United Kingdom
Catalog   /   Photo   /   Binoculars & Telescopes   /   Microscopes

Comparison Sigeta Neptun vs Sigeta Prize Novum 20x-1280x 2Mp

Add to comparison
Sigeta Neptun
Sigeta Prize Novum 20x-1280x 2Mp
Sigeta NeptunSigeta Prize Novum 20x-1280x 2Mp
Outdated ProductOutdated Product
TOP sellers
Features
children's
 
 
training
Typebiologicalbiological
Operation principleopticoptical-digital
Magnification300 – 1200 x20 – 1280 x
Research method
light field
light field
Lens and eyepiece
Turret3 lenses3 lenses
Lens
 
 
4x, 10x, 40x(s)
achromat
Eyepiece
monocular
 
adjustable tilt
monocular
WF5x, WF16x
45° incline
Design
Object table
stationary
 
mobile
90x96 mm
Drug agent
Focuscoarsecoarse
Backlight
lED /+ mirror/
lED
Top illumination
Bottom illumination
Condensersingle lenssingle lens, NA=0.65, fixed
Diaphragmflatflat
Light filters
Number of megapixels2 MP
Features
 
 
brightness control
photo/video recording
Connection interfaces
 
USB
General
Power source
 
batteries
mains 230 V
batteries /2xAA/
In box
 
accessories and preparations set
 
cover/case
camera /2 Mp/
accessories and preparations set
Barlow lens /2x/
cover/case
Materialmetalmetal
Dimensions280х110х250 mm
Weight1.4 kg1.37 kg
Added to E-Catalogoctober 2017september 2017

Features

General purpose of a microscope.

Nowadays, there are 4 main options for the appointment: children's, educational, laboratory and specialized microscopes. At the same time, different options (at least from the first three) may well be combined in one model — for example, the simplest and most inexpensive educational microscopes may well be positioned as children's, and the most advanced as laboratory ones. Here is a detailed description of the different destinations:

— Children's. The most simple and inexpensive microscopes, designed primarily for children who are taking their first steps in the natural sciences (as well as for other undemanding users who do not need particularly advanced functionality). Accordingly, such devices lack advanced features such as focus lock, Keller lighting, video outputs (for digital and opto-digital models), a trinocular with the ability to connect a camera, etc. In addition, the body can be made in bright colours, and in plastic is usually used as the body material. However, many children's microscopes are equipped with turrets for quick re-tuning of magnification, and the total magnification factor may well exceed 600x out of the box and 1000x in the top configuration.

— Educational. Microscopes well suited for teaching applications; sometimes such an appointment is even di...rectly indicated by the manufacturer. The specific functionality of such models is quite diverse, the type can also be different (both biological and stereoscopic). In general, devices of this specialization occupy an intermediate position between simple and inexpensive children's microscopes and advanced laboratory equipment. At the same time, there are many models that have a combined purpose — "children's / educational" or "training / laboratory". The first variety is simple and inexpensive, for educational purposes it is suitable mainly for school; the second option, in turn, can be useful even at the university faculty of natural sciences.

— Laboratory. The most advanced type of modern microscopes, designed for full-fledged laboratory research and other serious tasks. Accordingly, such models are not cheap, but they provide a high-quality image and, in general, have the most extensive functionality (although the specific set of features, of course, may be different). Among the features found in laboratory microscopes are a movable stage, installation of light filters, 2 types of illumination (lower and upper), Keller illumination, suitability for special microscopy methods (fluorescence, phase contrast), etc.

— Specialized. Microscopes of a specific design and purpose, one way or another different from more traditional models. These differences may vary; accordingly, the specific specialization also differs. So, recently, portable models for smartphones have gained quite significant popularity: with the help of a special clothespin, such a device is attached directly to the gadget opposite the main camera, and the smartphone screen plays the role of an eyepiece. Another popular variety is compact digital microscopes without their own screens, connected to PCs or laptops via USB, and even to smartphones via Wi-Fi (including via the Internet). This also includes professional equipment with a fairly narrow specialization: stereoscopes with special mounts for dental prosthetics, for soldering microcircuits, etc.; microscopes for metallurgical research; devices on a tripod with a remote rod, designed to inspect individual areas on general objects; comparative microscopes for ballistic and trace investigations in forensics; and etc.

Operation principle

Optical. Traditional microscopes, which work based on the use of lenses and other optical elements. They allow you to provide high image quality and a good magnification factor, while they do not depend on electricity (except that batteries may be needed for the backlight system). This type of microscope uses traditional eyepieces, but there are some models that allow you to connect an external camera and display the image on a computer display. Also note that this is the only principle used in stereoscopic models (see "Type")

Digital. Microscopes of this type are actually digital cameras, supplemented with powerful magnifying optics. The image from such a camera must be displayed on the screen; some models have their own displays, others do not have displays and need to be connected to a computer/laptop. The advantage of the first variety is independence from external equipment, the advantages of the second option are compactness and relatively low cost. At the same time, it should be noted that in terms of magnification, most digital microscopes are inferior to optical ones, and this principle is not suitable for a stereoscopic image.

