Comparison Winzel Expert WiFi vs Prana 150

Add to comparison
Winzel Expert WiFi
Prana 150
Winzel Expert WiFiPrana 150
Outdated ProductOutdated Product
TOP sellers
System typedecentralizeddecentralized
Ventilation typerecuperatorrecuperator
Mountingwallwall
Mounting diameter160 mm162 mm
Specs
Minimum air flow (ventilation)15 m³/h
Maximum air flow (ventilation)50 m³/h
Maximum air flow (recuperation)115 m³/h
Number of fan speeds3
Maximum noise level21 dB36 dB
Type of heat exchangerenthalpyplate
Heat exchanger materialceramicscopper
Heat exchanger efficiency92 %91 %
Minimum operating temperature-30 °C
General specs
Remote control
Control via Internet
Display
EC fan
Power consumption in ventilation mode18 W32 W
Power consumption (reheater + ventilation)18 W
Mains voltage230 V230 V
Minimum wall thickness150 mm475 mm
Maximum wall thickness500 mm535 mm
Decorative panel thickness64 mm75 mm
Country of originGermanyUkraine
Weight7.28 kg
Added to E-Catalogmarch 2019january 2019

Mounting diameter

The diameter of the holes intended for connecting air ducts to the ventilation unit. The more performant the air ventilation unit, the more air the ducts must pass and the larger, usually, the mounting holes. For wall-mounted models (see above), this parameter determines the size of the channel that must be drilled into the wall to accommodate the unit.

Minimum air flow (ventilation)

The lowest performance with which the supply-exhaust unit can operate.

For performance in general, see "Maximum air flow". Here we note that it makes sense to indicate the minimum flow only in cases where the amount of air passed can be regulated (see "Number of fan speeds"). And even then, for such models, this parameter is not always given.

Maximum air flow (ventilation)

The highest performance of the air ventilation unit; or, if the air flow control is not provided for in the design, the nominal capacity of the unit.

In this case, air flow refers to the amount of air that the unit can pass through itself per hour. The optimal air flow value for each room is calculated by the formula "room volume multiplied by the air exchange rate"; the air flow must not be lower than this indicator; otherwise, we cannot talk about effective ventilation. The volume is easy to calculate by multiplying the area of the room by the height of the ceilings, and the multiplicity indicates how many times per hour the air in the ventilated space should be updated. It depends on the type and purpose of the room: for example, a multiplicity of 1 is enough for a residential apartment, and at least 4 is required for a pool (there are special tables by which you can determine the multiplicity for each type of room). Thus, for example, for an apartment with a living area of 70 m², a ceiling height of 2.5 m and a kitchen of 9 m² (air exchange rate of at least 2), a duct of at least 70*2.5*1+9*2.5*2=220 m³ (excluding bathroom and toilet, they have their requirements for multiplicity).

It should be noted that a certain flow margin (about 10–15%) will not be superfluous, but it hardly makes sense to chase higher rates — after all, performance requires appropriate power, which, in turn, affects the dimensions, price and...energy consumption of the installation.

Number of fan speeds

The number of speeds at which the fans of the air ventilation unit can operate.

The presence of several speeds allows you to choose the actual performance of the installation, adjusting it to the specifics of the current situation: for example, in a production room, you can reduce the ventilation intensity during the night shift, where there are fewer people than in the daytime. And the more speeds provided in the device (with the same performance range) — the more choice the user has, the easier it is to find the mode that best suits current needs.

Note that if the minimum and maximum of the air flow are indicated in the specs, but the number of speeds is not given, this does not necessarily mean smooth adjustment. On the contrary, most often such models are regulated traditionally, in steps, but for some reason, the manufacturer decided not to specify the number of speeds in the characteristics.

Maximum noise level

The noise level produced by the air ventilation unit in normal operation.

