Dark mode
United Kingdom
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Circulation Pumps

Comparison Grundfos UPA 15-120 12 m
3/4"
vs Grundfos UPA 15-90 8 m
3/4"

Add to comparison
Grundfos UPA 15-120 12 m 3/4"
Grundfos UPA 15-90 8 m 3/4"
Grundfos UPA 15-120 12 m
3/4"
Grundfos UPA 15-90 8 m
3/4"
Outdated Product
from $89.52 up to $100.80
Outdated Product
TOP sellers
Main functioncold water pressure boostcold water pressure boost
Designsingle headsingle head
Pump typecentrifugalcentrifugal
Rotor typewetwet
Specs
Max. flow2400 L/h1500 L/h
Max. head12 m8 m
Minimum operating pressure0.2 bar0.2 bar
Max. operating pressure10 bar10 bar
Minimum fluid temperature2 °С2 °С
Max. fluid temperature60 °С60 °С
Features
1 speed
automatic operating mode
1 speed
automatic operating mode
Motor
Max. power consumption200 W118 W
Mains voltage230 V230 V
Shaft arrangementhorizontalhorizontal
Connection
Connection typethreadthread
Inlet/outlet arrangementcoaxiallycoaxially
Inlet3/4"3/4"
Outlet3/4"3/4"
More specs
Pump housing materialcast ironcast iron
Country of brand originDenmarkDenmark
Protection classIP42IP42
Added to E-Catalogapril 2019november 2014

Max. flow

The maximum flow of a pump is the amount of liquid it can pump in a certain amount of time.

Features of choosing the optimal performance option depend primarily on the purpose of the pump (see above). For example, for DHW recirculation models, the pump performance should not exceed the performance of the water heater. If the water heater is capable of delivering 10 litres per minute to the DHW circuit, then the maximum pump performance will be 10*60=600 L/h. The basic formula for calculating the performance of a heating system takes into account the power of the heater and the temperature difference at the inlet and outlet, and for the cold water system — the number of points of water intake. More detailed information about the calculations for each application can be found in special sources, and it is better to entrust the calculations themselves to professionals.

Max. head

The head can be described as the maximum height to which a pump can lift liquid through a vertical pipe without bending or branching. This parameter is directly related to the pressure that the pump produces: 10 m of head approximately corresponds to a pressure of 1 bar (do not confuse this parameter with operating pressure — see more about it below).

The head is one of the key specs for most circulation pumps. Traditionally, it is calculated based on the difference in height between the location of the pump and the highest point of the system; however, this principle is relevant only for units that boost the pressure of cold water(see "Suitable for"). Circulation pumps for heating and DHW work with closed circuits, and the optimal pressure depends on the total hydraulic resistance of the system. Detailed calculation formulas for the first and second cases can be found in special sources.

Max. power consumption

The electrical power consumed by the pump during normal operation and maximum performance.

This indicator directly depends on performance — after all, for pumping large volumes of water, an appropriate amount of energy is needed. And the power depends on two main parameters — electricity consumption and the load on the power grid, which determines the connection rules. For example, pumps with a power of more than 5 kW cannot be connected to ordinary household sockets; more detailed rules can be found in special sources.
Grundfos UPA 15-120 often compared