounted on the generator body. As a rule, this is a simple LCD screen that can only display numbers and some special characters. However, even such a screen can display various useful information: voltage, frequency, hour meter data, low fuel level warning, failure messages with error codes, etc. Thanks to this, control becomes more convenient and visual.

- Hour meter. A device that counts the total time that the electric generator engine has worked since it was first turned on. This helps to determine the general wear and tear of the engine and the need for its repair/replacement, which can be useful both when using the device for a long time, and, for example, to assess the quality of the product when purchasing a used electric generator. It is usually impossible to reset the hour meter without serious intervention in the design of the device.

Voltmeter. A device that displays the power voltage output by the generator. The voltmeter can be made in the form of a separate dial scale, or its readings can be displayed on the generator’s own display (see above). In any case, this function allows you to carefully control the operating mode of the unit and reduces the risk that unacceptable voltage will be applied to the load.

- Parallel connection. The presence in the design of the generator of special connectors through which two or more units can be connected to a single electrical network (usually with the help of an additional device). This type of connection is used when one unit is not able to pull the entire load and the connection power exceeds the capabilities of the device itself. Also, a similar scheme has found popularity if one of the units is planned to be used as a backup power source.

- Remote start. Presence in a set of delivery of the generator of the remote control. It is made in the form of a wireless key fob and allows you to turn on/off the device from a distance without going near it.

Protection level

The level of protection provided by the generator housing — namely, the degree of protection of the “hardware” from dust, moisture and foreign objects. It is designated by the IP standard with two numbers, one of which corresponds to protection against solid objects and dust, the second — from moisture, for example, IP24.

According to the level of dust protection (first digit) in modern generators, the following values \u200b\u200bare found:

2 — protection against objects with a diameter of more than 12.5 mm (fingers, etc.);
3 — from objects larger than 2.5 mm (most instruments);
4 — from objects more than 1 mm (almost all tools, most wires);
5 — dustproof (full protection against contact; dust can penetrate inside, but does not affect the operation of the device).

Water protection levels can be as follows:

1 — protection against vertically falling drops of water;
2 — from water drops with a deviation of up to 15 ° from the vertical axis of the device (rain);
3 — from water drops with a deviation of up to 60 ° from the vertical axis of the device (rain with wind);
4 — against splashes from any direction (rain with strong wind);


In general, for indoor use, this indicator does not play a key role, but on the street and in similar conditions (for example, at a construction site), you should make sure that the selected generator is sufficiently protected — or else take additional protection measures.