This parameter is indicated in decibels, while the decibel is a non-linear unit: for example, a 10 dB increase gives a 100 times increase in sound pressure level. Therefore, it is best to evaluate the actual noise level using special tables.

The quietest modern ventilation units produce about 27–30 dB — this is comparable to the ticking of a wall clock and allows you to use such equipment without restrictions even in residential premises (this noise does not exceed the relevant sanitary standards). 40dB is the daytime noise limit for residential areas, comparable to average speech volume. 55–60 dB — the norm for offices, corresponds to the level of loud speech or sound background on a secondary city street without heavy traffic. And in the loudest, they give out 75–80 dB, which is comparable to a loud scream or the noise of a truck engine. There are also more detailed comparison tables.

When choosing according to the noise level, it should be taken into account that the noise from the air movement through the ducts can be added to the noise of the ventilation unit itself. This is especially true for centralized systems (see "System"), where the length of the ducts can be significant.

Type of heat exchanger

The type of heat exchanger used in the heat exchanger of the ventilation unit (see "Features").

Plate. The simplest and most common type of heat exchanger is based on the use of metal plates that separate the incoming and outgoing air into narrow channels. Such heat exchangers are inexpensive, do not require an electrical connection and are almost silent. However, a classic plastic or metal heat exchanger has a relatively low efficiency (about 45 – 80%), “blows out” moisture from the room (which may require the use of humidifiers), and in frosty weather ice forms on the plates, and it is necessary to turn off the heat exchanger, letting air in bypassing it (for this, an automatic bypass is often provided). The last two shortcomings are devoid of plate heat exchangers made of cellulose — they do not freeze; moreover, they retain not only heat but moisture in the room, and the efficiency can reach 92%. On the other hand, cellulose heat exchangers are not applicable in swimming pools and other areas with high humidity.

Rotary. Heat exchangers, the operation of which is based on the rotation of a disc of a special design. At the same time, each part of the heat exchanger alternately works to cool the exhaust air and then to heat the supply air. Such a system has a higher efficiency than plate heat exchangers, it is more compact, it returns most of the moisture coming out with the exhau...st air and does not freeze in cold weather. On the other hand, due to the complexity of the design, rotary heat exchangers are more expensive and less reliable, in addition, they require power supply and produce some additional noise (although most often not much).

Enthalpy. The key feature of enthalpy (ceramic) heat exchangers is that they transfer to the supply air not only sensible, but also latent heat of the exhaust air, which is released due to moisture condensation. In addition, the design of such heat exchangers provides for the presence of a special membrane made of cellulose or synthetic fabric - it is this that is responsible for transferring heat and moisture to the supply air, thereby ensuring the maintenance of optimal microclimate parameters. This allows you to achieve impressive efficiency indicators - from 90% and above. The main disadvantage of enthalpy heat exchangers is their high cost due to the complexity of production.

— Tubular. Heat exchanger based on a bundle of thin metal tubes of great length placed in a casing. Usually, outdoor air is supplied through such tubes to the room, and the air from the room on the way out moves between the tubes, transferring heat to them. In such devices, you can achieve a fairly solid efficiency — 70% and above; even though tubular heat exchangers are relatively simple in design and reliable. They appeared relatively recently and, for the most part, have not yet received significant distribution.

Heat exchanger material

The heat transfer efficiency, energy saving indicators and service life of the unit directly depend on the material of the heat exchanger. Most often, heat exchangers of supply and exhaust units are made of the following materials:

- Aluminium. Aluminium is a lightweight metal with good thermal conductivity for efficient heat transfer between air streams. Aluminium heat exchangers quickly respond to temperature changes due to rapid heating and cooling, but just as quickly condense in a humid environment. In addition, aluminium dust particles, when released into the air, pose a potential threat to the human respiratory system.

Cellulose. Heat exchangers made of cellulose are lightweight and extremely inexpensive to manufacture. However, in terms of thermal conductivity and wear resistance, cellulose is an ineffective material and is therefore quite rare. On a separate line, it is important to mention that cellulose tends to absorb unpleasant odors, and its cleaning process does not involve washing or other contact with water.

