Comparison Mitsubishi Electric Lossnay VL-50S2-E vs Mitsubishi Electric VL-50ES2-E

Add to comparison
Mitsubishi Electric Lossnay VL-50S2-E
Mitsubishi Electric VL-50ES2-E
Mitsubishi Electric Lossnay VL-50S2-EMitsubishi Electric VL-50ES2-E
Outdated ProductOutdated Product
TOP sellers
Main
Horizontal and vertical installation is allowed. Recuperator. Low power consumption. Quiet operation.
Air flow adjustment. Low noise. Horizontal and vertical mounting methods are allowed.
System typedecentralizeddecentralized
Ventilation typerecuperatorrecuperator
Mountingwallwall
Mounting diameter120 mm120 mm
Specs
Minimum air flow (recuperation)15 m³/h15 m³/h
Maximum air flow (recuperation)51 m³/h54 m³/h
Minimum noise level14 dB15 dB
Maximum noise level37 dB37 dB
Type of heat exchangerplateplate
Heat exchanger materialcellulosecellulose
Heat exchanger efficiency86 %86 %
Minimum operating temperature-20 °C
General specs
Remote control
Power consumption in ventilation mode19 W19 W
Mains voltage230 V230 V
Country of originJapanJapan
Dimensions522x245x168 mm522x245x168 mm
Weight6.2 kg6.2 kg
Added to E-Catalogapril 2019august 2018

Minimum operating temperature

The lowest outdoor air temperature at which the ventilation unit can be safely used; more precisely, the minimum inlet air temperature at which the unit can operate normally, without malfunctions, for an indefinitely long time.

It is worth choosing according to this parameter taking into account the climate in which it is planned to use the unit: the device should normally tolerate at least the average winter temperature, and it is best to have some reserve in case of a harsh winter. However, many modern models allow operation at -10 °C and below, and in the most cold-resistant ones, the temperature minimum can reach -35 °C. So choosing a unit for a temperate climate is usually not a problem. Also note that if an installation that is ideally suited for all other parameters cannot cope with low temperatures, the situation can be corrected by using an additional heater at the inlet of the ventilation system.

Note that if the minimum temperature is not indicated in the characteristics, it is best to proceed from the fact that this model requires a temperature not lower than 0 °C. In other words, in cold weather, it is worth using only the equipment for which this possibility is directly stated.
Mitsubishi Electric VL-50ES2-E often compared