United Kingdom
Catalog   /   Climate, Heating, Water Heating   /   Water Supply & Pumps   /   Deep Well Pumps

Comparison Aquatica 777102 vs Vodolej BCPE 0.32-40

Add to comparison
Aquatica 777102
Vodolej BCPE 0.32-40
Aquatica 777102Vodolej BCPE 0.32-40
from $94.28 up to $105.27
Outdated Product
from $132.00
Outdated Product
TOP sellers
Max. performance
2700 L/h /maximum/
3000 L/h /maximum/
Max. head
60 m /maximum/
60 m /maximum/
Specs
Operating principlecentrifugalcentrifugal
Max. immersion depth60 m10 m
Mechanical impurities1500 g/m³
pH value6.5 – 8.5
Suction system
multistage /14 steps/
multistage
Oulet size1"1"
Max. liquid T35 °С35 °С
Motor
Power consumption370 W680 W
Mains voltage230 V230 V
Power cable length1.5 m
General specs
Overheat protection
Overload protection
Country of originUkraineUkraine
Impeller materialtechnopolymertechnopolymer
Dimensions75х859 mm
Weight13 kg
Added to E-Catalogapril 2015march 2015

Max. performance

The maximum amount of water that the pump can deliver from the well per unit of time. The choice for this parameter depends on two main points: the maximum total consumption and productivity of the well.

The maximum total consumption is the amount of water that is necessary for the simultaneous normal operation of all points of water intake in the system. Different types of consumers (washbasins, showers, washing machines, etc.) require different amounts of water; exact values can be found in special tables or instructions for specific models of household appliances. And the total consumption can be calculated by adding the indicators of all points of water intake. As for the productivity of the well, this is the maximum amount of water that the well can produce in a certain time without draining it. This indicator is usually indicated in the documents for the well; if it is unknown, before buying a permanent pump, it is imperative to determine the productivity — for example, by trial pumping with an inexpensive unit.

Accordingly, the performance of the pump should not exceed the productivity of the well, and it should be at least 50% of the maximum total consumption of the connected water supply system. The first rule allows you to avoid draining the pump and the troubles associated with it, and compliance with the second guarantees a normal amount of water even with a rather intensive water intake. And, of course, do not forget that high performance requires high power and affects the cost of the device.

Max. immersion depth

The greatest depth under water at which the pump is capable of operating normally.

The optimal location for the deep well pump is as close to the bottom as possible (no closer than 1 m, but this margin can be ignored in this case). It is worth choosing according to the maximum depth, taking into account the depth of the well and the static water level in it (the distance at which the water mirror is located from the surface of the earth when the pump is turned off). For example, there is a well 50 m deep with a static level of 20 m; thus, the depth to the bottom is 50 – 20 = 30 m, and if you want to lower the pump to the very bottom, the maximum immersion depth must be at least 30 m — otherwise too high water pressure may damage the unit.

Mechanical impurities

The largest amount of mechanical impurities in the pumped water, which the pump can handle normally. When used with dirty water, this parameter should be taken into account along with the maximum particle size (see above): if the impurity content is too high, the pump may fail even if the individual particle size does not exceed the norm.

pH value

The pH value of the pumped liquid for which the pump is designed. This indicator describes the level of acidity of the medium, roughly speaking, how reactive it is to the “acidic” or “alkaline” side: low pH values correspond to an acidic environment, and high pH values are alkaline. Acid and alkaline have different effects on the materials used in the design of various equipment, including pumps. Therefore, when designing parts in direct contact with water, the pH level must be taken into account, and using the pump with unsuitable water is not recommended — this can lead to corrosion, poor water quality and a quick failure of the unit. At the same time, it is worth noting that drinking water wells typically have a pH of 6.5 to 8, and overlapping this range (and even wider) is not a problem. Therefore, this parameter can be called secondary, and in many models, it is not indicated at all.

Power consumption

The power consumed by the pump motor during operation. A more powerful engine can provide more head and performance, but these parameters are not directly related: two models of similar power can differ markedly in practical characteristics. Therefore, this parameter is secondary, and more or less unambiguously it describes only the class of the unit as a whole — powerful engines are typical for high-end performant models. But what this characteristic directly affects is the actual power consumption; and with it, in turn, are connected not only to electricity bills but also connection requirements.

Power cable length

The length of the standard power cable provided in the design of the pump.

Ideally, the length of this cable should not be less than the maximum immersion depth — this will ensure maximum ease of connection: the connection point of the cable to the mains will be above the water (in the best case, even outside the well), and you will not have to worry about insulation. At the same time, for several reasons, many pumps are equipped with rather short cords — about 1.5-2 m, and not long cables; in such cases, it is necessary to use special waterproof equipment.

Overheat protection

To avoid overheating of the engine, deep well pumps are equipped with a special thermal relay. When it detects a heating temperature above the norm, it automatically turns off the motor, preventing it from failing.
Aquatica 77710 often compared