Comparison Global VIP R 500/100 1 vs Global VOX R 500/95 1

Add to comparison
Global VIP R (500/100 1)
Global VOX R (500/95 1)
Global VIP R 500/100 1Global VOX R 500/95 1
from $8.58 up to $9.49
Outdated Product
from $7.84 up to $10.04
Outdated Product
TOP sellers
Radiator typesectionalsectional
Country of originItalyItaly
Manufacturer's warranty10 years
Technical specs
Materialaluminiumaluminium
Number of sections11
Operating pressure16 bar
Max. pressure24 bar
Burst pressure48 bar
Heat transfer medium volume0.46 L
Heat tranfer medium max. temperature110 °C
Mountingwallwall
Connectionsideside
Pipe centre distance500 mm500 mm
Connection size1"1"
Heat output
195 W /at ?Т=70?С/
193 W
Radiator height590 mm590 mm
Radiator width80 mm80 mm
Radiator depth95 mm95 mm
Weight1.62 kg1.45 kg
Added to E-Catalogfebruary 2016february 2015

Manufacturer's warranty

The manufacturer's warranty period for this model.

Usually, the terms of the warranty provide free rectification, replacement and/or compensation if the radiator fails during the stated period due to manufacturing defects. The greater the guarantee, the higher the quality of the product and the higher its cost (the latter, however, is usually compensated by high reliability). In modern radiators, the warranty period can be up to 10 years.

Note that the end of the warranty does not mean the product will immediately fail: with proper workmanship, the total service life exceeds the warranty significantly.

Operating pressure

Radiator operating pressure.

This term usually means the highest pressure of the heating medium that the radiator can sustain without consequences for an indefinitely long time. Higher rates are also allowed for a short time (see "Maximum pressure"). However, the standard operating pressure in the heating system should not exceed the specs of the radiator; otherwise, the product is likely to be damaged. In general, it is believed that this indicator should be at least 2 bar higher than the actual working pressure in the system — this will give an additional margin of safety in case of emergencies.

Max. pressure

The highest heating medium pressure that the radiator is capable to sustain without consequences during short-term exposure.

This figure is always greater than the operating pressure (see above). It directly shows the resistance of the product to emergencies, primarily the water hammer. Other things being equal, higher maximum pressure means greater strength and reliability — however, such radiators are more expensive.

Burst pressure

The burst pressure of the radiator is the water pressure, upon reaching which the product will inevitably be damaged.

The main practical specs of the radiator are the working and maximum pressure (see above); it is on them that one should focus when choosing. The burst pressure is given in the description mainly for promotional purposes: other things being equal, a higher value means greater reliability and resistance to emergencies.

Heat transfer medium volume

The volume of water or other heating medium required to fill the radiator.

This information is relevant mainly when building an autonomous heating system: it is useful when calculating the total volume of heating medium in the system and related parameters. If the radiator is purchased for use in centralized heating, you can not pay much attention to its internal volume.

Heat tranfer medium max. temperature

The maximum heating medium temperature allowed for a radiator is the highest temperature the product can withstand without consequences for a sufficiently long time.

The maximum temperature for heating systems (both centralized and autonomous) is +95 °С as standard. Thus, most radiators have an upper temperature limit of +110 ... 120 °C — this allows you to withstand such conditions confidently.

Heat output

The rated thermal output of the radiator is the amount of heat given off to the air in normal operation.

When choosing this parameter note that the heat output will depend on the temperature difference at the inlet and outlet to the radiator, as well as on the ambient temperature. The greater the temperature difference and the colder it is around, the more intense the heating will be. Therefore, in the specs, it is customary to indicate heat transfer for certain standard conditions. In particular, the designation according to the European standard EN-442 is very popular, which assumes heating medium temperatures of +75 °С and +65 °С at the inlet and outlet, respectively, as well as an air temperature of +20 °С. Real conditions and the actual heat output of the radiator may differ; therefore, when choosing, it is best to choose a model with a certain margin and compensate for excess power with one or another regulator. As for the actual values, in the most modest models, the heat outputdoes not exceed 750 W, or even 500 W, and in the largest, this figure can reach 3.5 – 4 kW or more.

The choice for this parameter depends primarily on the size and specs of the heated space. The simplest calculation formula is as follows: at least 100 W of thermal power is required per 1 m2 of area. This formula is relevant for standard r...esidential/office premises with ceilings of 2.5 – 3 m, without problems with thermal insulation; for more specific conditions, there are more detailed calculation methods, that can be found in special sources.