Optical-digital. Microscopes that combine the features of optical and digital models (see relevant paragraphs). Such models differ from "purely digital" devices by more advanced optics, with a revolving head and a...high magnification; from optical ones — with a built-in camera and using a screen as an eyepiece (traditional eyepieces are not used in optical-digital models).

Magnification

The range of magnifications provided by the device is from minimum to maximum.

The magnification of the microscope is calculated by the formula "the magnification of the eyepiece is multiplied by the magnification of the objective." For example, a 20x objective with a 10x eyepiece will give a magnification of 10*20 = 200x. Modern microscopes can be equipped with multi-objective turrets, zoom lenses (see below) and interchangeable eyepieces — so that in most models the magnification can be adjusted. This allows you to adjust the device to different situations: when you need to consider small details, a high degree of magnification is used, but to expand the field of view, the magnification must be reduced.

Detailed recommendations on optimal multiplicities for different tasks can be found in special sources. Here we note that many manufacturers go to the trick and indicate the maximum value of the magnification by the degree of magnification achieved with an additional Barlow lens. Such a lens can indeed give a serious increase in magnification, but it is not a fact that the image will turn out to be of high quality; for more details, see "Complete set".

Lens

Zoom lens. Lens with variable magnification. Such optics allow you to smoothly change the overall magnification of the microscope within certain limits, without changing the objective/eyepiece and without even looking up from observations. On the other hand, zoom lenses are more complicated and more expensive than constant magnification optics. Therefore, they are mainly used in stereoscopic microscopes (see "Type"): in the repair, assembly and other tasks for which such devices are used, the ability to smoothly adjust the multiplicity is extremely useful.

— magnification factor. The magnification provided by the lens. This parameter, along with the magnification of the eyepiece, affects the overall magnification of the device (see above). Most biological microscopes (see "Type") are equipped with several different magnification objectives on the turret; this allows you to adjust the degree of magnification as desired by the user. The standard magnification options for such lenses are 4x, 10x, 40x, 100x.

— Achromat. One of the varieties of colour correction used in lenses. The need for colour correction is due to the fact that light of different colours is refracted differently by lenses, and without additional measures, the image in the microscope would be blurred with iridescent stains. Achromatic is one of the simplest types of colour correction; in such optics, colour distortions in yellow and green are corrected.... Achromatic lenses have simple design and low cost. However the image quality in them is far from perfect: such a lens gives a clear image only in the centre of the image, the width of the sharpness zone is about a third of the total width of the field of view, and red-blue streaks may appear along the edges of the image. However, this is quite enough for general acquaintance, initial training, and often for more serious tasks.

— Planachromat. An improved and improved version of achromatic lenses (see above). Plan achromats provide additional correction of the field curvature, due to which the area of a clearly visible image in such lenses is at least 2/3 of the total width of the field of view, and often even more. It is these lenses that are recommended for serious study and professional use.

— Rim diameter. The size of the thread used to mount the lens. A larger bore usually means a wider lens, which means higher aperture and better image quality. On the other hand, the large size affects the dimensions, weight and cost of optics. In modern microscopes, diameters from 20 to 35 mm are mainly found. Knowing the size of the thread, you can purchase replacement or spare lenses for the device.

Eyepiece

Monocular. An eyepiece with a single lens that can only be viewed with one eye. For obvious reasons, it is only used in biological microscopes (see "Type"). The advantages of monoculars are primarily smaller size and cost than other varieties; in addition, they do not require adjustment for interpupillary distance. On the other hand, constantly looking into the eyepiece with one eye is tiring, so this option is poorly suited for situations where you have to look into the microscope often and for a long time.

Binocular. Dual eyepiece that can be viewed with both eyes at once. Note that such optics are used not only in stereomicroscopes, originally intended for viewing an object through two lenses (see "Type"), but also in biological microscopes with one lens. The fact is that looking into an optical device with two eyes is much more convenient than with one, while the eyes are less loaded and fatigue does not occur so quickly. Therefore, for serious tasks associated with frequent use of a microscope, binoculars (or trinoculars, see below) are the best option. Such optics cost more than monocular, but this is offset by ease of use.

Trinocular. A kind of binocular (see the relevant paragraph), supplemented by a third optical channel for a special camera-video eyepiece. Such a camera is usually connected to a PC or laptop; by installing it in the soc...ket for the third eyepiece, you can take photos and videos, as well as display the image in real time on the computer screen. At the same time, you can look through the microscope in the usual way. Devices with trinoculars are very functional and versatile, but they are complex and expensive.