Ceramics. Ceramics as a material for the manufacture of heat exchangers is valued for its wear resistance and high safety, but the cost of such models is often very high. In terms of heat transfer efficiency, ceramics can be called the “golden mean” - it is capable of quickly accumulating heat, but also retains it well, w...ithout completely releasing it to the supply air. This advantage turns into a disadvantage when recovering cold air during the heating period.

- Copper. Heat exchangers made of copper are characterized by high thermal conductivity - copper accumulates and releases heat best, but also cools down just as quickly. The downside of large temperature changes is the formation of condensation, which at low temperatures leads to freezing and a complete stop of ventilation. To avoid freezing, additional heating is used, and this often leads to increased power consumption. However, copper heat exchangers provide the highest efficiency (over 90%), prevent the formation of viral, fungal and bacteriological air pollutants due to natural antiseptic properties, and withstand many years of use. In terms of their combination of qualities, copper heat exchangers are among the best in their class.

Polystyrene. Some air handling units may use heat exchangers with plates made of plastic, polystyrene and other polymer-based materials. They are lightweight and corrosion resistant, but often have lower thermal conductivity. Another flaw in such materials is that many viruses and bacteria can remain viable for quite a long time on the plastic surfaces of the heat exchanger.

Heat exchanger efficiency

Efficiency of the heat exchanger used in the heat exchanger of the supply and exhaust system (see "Features").

Efficiency is defined as the ratio of useful work to the energy expended. In this case, this parameter indicates how much heat taken from the exhaust air, the heat exchanger transfers to the supply air. The efficiency is calculated by the ratio between the temperature differences: you need to determine the difference between the outdoor air and the supply air after the heat exchanger, the difference between the outdoor and exhaust air, and divide the first number by the second. For example, if at an outside temperature of 0 °С, the temperature in the room is 25 °С, and the heat exchanger produces air with a temperature of 20 °С, then the efficiency of the heat exchanger will be (25 – 0)/(20 – 0)= 25/20 = 80%. Accordingly, knowing the efficiency, it is possible to estimate the temperature at the outlet of the heat exchanger: the temperature difference between the inside and outside must be multiplied by the efficiency and then the resulting number is added to the outside temperature. For example, for the same 80% at an outdoor temperature of -10 °C and an internal temperature of 20 °C, the inflow temperature after the heat exchanger will be (20 – -10)*0.8 + -10 = 30*0.8– 10 = 24 – 10 = 14 °C.

The higher the efficiency, the more heat will be returned to the room and the more savings on heating will be. At the same time, a highly efficient heat e...xchanger is usually expensive. Also note that the efficiency may vary slightly for certain values of the external and internal temperatures, while manufacturers tend to indicate the maximum value of this parameter — accordingly, in fact, it may turn out to be lower than the claimed one.

Minimum operating temperature

The lowest outdoor air temperature at which the ventilation unit can be safely used; more precisely, the minimum inlet air temperature at which the unit can operate normally, without malfunctions, for an indefinitely long time.

It is worth choosing according to this parameter taking into account the climate in which it is planned to use the unit: the device should normally tolerate at least the average winter temperature, and it is best to have some reserve in case of a harsh winter. However, many modern models allow operation at -10 °C and below, and in the most cold-resistant ones, the temperature minimum can reach -35 °C. So choosing a unit for a temperate climate is usually not a problem. Also note that if an installation that is ideally suited for all other parameters cannot cope with low temperatures, the situation can be corrected by using an additional heater at the inlet of the ventilation system.

Note that if the minimum temperature is not indicated in the characteristics, it is best to proceed from the fact that this model requires a temperature not lower than 0 °C. In other words, in cold weather, it is worth using only the equipment for which this possibility is directly stated.
Prana 150 often compared