— LCD screen. The microscope has an LCD screen that replaces the traditional eyepiece. You do not need to bend over to such a device each time to view the image, which is very convenient if observations need to be combined with record keeping and other similar activities. Microscopes of this design usually have a photo and video function, as well as various built-in tools — for example, a scale grid for estimating the size of visible objects, displayed directly on the screen. In addition, the image on the screen can be seen not only by the direct user, but also by everyone who is nearby; such features are indispensable during training sessions, consultations, presentations, etc. On the other hand, such microscopes turn out to be bulky and expensive.

— magnification factor. The magnification provided by the eyepiece. This parameter, along with the lens magnification, affects the overall magnification of the device (see above). The classic option for eyepieces in microscopes is 10x, but higher values \u200b\u200bare also found. The package may include several eyepieces, of different magnification — to change the overall degree of magnification. There is a multiplicity designation with a letter index, for example, WF10x. This means that the eyepiece has an extended field of view (WF — wide, EWF — extra wide, UWF — extra wide).

— Eyepiece tilt. The tilt of the eyepiece determines the position of the observer's head when looking through the microscope and the overall usability. According to this indicator, three main options can be distinguished: fixed angle, adjustable angle, without tilt. The fixed angle is most often 30° or 45° relative to the horizontal, these values are considered the most convenient. In angle-adjustable microscopes, the entire stand, with tube and stage, is fixed to the base with a swivel mount. This is the most convenient option, allowing you to adjust the tilt to your preference, but the mount tends to become loose over time, so it is rarely used in professional microscopes. The third variety — vertical microscopes, without tilt — have not received much distribution: this design is used in some stereoscopic models (see "Type") in order to ensure that the stage remains strictly horizontal (this is important for some work with microscopic objects).

— Rim diameter. The nominal diameter of the eyepiece used in the microscope, as well as the diameter of the hole in the tube, designed to install the eyepiece. Several standard diameters are used in modern microscopes, in particular 23 and 27 mm. In fact, this parameter is necessary, first of all, if you plan to purchase spare or replacement eyepieces for the microscope, or if you already have an eyepiece on the farm, and you need to evaluate its compatibility with this model.

— Diopter adjustment. The range of diopter correction provided in the eyepiece. This correction is used so that a nearsighted or farsighted person can look through the microscope without glasses or contact lenses. In most models with this function, the correction range is about 5 diopters in both directions; this allows the microscope to be used for low to moderate myopia/farsightedness.

Object table

The design of the object stage provided in the microscope.

— Stationary. Subject table, fixed motionless; focus in such microscopes is carried out by moving up and down the tube with the objective and the eyepiece. Such systems are simple and inexpensive, but focus while looking through a constantly moving eyepiece is not very convenient. In addition, for advanced biological microscopes (see "Type") with binoculars and trinoculars (see "Eyepiece"), this option is also poorly suited for some design reasons. But the vast majority of stereomicroscopes are equipped with stationary tables — this is the most reasonable design, taking into account the specifics of the application.

Movable. In microscopes of this type, the entire optical system is fixedly fixed on a tripod, and the stage can be moved up and down to focus the optics. This design is found exclusively in biological microscopes (see "Type"). It is somewhat more complicated and expensive than with a fixed table, but at the same time it is much more convenient: when focus, the eyepiece does not move, which allows you to comfortably adjust the image without looking up. In addition, it is the movable stage that is most suitable for advanced devices with binoculars and trinoculars (see "Eyepiece"), almost all such microscopes have such equipment.

Drug agent

Presence of a preparation agent in the design of the object table.

The preparation guide is a device for smooth movement of slides under the microscope lens, as well as fixing the conditional coordinates of individual sections of the preparation. Mechanisms are responsible for the movement, allowing the glass to be shifted separately in the longitudinal and transverse directions. Coordinate fixation is provided by special scales with verniers, the accuracy of determining coordinates can be from 0.1 to 0.01 mm.

This feature is found exclusively in biological microscopes (see "Type"). Its presence can be extremely important for studies involving high magnification factors. Without a slider, the glass would have to be moved by hand, and finding certain areas would be a very difficult, if not impossible, task.

Top illumination

The presence in the microscope of illumination directed from top to bottom. In biological microscopes (see "Type"), such illumination makes it possible to examine opaque objects; also in some cases it can be used as an addition to the main lower lighting. And in stereoscopic models, only overhead light is used — this is due to the specifics of the application.

Bottom illumination

Bottom lighting is a lighting system, the light from which is directed from the bottom up.

In conventional (not inverted) microscopes, such illumination is directed towards the objective through a hole in the stage. It is this type of illumination that is used for classical bright-field microscopy using through illumination; Thus, the lower arrangement of the illumination is traditional for biological microscopes and is provided for in most of these models. But the presence of this function in "stereoscopes" is not typical, although it also occurs.

In turn, in inverted microscopes, the upper and lower illuminations are actually “swapped”. Accordingly, in such models, this function is intended for examining preparations (mostly opaque) in reflected light, and the light flux is directed from the lens to the preparation.
Sigeta Prize Novum 20x-1280x 2Mp often compared